Verified Specification Summary

Operating at 1.2 gpm, the WINDON BAY, WB FC00340 faucet beats 1992 EPAct rules (2.2 gpm) by 45.5% (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets), saving a 3-resident home ~6,789 gallons annually compared to 2.75 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for WINDON BAY, WB FC00340 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.2 gpm
vs. EPAct 1992
-45.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,752 gal/yr
Annual Saved vs. Legacy
2,263 gal/person
Brand EPA Count
12 faucets
Series / Variants
FC00340 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does WINDON BAY, WB FC00340 Benchmark & Water Budget show?

WaterSense benchmark: WINDON BAY, WB series FC00340 verifies 1.2 gpm delivery, scoring 45.5% leaner than EPAct 1992 (2.2 gpm) at #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets.

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: WINDON BAY, WB holds 12 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as Liberty Utilities - Arizona (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

How much leaner is WINDON BAY, WB FC00340 than pre-1994 2.75 gpm plumbing?

Flow distribution bars contrast WINDON BAY, WB FC00340 (1.20 gpm) directly with the 1.2 gpm WaterSense median and 2.75 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): FC00340: 1.20; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)FC00340: 1.20FC003401.20EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.2 gpm: 1.2 gpm (67th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.2 gpm: 1.2 gpm (P67)

Which framing and flange tolerances matter before installing WINDON BAY, WB FC00340?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does WINDON BAY, WB FC00340 compare to WaterSense category caps?

Each specification row below documents WINDON BAY, WB FC00340 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share WINDON BAY, WB (12 certified) EPA WaterSense Partner
Model Number / Series FC00340 Certified Series (1 finish variants)
Rated Consumption 1.2 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does WINDON BAY, WB FC00340 cut?

Calculated annual water budgets below quantify WINDON BAY, WB FC00340 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for WINDON BAY, WB FC00340 (1.2 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,752 gal1,460 gal2,263 gal (~$25)
2 Occupants3,504 gal2,920 gal4,526 gal (~$50)
3 Occupants5,256 gal4,380 gal6,789 gal (~$54–$122)
4 Occupants7,008 gal5,840 gal9,052 gal (~$100)

Which competing models share WINDON BAY, WB FC00340 flow tier?

Review five peer WaterSense units matching WINDON BAY, WB FC00340 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 LUM211-PU 1.2 gpm (Same flow) Lumoni
Aidier ID-B3594 1.2 gpm (Same flow) WaterSense
Axor 48170xx1 1.2 gpm (Same flow) Axoror One
B&K 221-015 1.2 gpm (Same flow) Lavatory Faucet
B&K 222-311H 1.2 gpm (Same flow) Lavatory Faucet

Can you estimate WINDON BAY, WB FC00340 payback in your home?

Test how many gallons and dollars WINDON BAY, WB FC00340 saves each year by entering your household residents and local water-sewer rate below.

Where should contractors skip WINDON BAY, WB FC00340 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for WINDON BAY, WB FC00340 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Choose this if: Upgrading 2.75 gpm fixtures for 56.4% water reduction
  • Works well for: Matching WINDON BAY, WB SKU FC00340 certification on rebate forms

How do federal and code standards apply to WINDON BAY, WB FC00340?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for WINDON BAY, WB FC00340.

What annual dollar savings can a 3-person home expect with WINDON BAY, WB FC00340?

Upgrading a 4.0 gpm legacy fixture to WINDON BAY, WB FC00340 saves ~24,528 gallons yearly for three occupants, about $270/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with WINDON BAY, WB FC00340?

Pairing WINDON BAY, WB FC00340 (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing WINDON BAY, WB FC00340 require a municipal plumbing permit?

Like-for-like swaps using WINDON BAY, WB FC00340 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How many gallons per person does WINDON BAY, WB FC00340 save annually?

Each resident saves ~8,176 gallons yearly (70.0% drop) replacing a 4.0 gpm fixture with WINDON BAY, WB FC00340 (1.2 gpm), or 2,920 gal/yr versus 2.2 gpm EPAct baselines.

Who should NOT install WINDON BAY, WB FC00340 without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.2 gpm faucet.

Can homeowners claim utility rebates when installing WINDON BAY, WB FC00340?

Because WINDON BAY, WB FC00340 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is WINDON BAY, WB FC00340 leaner than typical WaterSense faucet models?

Compared with the 1.2 gpm WaterSense faucet median, WINDON BAY, WB FC00340's 1.2 gpm rating places it equal to category norms inside EPA conservation limits.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)