Skip to main content
Grant Estimator

Aquacubic AF9106-2 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Aquacubic (1 SKU)
Verified Specification Summary

Operating at 2.0 gpm, the Aquacubic AF9106-2 showerhead beats 1992 EPAct rules (2.5 gpm) by 20.0% (#14,982 of 18,544 certified showerheads; tied with 3,562 other certified showerheads at 2.00 gpm), saving a 3-resident home ~13,140 gallons annually compared to 3.5 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for Aquacubic AF9106-2 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
2.0 gpm
vs. EPAct 1992
-20.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,840 gal/yr
Annual Saved vs. Legacy
4,380 gal/person
Brand EPA Count
26 showerheads
Series / Variants
AF9106-2 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Aquacubic AF9106-2 Benchmark & Water Budget show?

WaterSense benchmark: Aquacubic series AF9106-2 verifies 2.0 gpm delivery, scoring 20.0% leaner than EPAct 1992 (2.5 gpm) at #14,982 of 18,544 certified showerheads; tied with 3,562 other certified showerheads at 2.00 gpm (0.25 gpm higher-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 2.0 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Aquacubic holds 26 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~13,140 gallons/yr—roughly $105/yr in low-tariff towns ($8/1k gal), $145/yr at national averages ($11/1k gal), or $237/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: Alsons 462PB (2.0 gpm) and Aquasource 0799969 (2.0 gpm).

How much leaner is Aquacubic AF9106-2 than pre-1994 3.5 gpm plumbing?

Flow distribution bars contrast Aquacubic AF9106-2 (2.00 gpm) directly with the 1.75 gpm WaterSense median and 3.5 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): AF9106-2: 2.00; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)AF9106-2: 2.00AF9106-22.00EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 2.0 gpm: 2 gpm (100th percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm2.0 gpm: 2 gpm (P100)

Which framing and flange tolerances matter before installing Aquacubic AF9106-2?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does Aquacubic AF9106-2 compare to WaterSense category caps?

Each specification row below documents Aquacubic AF9106-2 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Aquacubic (26 certified) EPA WaterSense Partner
Model Number / Series AF9106-2 Certified Series (1 finish variants)
Rated Consumption 2.0 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does Aquacubic AF9106-2 cut?

Calculated annual water budgets below quantify Aquacubic AF9106-2 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for Aquacubic AF9106-2 (2.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,840 gal1,460 gal4,380 gal (~$48)
2 Occupants11,680 gal2,920 gal8,760 gal (~$96)
3 Occupants17,520 gal4,380 gal13,140 gal (~$105–$237)
4 Occupants23,360 gal5,840 gal17,520 gal (~$193)

Which competing models share Aquacubic AF9106-2 flow tier?

Review five peer WaterSense units matching Aquacubic AF9106-2 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
Alsons 462PB 2.0 gpm (Same flow) WaterSense
Aquasource 0799969 2.0 gpm (Same flow) AMARI
AquaSource 247101 2.0 gpm (Same flow) WaterSense
AquaSource 423868 2.0 gpm (Same flow) WaterSense
Belle Foret HD873W-35 2.0 gpm (Same flow) WaterSense

Can you estimate Aquacubic AF9106-2 payback in your home?

Test how many gallons and dollars Aquacubic AF9106-2 saves each year by entering your household residents and local water-sewer rate below.

Which bath layouts should avoid specifying Aquacubic AF9106-2?

Match Aquacubic AF9106-2 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Best for: Upgrading 3.5 gpm fixtures for 42.9% water reduction
  • Optimal use: Matching Aquacubic SKU AF9106-2 certification on rebate forms

How do federal and code standards apply to Aquacubic AF9106-2?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Aquacubic AF9106-2.

What supply pressure checks protect Aquacubic AF9106-2 spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 2.0 gpm trim.

Does Aquacubic AF9106-2 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Aquacubic AF9106-2 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does Aquacubic AF9106-2 rank against other certified showerheads?

Rated at 2.0 gpm, Aquacubic AF9106-2 measures slightly above the 1.8 gpm WaterSense showerhead median across thousands of EPA-listed residential fixtures.

Does Aquacubic AF9106-2 cut utility costs noticeably for a 3-person household?

Yes: cutting 17,520 gallons/yr relative to 4.0 gpm hardware translates to ~$193/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with Aquacubic AF9106-2?

Pairing Aquacubic AF9106-2 (2.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 2.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Aquacubic AF9106-2 require a municipal plumbing permit?

Like-for-like swaps using Aquacubic AF9106-2 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How does Aquacubic AF9106-2 cut household water draw versus 1992 federal rules?

Delivering 2.0 gpm, Aquacubic AF9106-2 trims 1,460 gal/person/yr below 2.5 gpm EPAct caps (20.0% reduction) and 5,840 gal/person/yr under 4.0 gpm legacy fixtures.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories