Skip to main content
Grant Estimator

BOZYBO 72011 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Shower head (1 SKU)
Verified Specification Summary

Listed in EPA WaterSense files at 1.75 gpm, BOZYBO 72011 achieves #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads and lowers household water use ~15,330 gal/yr (3 residents) against pre-1994 3.5 gpm fixtures. Compare EPA WaterSense certified flow metrics for BOZYBO 72011 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.75 gpm
vs. EPAct 1992
-30.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,110 gal/yr
Annual Saved vs. Legacy
5,110 gal/person
Brand EPA Count
63 showerheads
Series / Variants
72011 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does BOZYBO 72011 Benchmark & Water Budget show?

Certified discharge for BOZYBO 72011 (Shower head) measures 1.75 gpm (balanced WaterSense flow tier), standing #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads against the 2.5 gpm standard.

Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: BOZYBO holds 63 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).

Does BOZYBO 72011 beat the 1.75 gpm WaterSense showerhead median?

Certified at 1.75 gpm, BOZYBO 72011 sits well under EPAct 1992 limits (2.5 gpm) across 18,544 EPA-registered showerheads.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 72011: 1.75; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)72011: 1.75720111.75EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.75 gpm: 1.75 gpm (53rd percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.75 gpm: 1.75 gpm (P53)

Why check closet flange height and L/360 stiffness around BOZYBO 72011?

Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Where does BOZYBO 72011 fit in EPA WaterSense files?

Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for BOZYBO 72011.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share BOZYBO (63 certified) EPA WaterSense Partner
Model Number / Series 72011 Shower head (1 finish variants)
Rated Consumption 1.75 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Does BOZYBO 72011 lower water bills for larger households?

Review computed annual water totals for 1 to 4 residents comparing BOZYBO 72011 certified consumption with older pre-1994 residential plumbing hardware.

Computed annual water savings for BOZYBO 72011 (1.75 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,110 gal2,190 gal5,110 gal (~$56)
2 Occupants10,220 gal4,380 gal10,220 gal (~$112)
3 Occupants15,330 gal6,570 gal15,330 gal (~$123–$276)
4 Occupants20,440 gal8,760 gal20,440 gal (~$225)

How do similar WaterSense brands compare with BOZYBO 72011?

Comparable certified models listed below share BOZYBO 72011 category standards while offering alternative brand warranties and rough-in configurations.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen+roth 5283486 1.75 gpm (Same flow) WaterSense
Axor 38442xx1 1.75 gpm (Same flow) Uno
COBBE KFSCA12102 1.75 gpm (Same flow) KFSCA12102
Current 01932-T 1.75 gpm (Same flow) WaterSense
DORNBRACHT 28.647.970-xx0010 1.75 gpm (Same flow) WaterSense

How do local water rates change BOZYBO 72011 savings?

Use the local browser estimator below with your city water-sewer rate and household size to quantify BOZYBO 72011 yearly utility impact.

What plumbing or duct constraints rule out BOZYBO 72011?

Compare where BOZYBO 72011 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Homeowner profile: Claiming utility rebates across 200 U.S. WaterSense programs
  • Suited to: Lowering household draw to 5,110 gal/person/yr

What should homeowners verify first about BOZYBO 72011?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to BOZYBO 72011.

When can BOZYBO 72011 (1.75 gpm) underperform in an older bathroom?

Skip BOZYBO 72011 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat BOZYBO 72011?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like BOZYBO 72011, itemized purchase invoices, and residential installation addresses.

How does BOZYBO 72011 perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.75 gpm, BOZYBO 72011 sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to BOZYBO 72011?

At $11 per 1,000 gallons, a 3-person household conserving 19,710 gallons/yr with BOZYBO 72011 trims roughly $217 annually off water and sewer utility bills.

What anti-scald valve standard pairs with BOZYBO 72011?

Pairing BOZYBO 72011 (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing BOZYBO 72011 require a municipal plumbing permit?

Like-for-like swaps using BOZYBO 72011 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 4.0 gpm fixture to BOZYBO 72011 at 1.75 gpm?

Swapping a 4.0 gpm unit for BOZYBO 72011 slashes water draw 56.2% (6,570 gal/person/yr), beating 2.5 gpm federal EPAct standards by 30.0%.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories