Listed in EPA WaterSense files at 1.5 gpm, Chicago Faucets 152-ALCP achieves #559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads and lowers household water use ~17,520 gal/yr (3 residents) against pre-1994 3.5 gpm fixtures. Compare EPA WaterSense certified flow metrics for Chicago Faucets 152-ALCP WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.5 gpm
- vs. EPAct 1992
- -40.0% (2.5 gpm)
- Annual Draw (1 Pers.)
- 4,380 gal/yr
- Annual Saved vs. Legacy
- 5,840 gal/person
- Brand EPA Count
- 305 showerheads
- Series / Variants
- 152-ALCP (1)

What does Chicago Faucets 152-ALCP Benchmark & Water Budget show?
Certified discharge for Chicago Faucets 152-ALCP measures 1.5 gpm (aggressive sub-1.6 gpm conservation tier), standing #559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads (0.25 gpm lower-flow than the 1.75 gpm median) against the 2.5 gpm standard.
Verify >=30 PSI static water pressure and pair this 1.5 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.
Brand breadth: Chicago Faucets holds 305 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~17,520 gallons/yr—roughly $140/yr in low-tariff towns ($8/1k gal), $193/yr at national averages ($11/1k gal), or $315/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: Acorn Controls CSH-WSC (1.5 gpm) and ACORN CSH-WSA (1.5 gpm).
Does Chicago Faucets 152-ALCP beat the 1.75 gpm WaterSense showerhead median?
Certified at 1.50 gpm, Chicago Faucets 152-ALCP sits well under EPAct 1992 limits (2.5 gpm) across 18,544 EPA-registered showerheads.
Why check closet flange height and L/360 stiffness around Chicago Faucets 152-ALCP?
Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.
Where does Chicago Faucets 152-ALCP fit in EPA WaterSense files?
Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for Chicago Faucets 152-ALCP.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Chicago Faucets (305 certified) | EPA WaterSense Partner |
| Model Number / Series | 152-ALCP | Certified Series (1 finish variants) |
| Rated Consumption | 1.5 gpm | Category median 1.75 gpm (n=18,544 rated) |
| Shower / Faucet Pairing | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |
Does Chicago Faucets 152-ALCP lower water bills for larger households?
Review computed annual water totals for 1 to 4 residents comparing Chicago Faucets 152-ALCP certified consumption with older pre-1994 residential plumbing hardware.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 4,380 gal | 2,920 gal | 5,840 gal (~$64) |
| 2 Occupants | 8,760 gal | 5,840 gal | 11,680 gal (~$128) |
| 3 Occupants | 13,140 gal | 8,760 gal | 17,520 gal (~$140–$315) |
| 4 Occupants | 17,520 gal | 11,680 gal | 23,360 gal (~$257) |
How do similar WaterSense brands compare with Chicago Faucets 152-ALCP?
Comparable certified models listed below share Chicago Faucets 152-ALCP category standards while offering alternative brand warranties and rough-in configurations.
| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| Acorn Controls CSH-WSC | 1.5 gpm (Same flow) | WaterSense |
| ACORN CSH-WSA | 1.5 gpm (Same flow) | WaterSense |
| Aquacubic ASH8469 | 1.5 gpm (Same flow) | WaterSense |
| California Faucet SH-04T.15 | 1.5 gpm (Same flow) | WaterSense |
| Chi Liu CL-01627-2 | 1.5 gpm (Same flow) | WaterSense |
How do local water rates change Chicago Faucets 152-ALCP savings?
Use the local browser estimator below with your city water-sewer rate and household size to quantify Chicago Faucets 152-ALCP yearly utility impact.
What plumbing or duct constraints rule out Chicago Faucets 152-ALCP?
Compare where Chicago Faucets 152-ALCP excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Low static water supply pressure <30 PSI
Best-Fit Homeowner Profiles
- Homeowner profile: Claiming utility rebates across 200 U.S. WaterSense programs
- Suited to: Lowering household draw to 4,380 gal/person/yr
What should homeowners verify first about Chicago Faucets 152-ALCP?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Chicago Faucets 152-ALCP.
How does Chicago Faucets 152-ALCP perform relative to the EPA WaterSense category median?
Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.5 gpm, Chicago Faucets 152-ALCP sits below the category median while clearing federal WaterSense caps.
How much does a 3-resident family save yearly switching to Chicago Faucets 152-ALCP?
At $11 per 1,000 gallons, a 3-person household conserving 21,900 gallons/yr with Chicago Faucets 152-ALCP trims roughly $241 annually off water and sewer utility bills.
What anti-scald valve standard pairs with Chicago Faucets 152-ALCP?
Pairing Chicago Faucets 152-ALCP (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.
How is EPA WaterSense performance tested beyond raw gpm flow caps?
EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.
Does installing Chicago Faucets 152-ALCP require a municipal plumbing permit?
Like-for-like swaps using Chicago Faucets 152-ALCP on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
Why upgrade a 4.0 gpm fixture to Chicago Faucets 152-ALCP at 1.5 gpm?
Swapping a 4.0 gpm unit for Chicago Faucets 152-ALCP slashes water draw 62.5% (7,300 gal/person/yr), beating 2.5 gpm federal EPAct standards by 40.0%.
When can Chicago Faucets 152-ALCP (1.5 gpm) underperform in an older bathroom?
Skip Chicago Faucets 152-ALCP without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.
How do 133 WaterSense rebate programs treat Chicago Faucets 152-ALCP?
Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Chicago Faucets 152-ALCP, itemized purchase invoices, and residential installation addresses.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)