Crescent P1 CP WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Crescent (1 SKU)
Verified Specification Summary

Verified by EPA WaterSense at 1.75 gpm, Crescent P1 CP sits 30.0% under federal 2.5 gpm ceilings (#3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads) and saves ~15,330 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for Crescent P1 CP WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.75 gpm
vs. EPAct 1992
-30.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,110 gal/yr
Annual Saved vs. Legacy
5,110 gal/person
Brand EPA Count
19 showerheads
Series / Variants
P1 CP (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Crescent P1 CP Benchmark & Water Budget show?

Under EPA WaterSense protocols, Crescent P1 CP delivers 1.75 gpm (#3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads), beating the 2.5 gpm federal ceiling by 30.0%.

Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Crescent holds 19 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).

Where does Crescent P1 CP rank among 18,544 certified showerheads?

Review how Crescent P1 CP (1.75 gpm) places inside EPA WaterSense's 18,544-SKU showerhead registry alongside historical 3.5 gpm units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): P1 CP: 1.75; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)P1 CP: 1.75P1 CP1.75EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.75 gpm: 1.75 gpm (53rd percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.75 gpm: 1.75 gpm (P53)

What plumbing rough-in clearances prevent leaks around Crescent P1 CP?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which certified attributes define Crescent P1 CP performance?

Official U.S. EPA WaterSense registry entries below confirm Crescent P1 CP rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Crescent (19 certified) EPA WaterSense Partner
Model Number / Series P1 CP Certified Series (1 finish variants)
Rated Consumption 1.75 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How do Crescent P1 CP savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to Crescent P1 CP across different household sizes.

Computed annual water savings for Crescent P1 CP (1.75 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,110 gal2,190 gal5,110 gal (~$56)
2 Occupants10,220 gal4,380 gal10,220 gal (~$112)
3 Occupants15,330 gal6,570 gal15,330 gal (~$123–$276)
4 Occupants20,440 gal8,760 gal20,440 gal (~$225)

Which peer fixtures deliver flow close to Crescent P1 CP?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen+roth 5283486 1.75 gpm (Same flow) WaterSense
Axor 38442xx1 1.75 gpm (Same flow) Uno
COBBE KFSCA12102 1.75 gpm (Same flow) KFSCA12102
Current 01932-T 1.75 gpm (Same flow) WaterSense
DORNBRACHT 28.647.970-xx0010 1.75 gpm (Same flow) WaterSense

Does Crescent P1 CP pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark Crescent P1 CP annual savings immediately.

Where should contractors skip Crescent P1 CP on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Crescent P1 CP carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Choose this if: Upgrading 3.5 gpm fixtures for 50.0% water reduction
  • Works well for: Matching Crescent SKU P1 CP certification on rebate forms

Where do official rules set limits for Crescent P1 CP?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Crescent P1 CP.

How many gallons per person does Crescent P1 CP save annually?

Each resident saves ~6,570 gallons yearly (56.2% drop) replacing a 4.0 gpm fixture with Crescent P1 CP (1.75 gpm), or 2,190 gal/yr versus 2.5 gpm EPAct baselines.

Who should NOT install Crescent P1 CP without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.75 gpm showerhead.

Can homeowners claim utility rebates when installing Crescent P1 CP?

Because Crescent P1 CP holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is Crescent P1 CP leaner than typical WaterSense showerhead models?

Compared with the 1.8 gpm WaterSense showerhead median, Crescent P1 CP's 1.75 gpm rating places it below category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with Crescent P1 CP?

Upgrading a 4.0 gpm legacy fixture to Crescent P1 CP saves ~19,710 gallons yearly for three occupants, about $217/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with Crescent P1 CP?

Pairing Crescent P1 CP (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Crescent P1 CP require a municipal plumbing permit?

Like-for-like swaps using Crescent P1 CP on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)