Current 001MA4-T WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Current (1 SKU)
Verified Specification Summary

Homeowners upgrading older 3.5 gpm plumbing to Current 001MA4-T (1.75 gpm, #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads) cut 50.0% off legacy draw, conserving ~15,330 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Current 001MA4-T WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.75 gpm
vs. EPAct 1992
-30.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,110 gal/yr
Annual Saved vs. Legacy
5,110 gal/person
Brand EPA Count
31 showerheads
Series / Variants
001MA4-T (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Current 001MA4-T Benchmark & Water Budget show?

Laboratory testing places Current 001MA4-T at 1.75 gpm (balanced WaterSense flow tier), saving 30.0% vs. EPAct 1992 (2.5 gpm) while ranking #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads.

Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Current holds 31 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Tucson - Tucson Water (AZ) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).

How do federal gpm limits contrast with Current 001MA4-T tested flow?

Each bar isolates Current 001MA4-T (1.75 gpm) relative to the EPA cap, federal EPAct 1992 standard (2.5 gpm), and pre-1994 draw.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 001MA4-T: 1.75; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)001MA4-T: 1.75001MA4-T1.75EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.75 gpm: 1.75 gpm (53rd percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.75 gpm: 1.75 gpm (P53)

How does wet-zone tile prep interact with Current 001MA4-T rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What plumbing standards accompany Current 001MA4-T installation?

Verify Current 001MA4-T EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Current (31 certified) EPA WaterSense Partner
Model Number / Series 001MA4-T Certified Series (1 finish variants)
Rated Consumption 1.75 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

What household water budget fits Current 001MA4-T?

Annual consumption rows below translate Current 001MA4-T certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for Current 001MA4-T (1.75 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,110 gal2,190 gal5,110 gal (~$56)
2 Occupants10,220 gal4,380 gal10,220 gal (~$112)
3 Occupants15,330 gal6,570 gal15,330 gal (~$123–$276)
4 Occupants20,440 gal8,760 gal20,440 gal (~$225)

Where can buyers find alternatives to Current 001MA4-T?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen+roth 5283486 1.75 gpm (Same flow) WaterSense
Axor 38442xx1 1.75 gpm (Same flow) Uno
COBBE KFSCA12102 1.75 gpm (Same flow) KFSCA12102
DORNBRACHT 28.647.970-xx0010 1.75 gpm (Same flow) WaterSense
DORNBRACHT 28.665.970-xx0010 1.75 gpm (Same flow) WaterSense

What annual bill drop does Current 001MA4-T achieve for your family?

Calculate annual gallons conserved and dollar savings for Current 001MA4-T using your exact occupant count and utility tariff without submitting personal info.

What plumbing or duct constraints rule out Current 001MA4-T?

Compare where Current 001MA4-T excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Homeowner profile: Meeting 2.5 gpm federal & stricter WaterSense caps
  • Suited to: Targeting ~$169/yr utility savings (3-person home)

Which code checks and cost facts matter for Current 001MA4-T?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Current 001MA4-T.

How does Current 001MA4-T perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.75 gpm, Current 001MA4-T sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Current 001MA4-T?

At $11 per 1,000 gallons, a 3-person household conserving 19,710 gallons/yr with Current 001MA4-T trims roughly $217 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Current 001MA4-T?

Pairing Current 001MA4-T (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Current 001MA4-T require a municipal plumbing permit?

Like-for-like swaps using Current 001MA4-T on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 4.0 gpm fixture to Current 001MA4-T at 1.75 gpm?

Swapping a 4.0 gpm unit for Current 001MA4-T slashes water draw 56.2% (6,570 gal/person/yr), beating 2.5 gpm federal EPAct standards by 30.0%.

When can Current 001MA4-T (1.75 gpm) underperform in an older bathroom?

Skip Current 001MA4-T without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Current 001MA4-T?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Current 001MA4-T, itemized purchase invoices, and residential installation addresses.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories