Skip to main content
Grant Estimator

Danze D503033 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Danze (1 SKU)
Verified Specification Summary

Verified by EPA WaterSense at 1.5 gpm, Danze D503033 sits 40.0% under federal 2.5 gpm ceilings (#559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads) and saves ~17,520 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for Danze D503033 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.5 gpm
vs. EPAct 1992
-40.0% (2.5 gpm)
Annual Draw (1 Pers.)
4,380 gal/yr
Annual Saved vs. Legacy
5,840 gal/person
Brand EPA Count
320 showerheads
Series / Variants
D503033 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Danze D503033 Benchmark & Water Budget show?

Under EPA WaterSense protocols, Danze D503033 delivers 1.5 gpm (#559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads (0.25 gpm lower-flow than the 1.75 gpm median)), beating the 2.5 gpm federal ceiling by 40.0%.

Verify >=30 PSI static water pressure and pair this 1.5 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Danze holds 320 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~17,520 gallons/yr—roughly $140/yr in low-tariff towns ($8/1k gal), $193/yr at national averages ($11/1k gal), or $315/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: Acorn Controls CSH-WSC (1.5 gpm) and ACORN CSH-WSA (1.5 gpm).

Where does Danze D503033 rank among 18,544 certified showerheads?

Review how Danze D503033 (1.50 gpm) places inside EPA WaterSense's 18,544-SKU showerhead registry alongside historical 3.5 gpm units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): D503033: 1.50; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)D503033: 1.50D5030331.50EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.5 gpm: 1.5 gpm (18th percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.5 gpm: 1.5 gpm (P18)

What plumbing rough-in clearances prevent leaks around Danze D503033?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which certified attributes define Danze D503033 performance?

Official U.S. EPA WaterSense registry entries below confirm Danze D503033 rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Danze (320 certified) EPA WaterSense Partner
Model Number / Series D503033 Certified Series (1 finish variants)
Rated Consumption 1.5 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How do Danze D503033 savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to Danze D503033 across different household sizes.

Computed annual water savings for Danze D503033 (1.5 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant4,380 gal2,920 gal5,840 gal (~$64)
2 Occupants8,760 gal5,840 gal11,680 gal (~$128)
3 Occupants13,140 gal8,760 gal17,520 gal (~$140–$315)
4 Occupants17,520 gal11,680 gal23,360 gal (~$257)

Which peer fixtures deliver flow close to Danze D503033?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
Acorn Controls CSH-WSC 1.5 gpm (Same flow) WaterSense
ACORN CSH-WSA 1.5 gpm (Same flow) WaterSense
Aquacubic ASH8469 1.5 gpm (Same flow) WaterSense
California Faucet SH-04T.15 1.5 gpm (Same flow) WaterSense
Chi Liu CL-01627-2 1.5 gpm (Same flow) WaterSense

Does Danze D503033 pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark Danze D503033 annual savings immediately.

What plumbing or duct constraints rule out Danze D503033?

Compare where Danze D503033 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Homeowner profile: Upgrading 3.5 gpm fixtures for 57.1% water reduction
  • Suited to: Matching Danze SKU D503033 certification on rebate forms

Where do official rules set limits for Danze D503033?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Danze D503033.

When can Danze D503033 (1.5 gpm) underperform in an older bathroom?

Skip Danze D503033 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Danze D503033?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Danze D503033, itemized purchase invoices, and residential installation addresses.

How does Danze D503033 perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.5 gpm, Danze D503033 sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Danze D503033?

At $11 per 1,000 gallons, a 3-person household conserving 21,900 gallons/yr with Danze D503033 trims roughly $241 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Danze D503033?

Pairing Danze D503033 (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Danze D503033 require a municipal plumbing permit?

Like-for-like swaps using Danze D503033 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 4.0 gpm fixture to Danze D503033 at 1.5 gpm?

Swapping a 4.0 gpm unit for Danze D503033 slashes water draw 62.5% (7,300 gal/person/yr), beating 2.5 gpm federal EPAct standards by 40.0%.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories