Skip to main content
Grant Estimator

DXV™ D35120770 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · DXV Modulus (1 SKU)
Verified Specification Summary

Verified by EPA WaterSense at 1.8 gpm, DXV™ D35120770 sits 28.0% under federal 2.5 gpm ceilings (#9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads) and saves ~14,892 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for DXV™ D35120770 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.8 gpm
vs. EPAct 1992
-28.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,256 gal/yr
Annual Saved vs. Legacy
4,964 gal/person
Brand EPA Count
12 showerheads
Series / Variants
D35120770 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does DXV™ D35120770 Benchmark & Water Budget show?

Under EPA WaterSense protocols, DXV™ D35120770 (DXV Modulus) delivers 1.8 gpm (#9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads (0.05 gpm higher-flow than the 1.75 gpm median)), beating the 2.5 gpm federal ceiling by 28.0%.

Verify >=30 PSI static water pressure and pair this 1.8 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: DXV™ holds 12 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~14,892 gallons/yr—roughly $119/yr in low-tariff towns ($8/1k gal), $164/yr at national averages ($11/1k gal), or $268/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 EBD511TO (1.8 gpm) and Better Homes & Gardens BH27097026121TC (1.8 gpm).

Where does DXV™ D35120770 rank among 18,544 certified showerheads?

Review how DXV™ D35120770 (1.80 gpm) places inside EPA WaterSense's 18,544-SKU showerhead registry alongside historical 3.5 gpm units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): D35120770: 1.80; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)D35120770: 1.80D351207701.80EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.8 gpm: 1.8 gpm (81st percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.8 gpm: 1.8 gpm (P81)

What plumbing rough-in clearances prevent leaks around DXV™ D35120770?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which certified attributes define DXV™ D35120770 performance?

Official U.S. EPA WaterSense registry entries below confirm DXV™ D35120770 rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share DXV™ (12 certified) EPA WaterSense Partner
Model Number / Series D35120770 DXV Modulus (1 finish variants)
Rated Consumption 1.8 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How do DXV™ D35120770 savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to DXV™ D35120770 across different household sizes.

Computed annual water savings for DXV™ D35120770 (1.8 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,256 gal2,044 gal4,964 gal (~$55)
2 Occupants10,512 gal4,088 gal9,928 gal (~$109)
3 Occupants15,768 gal6,132 gal14,892 gal (~$119–$268)
4 Occupants21,024 gal8,176 gal19,856 gal (~$218)

Which peer fixtures deliver flow close to DXV™ D35120770?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 EBD511TO 1.8 gpm (Same flow) Embellish
Better Homes & Gardens BH27097026121TC 1.8 gpm (Same flow) WaterSense
DANCO 12158 1.8 gpm (Same flow) WaterSense
Design House 547430 1.8 gpm (Same flow) Madison
For Living 063-6530-2 1.8 gpm (Same flow) WaterSense

Does DXV™ D35120770 pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark DXV™ D35120770 annual savings immediately.

When does DXV™ D35120770 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering DXV™ D35120770.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Recommended when: Upgrading 3.5 gpm fixtures for 48.6% water reduction
  • Target scenario: Matching DXV™ SKU D35120770 certification on rebate forms

Where do official rules set limits for DXV™ D35120770?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing DXV™ D35120770.

When can DXV™ D35120770 (1.8 gpm) underperform in an older bathroom?

Skip DXV™ D35120770 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat DXV™ D35120770?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like DXV™ D35120770, itemized purchase invoices, and residential installation addresses.

How does DXV™ D35120770 perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.8 gpm, DXV™ D35120770 sits equal to the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to DXV™ D35120770?

At $11 per 1,000 gallons, a 3-person household conserving 19,272 gallons/yr with DXV™ D35120770 trims roughly $212 annually off water and sewer utility bills.

What anti-scald valve standard pairs with DXV™ D35120770?

Pairing DXV™ D35120770 (1.8 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.8 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing DXV™ D35120770 require a municipal plumbing permit?

Like-for-like swaps using DXV™ D35120770 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does DXV™ D35120770 achieve over older plumbing?

Testing at 1.8 gpm, DXV™ D35120770 uses 55.0% less water than 4.0 gpm pre-1994 models (28.0% below 2.5 gpm EPAct), conserving 6,424 gallons per resident each year.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories