Skip to main content
Grant Estimator

Evolve EV3382-CP125-CT-TR WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Evolve (1 SKU)
Verified Specification Summary

Verified by EPA WaterSense at 1.25 gpm, Evolve EV3382-CP125-CT-TR sits 50.0% under federal 2.5 gpm ceilings (#56 of 18,544 certified showerheads; most water-efficient 3.0% of 18,544 certified showerheads, lower-flow than 97.0% of certified showerheads) and saves ~19,710 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for Evolve EV3382-CP125-CT-TR WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.25 gpm
vs. EPAct 1992
-50.0% (2.5 gpm)
Annual Draw (1 Pers.)
3,650 gal/yr
Annual Saved vs. Legacy
6,570 gal/person
Brand EPA Count
93 showerheads
Series / Variants
EV3382-CP125-CT-TR (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Evolve EV3382-CP125-CT-TR Benchmark & Water Budget show?

Under EPA WaterSense protocols, Evolve EV3382-CP125-CT-TR delivers 1.25 gpm (#56 of 18,544 certified showerheads; most water-efficient 3.0% of 18,544 certified showerheads, lower-flow than 97.0% of certified showerheads (0.50 gpm lower-flow than the 1.75 gpm median)), beating the 2.5 gpm federal ceiling by 50.0%.

Verify >=30 PSI static water pressure and pair this 1.25 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Evolve holds 93 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~19,710 gallons/yr—roughly $158/yr in low-tariff towns ($8/1k gal), $217/yr at national averages ($11/1k gal), or $355/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: ECO-LOGICAL B125-CH (1.25 gpm) and ECO-LOGICAL B125-W (1.25 gpm).

Where does Evolve EV3382-CP125-CT-TR rank among 18,544 certified showerheads?

Review how Evolve EV3382-CP125-CT-TR (1.25 gpm) places inside EPA WaterSense's 18,544-SKU showerhead registry alongside historical 3.5 gpm units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): EV3382-CP125-CT-TR: 1.25; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)EV3382-CP125-CT-TR: 1.25EV3382-CP125-CT-TR1.25EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.25 gpm: 1.25 gpm (3rd percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.25 gpm: 1.25 gpm (P3)

What plumbing rough-in clearances prevent leaks around Evolve EV3382-CP125-CT-TR?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which certified attributes define Evolve EV3382-CP125-CT-TR performance?

Official U.S. EPA WaterSense registry entries below confirm Evolve EV3382-CP125-CT-TR rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Evolve (93 certified) EPA WaterSense Partner
Model Number / Series EV3382-CP125-CT-TR Certified Series (1 finish variants)
Rated Consumption 1.25 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How do Evolve EV3382-CP125-CT-TR savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to Evolve EV3382-CP125-CT-TR across different household sizes.

Computed annual water savings for Evolve EV3382-CP125-CT-TR (1.25 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant3,650 gal3,650 gal6,570 gal (~$72)
2 Occupants7,300 gal7,300 gal13,140 gal (~$145)
3 Occupants10,950 gal10,950 gal19,710 gal (~$158–$355)
4 Occupants14,600 gal14,600 gal26,280 gal (~$289)

Which peer fixtures deliver flow close to Evolve EV3382-CP125-CT-TR?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
ECO-LOGICAL B125-CH 1.25 gpm (Same flow) Showerhead
ECO-LOGICAL B125-W 1.25 gpm (Same flow) Showerhead
EVOLVE/AM EV3019-BN125-FB 1.25 gpm (Same flow) Showerhead
EVOLVE/AM EV3019-CP125-FB 1.25 gpm (Same flow) Showerhead
EVOLVE/AM EV3019-MB125-FB 1.25 gpm (Same flow) Showerhead

Does Evolve EV3382-CP125-CT-TR pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark Evolve EV3382-CP125-CT-TR annual savings immediately.

Does Evolve EV3382-CP125-CT-TR suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Evolve EV3382-CP125-CT-TR for your remodel.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Strong scenario: Upgrading 3.5 gpm fixtures for 64.3% water reduction
  • Best application: Matching Evolve SKU EV3382-CP125-CT-TR certification on rebate forms

Where do official rules set limits for Evolve EV3382-CP125-CT-TR?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Evolve EV3382-CP125-CT-TR.

Does Evolve EV3382-CP125-CT-TR qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Evolve EV3382-CP125-CT-TR eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does Evolve EV3382-CP125-CT-TR rank against other certified showerheads?

Rated at 1.25 gpm, Evolve EV3382-CP125-CT-TR measures below the 1.8 gpm WaterSense showerhead median across thousands of EPA-listed residential fixtures.

Does Evolve EV3382-CP125-CT-TR cut utility costs noticeably for a 3-person household?

Yes: cutting 24,090 gallons/yr relative to 4.0 gpm hardware translates to ~$265/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with Evolve EV3382-CP125-CT-TR?

Pairing Evolve EV3382-CP125-CT-TR (1.25 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.25 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Evolve EV3382-CP125-CT-TR require a municipal plumbing permit?

Like-for-like swaps using Evolve EV3382-CP125-CT-TR on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What efficiency edge separates Evolve EV3382-CP125-CT-TR from legacy and EPAct models?

Certified at 1.25 gpm, Evolve EV3382-CP125-CT-TR achieves 50.0% savings against EPAct 1992 (2.5 gpm) and 68.8% savings against 4.0 gpm fixtures, 8,030 gallons per occupant yearly.

What supply pressure checks protect Evolve EV3382-CP125-CT-TR spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.25 gpm trim.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories