Evolve EV3382-CP150-CT WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Evolve (2 SKUs)
Verified Specification Summary

Certified under EPA WaterSense, Evolve EV3382-CP150-CT tests at 1.5 gpm (#559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads), trimming 40.0% off the 2.5 gpm federal cap while cutting 3-person household draw by ~17,520 gal/yr versus 3.5 gpm fixtures. Compare EPA WaterSense certified flow metrics for Evolve EV3382-CP150-CT WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.5 gpm
vs. EPAct 1992
-40.0% (2.5 gpm)
Annual Draw (1 Pers.)
4,380 gal/yr
Annual Saved vs. Legacy
5,840 gal/person
Brand EPA Count
93 showerheads
Series / Variants
EV3382-CP150-CT (2)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Evolve EV3382-CP150-CT Benchmark & Water Budget show?

Efficiency check: certified at 1.5 gpm, Evolve EV3382-CP150-CT trims 40.0% under federal 2.5 gpm caps; #559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads (0.25 gpm lower-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.5 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Evolve holds 93 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~17,520 gallons/yr—roughly $140/yr in low-tariff towns ($8/1k gal), $193/yr at national averages ($11/1k gal), or $315/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: Acorn Controls CSH-WSC (1.5 gpm) and ACORN CSH-WSA (1.5 gpm).

Where does Evolve EV3382-CP150-CT sit on the EPA WaterSense showerhead flow curve?

Comparing Evolve EV3382-CP150-CT (1.50 gpm) against federal EPAct (2.5 gpm) and legacy (3.5 gpm) baselines shows immediate per-use conservation.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): EV3382-CP150-CT: 1.50; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)EV3382-CP150-CT: 1.50EV3382-CP150-CT1.50EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.5 gpm: 1.5 gpm (18th percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.5 gpm: 1.5 gpm (P18)

How do subfloor levelness and rough-in height protect Evolve EV3382-CP150-CT?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What official WaterSense figures verify Evolve EV3382-CP150-CT?

Examine Evolve EV3382-CP150-CT certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Evolve (93 certified) EPA WaterSense Partner
Model Number / Series EV3382-CP150-CT Certified Series (2 finish variants)
Rated Consumption 1.5 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 2 finish and trim SKUs share the Evolve EV3382-CP150-CT WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 2 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Evolve EV3382-CP150-CT (2 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
EV3382-CP150-CT1.5 gpmShared Series Spec
EV3382-CP150-CT-TR1.5 gpmShared Series Spec

What annual utility savings does Evolve EV3382-CP150-CT deliver?

Compare 1-to-4-person household water use with Evolve EV3382-CP150-CT against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for Evolve EV3382-CP150-CT (1.5 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant4,380 gal2,920 gal5,840 gal (~$64)
2 Occupants8,760 gal5,840 gal11,680 gal (~$128)
3 Occupants13,140 gal8,760 gal17,520 gal (~$140–$315)
4 Occupants17,520 gal11,680 gal23,360 gal (~$257)

What alternative WaterSense models compare to Evolve EV3382-CP150-CT?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
Acorn Controls CSH-WSC 1.5 gpm (Same flow) WaterSense
ACORN CSH-WSA 1.5 gpm (Same flow) WaterSense
Aquacubic ASH8469 1.5 gpm (Same flow) WaterSense
California Faucet SH-04T.15 1.5 gpm (Same flow) WaterSense
Chi Liu CL-01627-2 1.5 gpm (Same flow) WaterSense

What will Evolve EV3382-CP150-CT save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

When does Evolve EV3382-CP150-CT fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Evolve EV3382-CP150-CT.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Recommended when: Meeting 2.5 gpm federal & stricter WaterSense caps
  • Target scenario: Targeting ~$193/yr utility savings (3-person home)

Which homeowner questions come up most for Evolve EV3382-CP150-CT?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Evolve EV3382-CP150-CT.

How much does a 3-resident family save yearly switching to Evolve EV3382-CP150-CT?

At $11 per 1,000 gallons, a 3-person household conserving 21,900 gallons/yr with Evolve EV3382-CP150-CT trims roughly $241 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Evolve EV3382-CP150-CT?

Pairing Evolve EV3382-CP150-CT (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Evolve EV3382-CP150-CT require a municipal plumbing permit?

Like-for-like swaps using Evolve EV3382-CP150-CT on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does Evolve EV3382-CP150-CT achieve over older plumbing?

Testing at 1.5 gpm, Evolve EV3382-CP150-CT uses 62.5% less water than 4.0 gpm pre-1994 models (40.0% below 2.5 gpm EPAct), conserving 7,300 gallons per resident each year.

When can Evolve EV3382-CP150-CT (1.5 gpm) underperform in an older bathroom?

Skip Evolve EV3382-CP150-CT without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Evolve EV3382-CP150-CT?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Evolve EV3382-CP150-CT, itemized purchase invoices, and residential installation addresses.

How does Evolve EV3382-CP150-CT perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.5 gpm, Evolve EV3382-CP150-CT sits below the category median while clearing federal WaterSense caps.