Skip to main content
Grant Estimator

Fantini 38023380SBU WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Fantini (1 SKU)
Verified Specification Summary

Verified by EPA WaterSense at 1.8 gpm, Fantini 38023380SBU sits 28.0% under federal 2.5 gpm ceilings (#9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads) and saves ~14,892 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for Fantini 38023380SBU WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.8 gpm
vs. EPAct 1992
-28.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,256 gal/yr
Annual Saved vs. Legacy
4,964 gal/person
Brand EPA Count
23 showerheads
Series / Variants
38023380SBU (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Fantini 38023380SBU Benchmark & Water Budget show?

Under EPA WaterSense protocols, Fantini 38023380SBU delivers 1.8 gpm (#9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads (0.05 gpm higher-flow than the 1.75 gpm median)), beating the 2.5 gpm federal ceiling by 28.0%.

Verify >=30 PSI static water pressure and pair this 1.8 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Fantini holds 23 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~14,892 gallons/yr—roughly $119/yr in low-tariff towns ($8/1k gal), $164/yr at national averages ($11/1k gal), or $268/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 EBD511TO (1.8 gpm) and Better Homes & Gardens BH27097026121TC (1.8 gpm).

Where does Fantini 38023380SBU rank among 18,544 certified showerheads?

Review how Fantini 38023380SBU (1.80 gpm) places inside EPA WaterSense's 18,544-SKU showerhead registry alongside historical 3.5 gpm units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 38023380SBU: 1.80; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)38023380SBU: 1.8038023380SBU1.80EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.8 gpm: 1.8 gpm (81st percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.8 gpm: 1.8 gpm (P81)

What plumbing rough-in clearances prevent leaks around Fantini 38023380SBU?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified attributes define Fantini 38023380SBU performance?

Official U.S. EPA WaterSense registry entries below confirm Fantini 38023380SBU rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Fantini (23 certified) EPA WaterSense Partner
Model Number / Series 38023380SBU Certified Series (1 finish variants)
Rated Consumption 1.8 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How do Fantini 38023380SBU savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to Fantini 38023380SBU across different household sizes.

Computed annual water savings for Fantini 38023380SBU (1.8 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,256 gal2,044 gal4,964 gal (~$55)
2 Occupants10,512 gal4,088 gal9,928 gal (~$109)
3 Occupants15,768 gal6,132 gal14,892 gal (~$119–$268)
4 Occupants21,024 gal8,176 gal19,856 gal (~$218)

Which peer fixtures deliver flow close to Fantini 38023380SBU?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 EBD511TO 1.8 gpm (Same flow) Embellish
Better Homes & Gardens BH27097026121TC 1.8 gpm (Same flow) WaterSense
DANCO 12158 1.8 gpm (Same flow) WaterSense
Design House 547430 1.8 gpm (Same flow) Madison
For Living 063-6530-2 1.8 gpm (Same flow) WaterSense

Does Fantini 38023380SBU pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark Fantini 38023380SBU annual savings immediately.

Which bath layouts should avoid specifying Fantini 38023380SBU?

Match Fantini 38023380SBU directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Best for: Upgrading 3.5 gpm fixtures for 48.6% water reduction
  • Optimal use: Matching Fantini SKU 38023380SBU certification on rebate forms

Where do official rules set limits for Fantini 38023380SBU?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Fantini 38023380SBU.

Does Fantini 38023380SBU qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Fantini 38023380SBU eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does Fantini 38023380SBU rank against other certified showerheads?

Rated at 1.8 gpm, Fantini 38023380SBU measures equal to the 1.8 gpm WaterSense showerhead median across thousands of EPA-listed residential fixtures.

Does Fantini 38023380SBU cut utility costs noticeably for a 3-person household?

Yes: cutting 19,272 gallons/yr relative to 4.0 gpm hardware translates to ~$212/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with Fantini 38023380SBU?

Pairing Fantini 38023380SBU (1.8 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.8 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Fantini 38023380SBU require a municipal plumbing permit?

Like-for-like swaps using Fantini 38023380SBU on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How does Fantini 38023380SBU cut household water draw versus 1992 federal rules?

Delivering 1.8 gpm, Fantini 38023380SBU trims 2,044 gal/person/yr below 2.5 gpm EPAct caps (28.0% reduction) and 6,424 gal/person/yr under 4.0 gpm legacy fixtures.

What supply pressure checks protect Fantini 38023380SBU spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.8 gpm trim.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories