Skip to main content
Grant Estimator

Franz Viegener FV126.07/87 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Temple Plus showerhead (1 SKU)
Verified Specification Summary

Operating at 1.6 gpm, the Franz Viegener FV126.07/87 showerhead beats 1992 EPAct rules (2.5 gpm) by 36.0% (#3,348 of 18,544 certified showerheads; most water-efficient 18.3% of 18,544 certified showerheads, lower-flow than 81.7% of certified showerheads), saving a 3-resident home ~16,644 gallons annually compared to 3.5 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for Franz Viegener FV126.07/87 WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.6 gpm
vs. EPAct 1992
-36.0% (2.5 gpm)
Annual Draw (1 Pers.)
4,672 gal/yr
Annual Saved vs. Legacy
5,548 gal/person
Brand EPA Count
65 showerheads
Series / Variants
FV126.07/87 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Franz Viegener FV126.07/87 Benchmark & Water Budget show?

WaterSense benchmark: Franz Viegener series FV126.07/87 (Temple Plus showerhead) verifies 1.6 gpm delivery, scoring 36.0% leaner than EPAct 1992 (2.5 gpm) at #3,348 of 18,544 certified showerheads; most water-efficient 18.3% of 18,544 certified showerheads, lower-flow than 81.7% of certified showerheads (0.15 gpm lower-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.6 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Franz Viegener holds 65 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~16,644 gallons/yr—roughly $133/yr in low-tariff towns ($8/1k gal), $183/yr at national averages ($11/1k gal), or $300/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: Alsons 655 (1.6 gpm) and Aquacubic ASH7328 (1.6 gpm).

How much leaner is Franz Viegener FV126.07/87 than pre-1994 3.5 gpm plumbing?

Flow distribution bars contrast Franz Viegener FV126.07/87 (1.60 gpm) directly with the 1.75 gpm WaterSense median and 3.5 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): FV126.07/87: 1.60; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)FV126.07/87: 1.60FV126.07/871.60EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.6 gpm: 1.6 gpm (18th percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.6 gpm: 1.6 gpm (P18)

Which framing and flange tolerances matter before installing Franz Viegener FV126.07/87?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does Franz Viegener FV126.07/87 compare to WaterSense category caps?

Each specification row below documents Franz Viegener FV126.07/87 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Franz Viegener (65 certified) EPA WaterSense Partner
Model Number / Series FV126.07/87 Temple Plus showerhead (1 finish variants)
Rated Consumption 1.6 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does Franz Viegener FV126.07/87 cut?

Calculated annual water budgets below quantify Franz Viegener FV126.07/87 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for Franz Viegener FV126.07/87 (1.6 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant4,672 gal2,628 gal5,548 gal (~$61)
2 Occupants9,344 gal5,256 gal11,096 gal (~$122)
3 Occupants14,016 gal7,884 gal16,644 gal (~$133–$300)
4 Occupants18,688 gal10,512 gal22,192 gal (~$244)

Which competing models share Franz Viegener FV126.07/87 flow tier?

Review five peer WaterSense units matching Franz Viegener FV126.07/87 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
Alsons 655 1.6 gpm (Same flow) WaterSense
Aquacubic ASH7328 1.6 gpm (Same flow) WaterSense
Bricor B110 CH-HH 1.6 gpm (Same flow) Handheld B110
Cantrio 701.703 1.6 gpm (Same flow) 8" Rain Showerhead with arm
Cantrio 815.551 1.6 gpm (Same flow) Personal Hand Shower with Holder and...

Can you estimate Franz Viegener FV126.07/87 payback in your home?

Test how many gallons and dollars Franz Viegener FV126.07/87 saves each year by entering your household residents and local water-sewer rate below.

Which bath layouts should avoid specifying Franz Viegener FV126.07/87?

Match Franz Viegener FV126.07/87 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Best for: Upgrading 3.5 gpm fixtures for 54.3% water reduction
  • Optimal use: Matching Franz Viegener SKU FV126.07/87 certification on rebate forms

How do federal and code standards apply to Franz Viegener FV126.07/87?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Franz Viegener FV126.07/87.

What supply pressure checks protect Franz Viegener FV126.07/87 spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.6 gpm trim.

Does Franz Viegener FV126.07/87 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Franz Viegener FV126.07/87 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does Franz Viegener FV126.07/87 rank against other certified showerheads?

Rated at 1.6 gpm, Franz Viegener FV126.07/87 measures below the 1.8 gpm WaterSense showerhead median across thousands of EPA-listed residential fixtures.

Does Franz Viegener FV126.07/87 cut utility costs noticeably for a 3-person household?

Yes: cutting 21,024 gallons/yr relative to 4.0 gpm hardware translates to ~$231/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with Franz Viegener FV126.07/87?

Pairing Franz Viegener FV126.07/87 (1.6 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.6 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Franz Viegener FV126.07/87 require a municipal plumbing permit?

Like-for-like swaps using Franz Viegener FV126.07/87 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How does Franz Viegener FV126.07/87 cut household water draw versus 1992 federal rules?

Delivering 1.6 gpm, Franz Viegener FV126.07/87 trims 2,628 gal/person/yr below 2.5 gpm EPAct caps (36.0% reduction) and 7,008 gal/person/yr under 4.0 gpm legacy fixtures.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories