Skip to main content
Grant Estimator

Franz Viegener FV133/J9.0 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Franz Viegener (27 SKUs)
Verified Specification Summary

Homeowners upgrading older 3.5 gpm plumbing to Franz Viegener FV133/J9.0 (1.75 gpm, #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads) cut 50.0% off legacy draw, conserving ~15,330 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Franz Viegener FV133/J9.0 WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.75 gpm
vs. EPAct 1992
-30.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,110 gal/yr
Annual Saved vs. Legacy
5,110 gal/person
Brand EPA Count
65 showerheads
Series / Variants
FV133/J9.0 (27)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Franz Viegener FV133/J9.0 Benchmark & Water Budget show?

Laboratory testing places Franz Viegener FV133/J9.0 at 1.75 gpm (balanced WaterSense flow tier), saving 30.0% vs. EPAct 1992 (2.5 gpm) while ranking #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads.

Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Franz Viegener holds 65 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Tucson - Tucson Water (AZ) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).

How do federal gpm limits contrast with Franz Viegener FV133/J9.0 tested flow?

Each bar isolates Franz Viegener FV133/J9.0 (1.75 gpm) relative to the EPA cap, federal EPAct 1992 standard (2.5 gpm), and pre-1994 draw.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): FV133/J9.0: 1.75; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)FV133/J9.0: 1.75FV133/J9.01.75EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.75 gpm: 1.75 gpm (53rd percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.75 gpm: 1.75 gpm (P53)

How does wet-zone tile prep interact with Franz Viegener FV133/J9.0 rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What plumbing standards accompany Franz Viegener FV133/J9.0 installation?

Verify Franz Viegener FV133/J9.0 EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Franz Viegener (65 certified) EPA WaterSense Partner
Model Number / Series FV133/J9.0 Certified Series (27 finish variants)
Rated Consumption 1.75 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 27 finish and trim SKUs share the Franz Viegener FV133/J9.0 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 8 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Franz Viegener FV133/J9.0 (27 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
FV133/J9.01.75 gpmShared Series Spec
FV133/60.01.75 gpmShared Series Spec
FV133/J3.01.75 gpmShared Series Spec
FV133/J3D.01.75 gpmShared Series Spec
FV133/J4.01.75 gpmShared Series Spec
FV133/J1.01.75 gpmShared Series Spec
FV133/K2.01.75 gpmShared Series Spec
FV133/85L.01.75 gpmShared Series Spec

What household water budget fits Franz Viegener FV133/J9.0?

Annual consumption rows below translate Franz Viegener FV133/J9.0 certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for Franz Viegener FV133/J9.0 (1.75 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,110 gal2,190 gal5,110 gal (~$56)
2 Occupants10,220 gal4,380 gal10,220 gal (~$112)
3 Occupants15,330 gal6,570 gal15,330 gal (~$123–$276)
4 Occupants20,440 gal8,760 gal20,440 gal (~$225)

Where can buyers find alternatives to Franz Viegener FV133/J9.0?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen+roth 5283486 1.75 gpm (Same flow) WaterSense
Axor 38442xx1 1.75 gpm (Same flow) Uno
COBBE KFSCA12102 1.75 gpm (Same flow) KFSCA12102
Current 01932-T 1.75 gpm (Same flow) WaterSense
DORNBRACHT 28.647.970-xx0010 1.75 gpm (Same flow) WaterSense

What annual bill drop does Franz Viegener FV133/J9.0 achieve for your family?

Calculate annual gallons conserved and dollar savings for Franz Viegener FV133/J9.0 using your exact occupant count and utility tariff without submitting personal info.

Who should not install Franz Viegener FV133/J9.0 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Franz Viegener FV133/J9.0 for residential use.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Ideal fit: Meeting 2.5 gpm federal & stricter WaterSense caps
  • Primary match: Targeting ~$169/yr utility savings (3-person home)

Which code checks and cost facts matter for Franz Viegener FV133/J9.0?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Franz Viegener FV133/J9.0.

What annual dollar savings can a 3-person home expect with Franz Viegener FV133/J9.0?

Upgrading a 4.0 gpm legacy fixture to Franz Viegener FV133/J9.0 saves ~19,710 gallons yearly for three occupants, about $217/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with Franz Viegener FV133/J9.0?

Pairing Franz Viegener FV133/J9.0 (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Franz Viegener FV133/J9.0 require a municipal plumbing permit?

Like-for-like swaps using Franz Viegener FV133/J9.0 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How much water does Franz Viegener FV133/J9.0 save compared with EPAct 1992 and pre-1994 fixtures?

Rated at 1.75 gpm, Franz Viegener FV133/J9.0 cuts 30.0% below the 2.5 gpm EPAct 1992 ceiling and 56.2% under 4.0 gpm legacy units, saving 6,570 gal/person/yr (2,190 vs EPAct).

Who should NOT install Franz Viegener FV133/J9.0 without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.75 gpm showerhead.

Can homeowners claim utility rebates when installing Franz Viegener FV133/J9.0?

Because Franz Viegener FV133/J9.0 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is Franz Viegener FV133/J9.0 leaner than typical WaterSense showerhead models?

Compared with the 1.8 gpm WaterSense showerhead median, Franz Viegener FV133/J9.0's 1.75 gpm rating places it below category norms inside EPA conservation limits.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories