FREENDO 192-6176 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · FREENDO (1 SKU)
Verified Specification Summary

Operating at 1.5 gpm, the FREENDO 192-6176 showerhead beats 1992 EPAct rules (2.5 gpm) by 40.0% (#559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads), saving a 3-resident home ~17,520 gallons annually compared to 3.5 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for FREENDO 192-6176 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.5 gpm
vs. EPAct 1992
-40.0% (2.5 gpm)
Annual Draw (1 Pers.)
4,380 gal/yr
Annual Saved vs. Legacy
5,840 gal/person
Brand EPA Count
148 showerheads
Series / Variants
192-6176 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does FREENDO 192-6176 Benchmark & Water Budget show?

WaterSense benchmark: FREENDO series 192-6176 verifies 1.5 gpm delivery, scoring 40.0% leaner than EPAct 1992 (2.5 gpm) at #559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads (0.25 gpm lower-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.5 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: FREENDO holds 148 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~17,520 gallons/yr—roughly $140/yr in low-tariff towns ($8/1k gal), $193/yr at national averages ($11/1k gal), or $315/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Tucson - Tucson Water (AZ) list active rebates among 200 U.S. programs. Closest alternatives: Acorn Controls CSH-WSC (1.5 gpm) and ACORN CSH-WSA (1.5 gpm).

How much leaner is FREENDO 192-6176 than pre-1994 3.5 gpm plumbing?

Flow distribution bars contrast FREENDO 192-6176 (1.50 gpm) directly with the 1.75 gpm WaterSense median and 3.5 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 192-6176: 1.50; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)192-6176: 1.50192-61761.50EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.5 gpm: 1.5 gpm (18th percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.5 gpm: 1.5 gpm (P18)

Which framing and flange tolerances matter before installing FREENDO 192-6176?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does FREENDO 192-6176 compare to WaterSense category caps?

Each specification row below documents FREENDO 192-6176 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share FREENDO (148 certified) EPA WaterSense Partner
Model Number / Series 192-6176 Certified Series (1 finish variants)
Rated Consumption 1.5 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does FREENDO 192-6176 cut?

Calculated annual water budgets below quantify FREENDO 192-6176 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for FREENDO 192-6176 (1.5 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant4,380 gal2,920 gal5,840 gal (~$64)
2 Occupants8,760 gal5,840 gal11,680 gal (~$128)
3 Occupants13,140 gal8,760 gal17,520 gal (~$140–$315)
4 Occupants17,520 gal11,680 gal23,360 gal (~$257)

Which competing models share FREENDO 192-6176 flow tier?

Review five peer WaterSense units matching FREENDO 192-6176 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
Acorn Controls CSH-WSC 1.5 gpm (Same flow) WaterSense
ACORN CSH-WSA 1.5 gpm (Same flow) WaterSense
Aquacubic ASH8469 1.5 gpm (Same flow) WaterSense
California Faucet SH-04T.15 1.5 gpm (Same flow) WaterSense
Chi Liu CL-01627-2 1.5 gpm (Same flow) WaterSense

Can you estimate FREENDO 192-6176 payback in your home?

Test how many gallons and dollars FREENDO 192-6176 saves each year by entering your household residents and local water-sewer rate below.

What plumbing or duct constraints rule out FREENDO 192-6176?

Compare where FREENDO 192-6176 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Homeowner profile: Upgrading 3.5 gpm fixtures for 57.1% water reduction
  • Suited to: Matching FREENDO SKU 192-6176 certification on rebate forms

How do federal and code standards apply to FREENDO 192-6176?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for FREENDO 192-6176.

How do 133 WaterSense rebate programs treat FREENDO 192-6176?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like FREENDO 192-6176, itemized purchase invoices, and residential installation addresses.

How does FREENDO 192-6176 perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.5 gpm, FREENDO 192-6176 sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to FREENDO 192-6176?

At $11 per 1,000 gallons, a 3-person household conserving 21,900 gallons/yr with FREENDO 192-6176 trims roughly $241 annually off water and sewer utility bills.

What anti-scald valve standard pairs with FREENDO 192-6176?

Pairing FREENDO 192-6176 (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing FREENDO 192-6176 require a municipal plumbing permit?

Like-for-like swaps using FREENDO 192-6176 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 4.0 gpm fixture to FREENDO 192-6176 at 1.5 gpm?

Swapping a 4.0 gpm unit for FREENDO 192-6176 slashes water draw 62.5% (7,300 gal/person/yr), beating 2.5 gpm federal EPAct standards by 40.0%.

When can FREENDO 192-6176 (1.5 gpm) underperform in an older bathroom?

Skip FREENDO 192-6176 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)