Skip to main content
Grant Estimator

HELVEX UH-3008-WOA WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · HELVEX (3 SKUs)
Verified Specification Summary

Certified under EPA WaterSense, HELVEX UH-3008-WOA tests at 1.7 gpm (#3,387 of 18,544 certified showerheads; most water-efficient 18.5% of 18,544 certified showerheads, lower-flow than 81.5% of certified showerheads), trimming 32.0% off the 2.5 gpm federal cap while cutting 3-person household draw by ~15,768 gal/yr versus 3.5 gpm fixtures. Compare EPA WaterSense certified flow metrics for HELVEX UH-3008-WOA WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.7 gpm
vs. EPAct 1992
-32.0% (2.5 gpm)
Annual Draw (1 Pers.)
4,964 gal/yr
Annual Saved vs. Legacy
5,256 gal/person
Brand EPA Count
32 showerheads
Series / Variants
UH-3008-WOA (3)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does HELVEX UH-3008-WOA Benchmark & Water Budget show?

Efficiency check: certified at 1.7 gpm, HELVEX UH-3008-WOA trims 32.0% under federal 2.5 gpm caps; #3,387 of 18,544 certified showerheads; most water-efficient 18.5% of 18,544 certified showerheads, lower-flow than 81.5% of certified showerheads (0.05 gpm lower-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.7 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: HELVEX holds 32 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,768 gallons/yr—roughly $126/yr in low-tariff towns ($8/1k gal), $173/yr at national averages ($11/1k gal), or $284/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: Crescent X1 CP (1.7 gpm) and Crescent X3 CP (1.7 gpm).

Where does HELVEX UH-3008-WOA sit on the EPA WaterSense showerhead flow curve?

Comparing HELVEX UH-3008-WOA (1.70 gpm) against federal EPAct (2.5 gpm) and legacy (3.5 gpm) baselines shows immediate per-use conservation.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): UH-3008-WOA: 1.70; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)UH-3008-WOA: 1.70UH-3008-WOA1.70EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.7 gpm: 1.7 gpm (18th percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.7 gpm: 1.7 gpm (P18)

How do subfloor levelness and rough-in height protect HELVEX UH-3008-WOA?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What official WaterSense figures verify HELVEX UH-3008-WOA?

Examine HELVEX UH-3008-WOA certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share HELVEX (32 certified) EPA WaterSense Partner
Model Number / Series UH-3008-WOA Certified Series (3 finish variants)
Rated Consumption 1.7 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 3 finish and trim SKUs share the HELVEX UH-3008-WOA WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 3 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into HELVEX UH-3008-WOA (3 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
UH-3008-WOA***1.7 gpmShared Series Spec
UH-3008-TR-037***1.7 gpmShared Series Spec
UH-3008-TR-035***1.7 gpmShared Series Spec

What annual utility savings does HELVEX UH-3008-WOA deliver?

Compare 1-to-4-person household water use with HELVEX UH-3008-WOA against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for HELVEX UH-3008-WOA (1.7 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant4,964 gal2,336 gal5,256 gal (~$58)
2 Occupants9,928 gal4,672 gal10,512 gal (~$116)
3 Occupants14,892 gal7,008 gal15,768 gal (~$126–$284)
4 Occupants19,856 gal9,344 gal21,024 gal (~$231)

What alternative WaterSense models compare to HELVEX UH-3008-WOA?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
Crescent X1 CP 1.7 gpm (Same flow) WaterSense
Crescent X3 CP 1.7 gpm (Same flow) WaterSense
Jaclo Industries B200 1.7 gpm (Same flow) WaterSense
Jaclo Industries B240 1.7 gpm (Same flow) WaterSense
Jaclo Industries B718 1.7 gpm (Same flow) WaterSense

What will HELVEX UH-3008-WOA save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

Does HELVEX UH-3008-WOA suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying HELVEX UH-3008-WOA for your remodel.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Strong scenario: Meeting 2.5 gpm federal & stricter WaterSense caps
  • Best application: Targeting ~$173/yr utility savings (3-person home)

Which homeowner questions come up most for HELVEX UH-3008-WOA?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around HELVEX UH-3008-WOA.

Does HELVEX UH-3008-WOA cut utility costs noticeably for a 3-person household?

Yes: cutting 20,148 gallons/yr relative to 4.0 gpm hardware translates to ~$222/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with HELVEX UH-3008-WOA?

Pairing HELVEX UH-3008-WOA (1.7 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.7 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing HELVEX UH-3008-WOA require a municipal plumbing permit?

Like-for-like swaps using HELVEX UH-3008-WOA on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What efficiency edge separates HELVEX UH-3008-WOA from legacy and EPAct models?

Certified at 1.7 gpm, HELVEX UH-3008-WOA achieves 32.0% savings against EPAct 1992 (2.5 gpm) and 57.5% savings against 4.0 gpm fixtures, 6,716 gallons per occupant yearly.

What supply pressure checks protect HELVEX UH-3008-WOA spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.7 gpm trim.

Does HELVEX UH-3008-WOA qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes HELVEX UH-3008-WOA eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does HELVEX UH-3008-WOA rank against other certified showerheads?

Rated at 1.7 gpm, HELVEX UH-3008-WOA measures below the 1.8 gpm WaterSense showerhead median across thousands of EPA-listed residential fixtures.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories