Skip to main content
Grant Estimator

Homewerks 3073-501-WS WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Homewerks (2 SKUs)
Verified Specification Summary

Operating at 1.8 gpm, the Homewerks 3073-501-WS showerhead beats 1992 EPAct rules (2.5 gpm) by 28.0% (#9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads), saving a 3-resident home ~14,892 gallons annually compared to 3.5 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for Homewerks 3073-501-WS WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.8 gpm
vs. EPAct 1992
-28.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,256 gal/yr
Annual Saved vs. Legacy
4,964 gal/person
Brand EPA Count
127 showerheads
Series / Variants
3073-501-WS (2)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Homewerks 3073-501-WS Benchmark & Water Budget show?

WaterSense benchmark: Homewerks series 3073-501-WS verifies 1.8 gpm delivery, scoring 28.0% leaner than EPAct 1992 (2.5 gpm) at #9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads (0.05 gpm higher-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.8 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Homewerks holds 127 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~14,892 gallons/yr—roughly $119/yr in low-tariff towns ($8/1k gal), $164/yr at national averages ($11/1k gal), or $268/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 EBD511TO (1.8 gpm) and Better Homes & Gardens BH27097026121TC (1.8 gpm).

How much leaner is Homewerks 3073-501-WS than pre-1994 3.5 gpm plumbing?

Flow distribution bars contrast Homewerks 3073-501-WS (1.80 gpm) directly with the 1.75 gpm WaterSense median and 3.5 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 3073-501-WS: 1.80; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)3073-501-WS: 1.803073-501-WS1.80EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.8 gpm: 1.8 gpm (81st percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.8 gpm: 1.8 gpm (P81)

Which framing and flange tolerances matter before installing Homewerks 3073-501-WS?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does Homewerks 3073-501-WS compare to WaterSense category caps?

Each specification row below documents Homewerks 3073-501-WS tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Homewerks (127 certified) EPA WaterSense Partner
Model Number / Series 3073-501-WS Certified Series (2 finish variants)
Rated Consumption 1.8 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 2 finish and trim SKUs share the Homewerks 3073-501-WS WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 2 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Homewerks 3073-501-WS (2 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
3073-501-WS1.8 gpmShared Series Spec
3073-501-WS11.8 gpmShared Series Spec

How many gallons per year does Homewerks 3073-501-WS cut?

Calculated annual water budgets below quantify Homewerks 3073-501-WS savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for Homewerks 3073-501-WS (1.8 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,256 gal2,044 gal4,964 gal (~$55)
2 Occupants10,512 gal4,088 gal9,928 gal (~$109)
3 Occupants15,768 gal6,132 gal14,892 gal (~$119–$268)
4 Occupants21,024 gal8,176 gal19,856 gal (~$218)

Which competing models share Homewerks 3073-501-WS flow tier?

Review five peer WaterSense units matching Homewerks 3073-501-WS conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 EBD511TO 1.8 gpm (Same flow) Embellish
Better Homes & Gardens BH27097026121TC 1.8 gpm (Same flow) WaterSense
DANCO 12158 1.8 gpm (Same flow) WaterSense
Design House 547430 1.8 gpm (Same flow) Madison
For Living 063-6530-2 1.8 gpm (Same flow) WaterSense

Can you estimate Homewerks 3073-501-WS payback in your home?

Test how many gallons and dollars Homewerks 3073-501-WS saves each year by entering your household residents and local water-sewer rate below.

Who should not install Homewerks 3073-501-WS in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Homewerks 3073-501-WS for residential use.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Ideal fit: Upgrading 3.5 gpm fixtures for 48.6% water reduction
  • Primary match: Matching Homewerks SKU 3073-501-WS certification on rebate forms

How do federal and code standards apply to Homewerks 3073-501-WS?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Homewerks 3073-501-WS.

Can homeowners claim utility rebates when installing Homewerks 3073-501-WS?

Because Homewerks 3073-501-WS holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is Homewerks 3073-501-WS leaner than typical WaterSense showerhead models?

Compared with the 1.8 gpm WaterSense showerhead median, Homewerks 3073-501-WS's 1.8 gpm rating places it equal to category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with Homewerks 3073-501-WS?

Upgrading a 4.0 gpm legacy fixture to Homewerks 3073-501-WS saves ~19,272 gallons yearly for three occupants, about $212/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with Homewerks 3073-501-WS?

Pairing Homewerks 3073-501-WS (1.8 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.8 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Homewerks 3073-501-WS require a municipal plumbing permit?

Like-for-like swaps using Homewerks 3073-501-WS on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How much water does Homewerks 3073-501-WS save compared with EPAct 1992 and pre-1994 fixtures?

Rated at 1.8 gpm, Homewerks 3073-501-WS cuts 28.0% below the 2.5 gpm EPAct 1992 ceiling and 55.0% under 4.0 gpm legacy units, saving 6,424 gal/person/yr (2,044 vs EPAct).

Who should NOT install Homewerks 3073-501-WS without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.8 gpm showerhead.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories