HOPOPRO H6K025CP WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · H6K025CP (1 SKU)
Verified Specification Summary

Operating at 1.75 gpm, the HOPOPRO H6K025CP showerhead beats 1992 EPAct rules (2.5 gpm) by 30.0% (#3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads), saving a 3-resident home ~15,330 gallons annually compared to 3.5 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for HOPOPRO H6K025CP WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.75 gpm
vs. EPAct 1992
-30.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,110 gal/yr
Annual Saved vs. Legacy
5,110 gal/person
Brand EPA Count
52 showerheads
Series / Variants
H6K025CP (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does HOPOPRO H6K025CP Benchmark & Water Budget show?

WaterSense benchmark: HOPOPRO series H6K025CP (H6K025CP) verifies 1.75 gpm delivery, scoring 30.0% leaner than EPAct 1992 (2.5 gpm) at #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads.

Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: HOPOPRO holds 52 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Tucson - Tucson Water (AZ) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).

How much leaner is HOPOPRO H6K025CP than pre-1994 3.5 gpm plumbing?

Flow distribution bars contrast HOPOPRO H6K025CP (1.75 gpm) directly with the 1.75 gpm WaterSense median and 3.5 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): H6K025CP: 1.75; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)H6K025CP: 1.75H6K025CP1.75EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.75 gpm: 1.75 gpm (53rd percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.75 gpm: 1.75 gpm (P53)

Which framing and flange tolerances matter before installing HOPOPRO H6K025CP?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does HOPOPRO H6K025CP compare to WaterSense category caps?

Each specification row below documents HOPOPRO H6K025CP tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share HOPOPRO (52 certified) EPA WaterSense Partner
Model Number / Series H6K025CP H6K025CP (1 finish variants)
Rated Consumption 1.75 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does HOPOPRO H6K025CP cut?

Calculated annual water budgets below quantify HOPOPRO H6K025CP savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for HOPOPRO H6K025CP (1.75 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,110 gal2,190 gal5,110 gal (~$56)
2 Occupants10,220 gal4,380 gal10,220 gal (~$112)
3 Occupants15,330 gal6,570 gal15,330 gal (~$123–$276)
4 Occupants20,440 gal8,760 gal20,440 gal (~$225)

Which competing models share HOPOPRO H6K025CP flow tier?

Review five peer WaterSense units matching HOPOPRO H6K025CP conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen+roth 5283486 1.75 gpm (Same flow) WaterSense
Axor 38442xx1 1.75 gpm (Same flow) Uno
COBBE KFSCA12102 1.75 gpm (Same flow) KFSCA12102
Current 01932-T 1.75 gpm (Same flow) WaterSense
DORNBRACHT 28.647.970-xx0010 1.75 gpm (Same flow) WaterSense

Can you estimate HOPOPRO H6K025CP payback in your home?

Test how many gallons and dollars HOPOPRO H6K025CP saves each year by entering your household residents and local water-sewer rate below.

When does HOPOPRO H6K025CP fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering HOPOPRO H6K025CP.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Recommended when: Upgrading 3.5 gpm fixtures for 50.0% water reduction
  • Target scenario: Matching HOPOPRO SKU H6K025CP certification on rebate forms

How do federal and code standards apply to HOPOPRO H6K025CP?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for HOPOPRO H6K025CP.

What annual gallon reduction does HOPOPRO H6K025CP achieve over older plumbing?

Testing at 1.75 gpm, HOPOPRO H6K025CP uses 56.2% less water than 4.0 gpm pre-1994 models (30.0% below 2.5 gpm EPAct), conserving 6,570 gallons per resident each year.

When can HOPOPRO H6K025CP (1.75 gpm) underperform in an older bathroom?

Skip HOPOPRO H6K025CP without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat HOPOPRO H6K025CP?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like HOPOPRO H6K025CP, itemized purchase invoices, and residential installation addresses.

How does HOPOPRO H6K025CP perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.75 gpm, HOPOPRO H6K025CP sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to HOPOPRO H6K025CP?

At $11 per 1,000 gallons, a 3-person household conserving 19,710 gallons/yr with HOPOPRO H6K025CP trims roughly $217 annually off water and sewer utility bills.

What anti-scald valve standard pairs with HOPOPRO H6K025CP?

Pairing HOPOPRO H6K025CP (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing HOPOPRO H6K025CP require a municipal plumbing permit?

Like-for-like swaps using HOPOPRO H6K025CP on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories