Skip to main content
Grant Estimator

Hsien Chang Metals Co., Ltd. C26 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Hsien Chang Metals Co., Ltd. (1 SKU)
Verified Specification Summary

The Hsien Chang Metals Co., Ltd. C26 is an EPA WaterSense showerhead certified at 2.0 gpm, 20.0% below EPAct 1992 (2.5 gpm) and #14,982 of 18,544 certified showerheads; tied with 3,562 other certified showerheads at 2.00 gpm. A 3-person household saves ~13,140 gallons/yr replacing a 3.5 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for Hsien Chang Metals Co., Ltd. C26 WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
2.0 gpm
vs. EPAct 1992
-20.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,840 gal/yr
Annual Saved vs. Legacy
4,380 gal/person
Brand EPA Count
14 showerheads
Series / Variants
C26 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Hsien Chang Metals Co., Ltd. C26 Benchmark & Water Budget show?

Flow standing: Hsien Chang Metals Co., Ltd. C26 operates at 2.0 gpm (balanced WaterSense flow tier), #14,982 of 18,544 certified showerheads; tied with 3,562 other certified showerheads at 2.00 gpm (0.25 gpm higher-flow than the 1.75 gpm median), cutting 20.0% off EPAct 1992 (2.5 gpm).

Verify >=30 PSI static water pressure and pair this 2.0 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Hsien Chang Metals Co., Ltd. holds 14 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~13,140 gallons/yr—roughly $105/yr in low-tariff towns ($8/1k gal), $145/yr at national averages ($11/1k gal), or $237/yr in high-rate cities ($18/1k gal). Regional utilities such as City of American Canyon (CA) list active rebates among 200 U.S. programs. Closest alternatives: Alsons 462PB (2.0 gpm) and Aquacubic AF5702-7 (2.0 gpm).

How does Hsien Chang Metals Co., Ltd. C26 compare to EPAct 1992 and legacy gpm rates?

Tested at 2.00 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.5 gpm) and pre-1994 legacy units (3.5 gpm).

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): C26: 2.00; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)C26: 2.00C262.00EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 2.0 gpm: 2 gpm (100th percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm2.0 gpm: 2 gpm (P100)

What floor flatness and flange clearances pair with Hsien Chang Metals Co., Ltd. C26?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which EPA WaterSense test specs apply to Hsien Chang Metals Co., Ltd. C26?

Certified EPA WaterSense records for Hsien Chang Metals Co., Ltd. C26 verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Hsien Chang Metals Co., Ltd. (14 certified) EPA WaterSense Partner
Model Number / Series C26 Certified Series (1 finish variants)
Rated Consumption 2.0 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How much water and money can Hsien Chang Metals Co., Ltd. C26 save each year?

Household projections below calculate Hsien Chang Metals Co., Ltd. C26 annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for Hsien Chang Metals Co., Ltd. C26 (2.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,840 gal1,460 gal4,380 gal (~$48)
2 Occupants11,680 gal2,920 gal8,760 gal (~$96)
3 Occupants17,520 gal4,380 gal13,140 gal (~$105–$237)
4 Occupants23,360 gal5,840 gal17,520 gal (~$193)

Which EPA WaterSense fixtures match Hsien Chang Metals Co., Ltd. C26?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
Alsons 462PB 2.0 gpm (Same flow) WaterSense
Aquacubic AF5702-7 2.0 gpm (Same flow) WaterSense
Aquacubic AF9113-2 2.0 gpm (Same flow) WaterSense
Aquasource 0799969 2.0 gpm (Same flow) AMARI
AquaSource 247101 2.0 gpm (Same flow) WaterSense

How much does Hsien Chang Metals Co., Ltd. C26 save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

When does Hsien Chang Metals Co., Ltd. C26 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Hsien Chang Metals Co., Ltd. C26.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Recommended when: Claiming utility rebates across 200 U.S. WaterSense programs
  • Target scenario: Lowering household draw to 5,840 gal/person/yr

What key rules and numbers govern Hsien Chang Metals Co., Ltd. C26?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Hsien Chang Metals Co., Ltd. C26.

When can Hsien Chang Metals Co., Ltd. C26 (2.0 gpm) underperform in an older bathroom?

Skip Hsien Chang Metals Co., Ltd. C26 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Hsien Chang Metals Co., Ltd. C26?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Hsien Chang Metals Co., Ltd. C26, itemized purchase invoices, and residential installation addresses.

How does Hsien Chang Metals Co., Ltd. C26 perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 2.0 gpm, Hsien Chang Metals Co., Ltd. C26 sits slightly above the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Hsien Chang Metals Co., Ltd. C26?

At $11 per 1,000 gallons, a 3-person household conserving 17,520 gallons/yr with Hsien Chang Metals Co., Ltd. C26 trims roughly $193 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Hsien Chang Metals Co., Ltd. C26?

Pairing Hsien Chang Metals Co., Ltd. C26 (2.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 2.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Hsien Chang Metals Co., Ltd. C26 require a municipal plumbing permit?

Like-for-like swaps using Hsien Chang Metals Co., Ltd. C26 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does Hsien Chang Metals Co., Ltd. C26 achieve over older plumbing?

Testing at 2.0 gpm, Hsien Chang Metals Co., Ltd. C26 uses 50.0% less water than 4.0 gpm pre-1994 models (20.0% below 2.5 gpm EPAct), conserving 5,840 gallons per resident each year.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories