Skip to main content
Grant Estimator

Huayi 9A3421B-WEM24010-6J WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Huayi (1 SKU)
Verified Specification Summary

Homeowners upgrading older 3.5 gpm plumbing to Huayi 9A3421B-WEM24010-6J (1.5 gpm, #559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads) cut 57.1% off legacy draw, conserving ~17,520 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Huayi 9A3421B-WEM24010-6J WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.5 gpm
vs. EPAct 1992
-40.0% (2.5 gpm)
Annual Draw (1 Pers.)
4,380 gal/yr
Annual Saved vs. Legacy
5,840 gal/person
Brand EPA Count
38 showerheads
Series / Variants
9A3421B-WEM24010-6J (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Huayi 9A3421B-WEM24010-6J Benchmark & Water Budget show?

Laboratory testing places Huayi 9A3421B-WEM24010-6J at 1.5 gpm (aggressive sub-1.6 gpm conservation tier), saving 40.0% vs. EPAct 1992 (2.5 gpm) while ranking #559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads (0.25 gpm lower-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.5 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Huayi holds 38 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~17,520 gallons/yr—roughly $140/yr in low-tariff towns ($8/1k gal), $193/yr at national averages ($11/1k gal), or $315/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: Acorn Controls CSH-WSC (1.5 gpm) and ACORN CSH-WSA (1.5 gpm).

How do federal gpm limits contrast with Huayi 9A3421B-WEM24010-6J tested flow?

Each bar isolates Huayi 9A3421B-WEM24010-6J (1.50 gpm) relative to the EPA cap, federal EPAct 1992 standard (2.5 gpm), and pre-1994 draw.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 9A3421B-WEM24010-6J: 1.50; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)9A3421B-WEM24010-6J: 1.509A3421B-WEM24010-6J1.50EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.5 gpm: 1.5 gpm (18th percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.5 gpm: 1.5 gpm (P18)

How does wet-zone tile prep interact with Huayi 9A3421B-WEM24010-6J rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What plumbing standards accompany Huayi 9A3421B-WEM24010-6J installation?

Verify Huayi 9A3421B-WEM24010-6J EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Huayi (38 certified) EPA WaterSense Partner
Model Number / Series 9A3421B-WEM24010-6J Certified Series (1 finish variants)
Rated Consumption 1.5 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

What household water budget fits Huayi 9A3421B-WEM24010-6J?

Annual consumption rows below translate Huayi 9A3421B-WEM24010-6J certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for Huayi 9A3421B-WEM24010-6J (1.5 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant4,380 gal2,920 gal5,840 gal (~$64)
2 Occupants8,760 gal5,840 gal11,680 gal (~$128)
3 Occupants13,140 gal8,760 gal17,520 gal (~$140–$315)
4 Occupants17,520 gal11,680 gal23,360 gal (~$257)

Where can buyers find alternatives to Huayi 9A3421B-WEM24010-6J?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
Acorn Controls CSH-WSC 1.5 gpm (Same flow) WaterSense
ACORN CSH-WSA 1.5 gpm (Same flow) WaterSense
Aquacubic ASH8469 1.5 gpm (Same flow) WaterSense
California Faucet SH-04T.15 1.5 gpm (Same flow) WaterSense
Chi Liu CL-01627-2 1.5 gpm (Same flow) WaterSense

What annual bill drop does Huayi 9A3421B-WEM24010-6J achieve for your family?

Calculate annual gallons conserved and dollar savings for Huayi 9A3421B-WEM24010-6J using your exact occupant count and utility tariff without submitting personal info.

Who should not install Huayi 9A3421B-WEM24010-6J in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Huayi 9A3421B-WEM24010-6J for residential use.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Ideal fit: Meeting 2.5 gpm federal & stricter WaterSense caps
  • Primary match: Targeting ~$193/yr utility savings (3-person home)

Which code checks and cost facts matter for Huayi 9A3421B-WEM24010-6J?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Huayi 9A3421B-WEM24010-6J.

How much water does Huayi 9A3421B-WEM24010-6J save compared with EPAct 1992 and pre-1994 fixtures?

Rated at 1.5 gpm, Huayi 9A3421B-WEM24010-6J cuts 40.0% below the 2.5 gpm EPAct 1992 ceiling and 62.5% under 4.0 gpm legacy units, saving 7,300 gal/person/yr (2,920 vs EPAct).

Who should NOT install Huayi 9A3421B-WEM24010-6J without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.5 gpm showerhead.

Can homeowners claim utility rebates when installing Huayi 9A3421B-WEM24010-6J?

Because Huayi 9A3421B-WEM24010-6J holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is Huayi 9A3421B-WEM24010-6J leaner than typical WaterSense showerhead models?

Compared with the 1.8 gpm WaterSense showerhead median, Huayi 9A3421B-WEM24010-6J's 1.5 gpm rating places it below category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with Huayi 9A3421B-WEM24010-6J?

Upgrading a 4.0 gpm legacy fixture to Huayi 9A3421B-WEM24010-6J saves ~21,900 gallons yearly for three occupants, about $241/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with Huayi 9A3421B-WEM24010-6J?

Pairing Huayi 9A3421B-WEM24010-6J (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Huayi 9A3421B-WEM24010-6J require a municipal plumbing permit?

Like-for-like swaps using Huayi 9A3421B-WEM24010-6J on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories