Verified by EPA WaterSense at 2.0 gpm, Jaclo S161-2.0 sits 20.0% under federal 2.5 gpm ceilings (#14,982 of 18,544 certified showerheads; tied with 3,562 other certified showerheads at 2.00 gpm) and saves ~13,140 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for Jaclo S161-2.0 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 2.0 gpm
- vs. EPAct 1992
- -20.0% (2.5 gpm)
- Annual Draw (1 Pers.)
- 5,840 gal/yr
- Annual Saved vs. Legacy
- 4,380 gal/person
- Brand EPA Count
- 16 showerheads
- Series / Variants
- S161-2.0 (1)

What does Jaclo S161-2.0 Benchmark & Water Budget show?
Under EPA WaterSense protocols, Jaclo S161-2.0 (CYLINDRICO 1) delivers 2.0 gpm (#14,982 of 18,544 certified showerheads; tied with 3,562 other certified showerheads at 2.00 gpm (0.25 gpm higher-flow than the 1.75 gpm median)), beating the 2.5 gpm federal ceiling by 20.0%.
Verify >=30 PSI static water pressure and pair this 2.0 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.
Brand breadth: Jaclo holds 16 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~13,140 gallons/yr—roughly $105/yr in low-tariff towns ($8/1k gal), $145/yr at national averages ($11/1k gal), or $237/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: Alsons 462PB (2.0 gpm) and Aquacubic AF5702-7 (2.0 gpm).
Where does Jaclo S161-2.0 rank among 18,544 certified showerheads?
Review how Jaclo S161-2.0 (2.00 gpm) places inside EPA WaterSense's 18,544-SKU showerhead registry alongside historical 3.5 gpm units.
What plumbing rough-in clearances prevent leaks around Jaclo S161-2.0?
Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.
Which certified attributes define Jaclo S161-2.0 performance?
Official U.S. EPA WaterSense registry entries below confirm Jaclo S161-2.0 rated flow rate, model series status, and household code fit.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Jaclo (16 certified) | EPA WaterSense Partner |
| Model Number / Series | S161-2.0 | CYLINDRICO 1 (1 finish variants) |
| Rated Consumption | 2.0 gpm | Category median 1.75 gpm (n=18,544 rated) |
| Shower / Faucet Pairing | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |
How do Jaclo S161-2.0 savings scale from 1 to 4 occupants?
Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to Jaclo S161-2.0 across different household sizes.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 5,840 gal | 1,460 gal | 4,380 gal (~$48) |
| 2 Occupants | 11,680 gal | 2,920 gal | 8,760 gal (~$96) |
| 3 Occupants | 17,520 gal | 4,380 gal | 13,140 gal (~$105–$237) |
| 4 Occupants | 23,360 gal | 5,840 gal | 17,520 gal (~$193) |
Which peer fixtures deliver flow close to Jaclo S161-2.0?
Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.
| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| Alsons 462PB | 2.0 gpm (Same flow) | WaterSense |
| Aquacubic AF5702-7 | 2.0 gpm (Same flow) | WaterSense |
| Aquacubic AF9113-2 | 2.0 gpm (Same flow) | WaterSense |
| Aquasource 0799969 | 2.0 gpm (Same flow) | AMARI |
| AquaSource 247101 | 2.0 gpm (Same flow) | WaterSense |
Does Jaclo S161-2.0 pay off faster in high-rate cities?
Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark Jaclo S161-2.0 annual savings immediately.
What plumbing or duct constraints rule out Jaclo S161-2.0?
Compare where Jaclo S161-2.0 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Multi-outlet body spray manifold exceeding single-head flow
Best-Fit Homeowner Profiles
- Homeowner profile: Upgrading 3.5 gpm fixtures for 42.9% water reduction
- Suited to: Matching Jaclo SKU S161-2.0 certification on rebate forms
Where do official rules set limits for Jaclo S161-2.0?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Jaclo S161-2.0.
How much does a 3-resident family save yearly switching to Jaclo S161-2.0?
At $11 per 1,000 gallons, a 3-person household conserving 17,520 gallons/yr with Jaclo S161-2.0 trims roughly $193 annually off water and sewer utility bills.
What anti-scald valve standard pairs with Jaclo S161-2.0?
Pairing Jaclo S161-2.0 (2.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.
How is EPA WaterSense performance tested beyond raw gpm flow caps?
EPA WaterSense certification pairs the 2.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.
Does installing Jaclo S161-2.0 require a municipal plumbing permit?
Like-for-like swaps using Jaclo S161-2.0 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
Why upgrade a 4.0 gpm fixture to Jaclo S161-2.0 at 2.0 gpm?
Swapping a 4.0 gpm unit for Jaclo S161-2.0 slashes water draw 50.0% (5,840 gal/person/yr), beating 2.5 gpm federal EPAct standards by 20.0%.
When can Jaclo S161-2.0 (2.0 gpm) underperform in an older bathroom?
Skip Jaclo S161-2.0 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.
How do 133 WaterSense rebate programs treat Jaclo S161-2.0?
Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Jaclo S161-2.0, itemized purchase invoices, and residential installation addresses.
How does Jaclo S161-2.0 perform relative to the EPA WaterSense category median?
Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 2.0 gpm, Jaclo S161-2.0 sits slightly above the category median while clearing federal WaterSense caps.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)