Listed in EPA WaterSense files at 1.75 gpm, Joyrain, YS, Youshi T3200 achieves #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads and lowers household water use ~15,330 gal/yr (3 residents) against pre-1994 3.5 gpm fixtures. Compare EPA WaterSense certified flow metrics for Joyrain, YS, Youshi T3200 WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.75 gpm
- vs. EPAct 1992
- -30.0% (2.5 gpm)
- Annual Draw (1 Pers.)
- 5,110 gal/yr
- Annual Saved vs. Legacy
- 5,110 gal/person
- Brand EPA Count
- 4 showerheads
- Series / Variants
- T3200 (1)

What does Joyrain, YS, Youshi T3200 Benchmark & Water Budget show?
Certified discharge for Joyrain, YS, Youshi T3200 (SHOWER HEAD) measures 1.75 gpm (balanced WaterSense flow tier), standing #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads against the 2.5 gpm standard.
Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.
Brand breadth: Joyrain, YS, Youshi holds 4 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).
Does Joyrain, YS, Youshi T3200 beat the 1.75 gpm WaterSense showerhead median?
Certified at 1.75 gpm, Joyrain, YS, Youshi T3200 sits well under EPAct 1992 limits (2.5 gpm) across 18,544 EPA-registered showerheads.
Why check closet flange height and L/360 stiffness around Joyrain, YS, Youshi T3200?
Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.
Where does Joyrain, YS, Youshi T3200 fit in EPA WaterSense files?
Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for Joyrain, YS, Youshi T3200.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Joyrain, YS, Youshi (4 certified) | EPA WaterSense Partner |
| Model Number / Series | T3200 | SHOWER HEAD (1 finish variants) |
| Rated Consumption | 1.75 gpm | Category median 1.75 gpm (n=18,544 rated) |
| Shower / Faucet Pairing | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |
Does Joyrain, YS, Youshi T3200 lower water bills for larger households?
Review computed annual water totals for 1 to 4 residents comparing Joyrain, YS, Youshi T3200 certified consumption with older pre-1994 residential plumbing hardware.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 5,110 gal | 2,190 gal | 5,110 gal (~$56) |
| 2 Occupants | 10,220 gal | 4,380 gal | 10,220 gal (~$112) |
| 3 Occupants | 15,330 gal | 6,570 gal | 15,330 gal (~$123–$276) |
| 4 Occupants | 20,440 gal | 8,760 gal | 20,440 gal (~$225) |
How do similar WaterSense brands compare with Joyrain, YS, Youshi T3200?
Comparable certified models listed below share Joyrain, YS, Youshi T3200 category standards while offering alternative brand warranties and rough-in configurations.
| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| allen+roth 5283486 | 1.75 gpm (Same flow) | WaterSense |
| Axor 38442xx1 | 1.75 gpm (Same flow) | Uno |
| COBBE KFSCA12102 | 1.75 gpm (Same flow) | KFSCA12102 |
| Current 01932-T | 1.75 gpm (Same flow) | WaterSense |
| DORNBRACHT 28.647.970-xx0010 | 1.75 gpm (Same flow) | WaterSense |
How do local water rates change Joyrain, YS, Youshi T3200 savings?
Use the local browser estimator below with your city water-sewer rate and household size to quantify Joyrain, YS, Youshi T3200 yearly utility impact.
Who should not install Joyrain, YS, Youshi T3200 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Joyrain, YS, Youshi T3200 for residential use.
Limitations & Who Should Skip
- Low static water supply pressure <30 PSI
Best-Fit Homeowner Profiles
- Ideal fit: Claiming utility rebates across 200 U.S. WaterSense programs
- Primary match: Lowering household draw to 5,110 gal/person/yr
What should homeowners verify first about Joyrain, YS, Youshi T3200?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Joyrain, YS, Youshi T3200.
Can homeowners claim utility rebates when installing Joyrain, YS, Youshi T3200?
Because Joyrain, YS, Youshi T3200 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.
Is Joyrain, YS, Youshi T3200 leaner than typical WaterSense showerhead models?
Compared with the 1.8 gpm WaterSense showerhead median, Joyrain, YS, Youshi T3200's 1.75 gpm rating places it below category norms inside EPA conservation limits.
What annual dollar savings can a 3-person home expect with Joyrain, YS, Youshi T3200?
Upgrading a 4.0 gpm legacy fixture to Joyrain, YS, Youshi T3200 saves ~19,710 gallons yearly for three occupants, about $217/yr at $11 per 1,000 gallons combined water and sewer.
What anti-scald valve standard pairs with Joyrain, YS, Youshi T3200?
Pairing Joyrain, YS, Youshi T3200 (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.
How is EPA WaterSense performance tested beyond raw gpm flow caps?
EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.
Does installing Joyrain, YS, Youshi T3200 require a municipal plumbing permit?
Like-for-like swaps using Joyrain, YS, Youshi T3200 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
How much water does Joyrain, YS, Youshi T3200 save compared with EPAct 1992 and pre-1994 fixtures?
Rated at 1.75 gpm, Joyrain, YS, Youshi T3200 cuts 30.0% below the 2.5 gpm EPAct 1992 ceiling and 56.2% under 4.0 gpm legacy units, saving 6,570 gal/person/yr (2,190 vs EPAct).
Who should NOT install Joyrain, YS, Youshi T3200 without checking house plumbing first?
Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.75 gpm showerhead.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)