LEAD ALL A15010 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · LEAD ALL (1 SKU)
Verified Specification Summary

The LEAD ALL A15010 is an EPA WaterSense showerhead certified at 1.8 gpm, 28.0% below EPAct 1992 (2.5 gpm) and #9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads. A 3-person household saves ~14,892 gallons/yr replacing a 3.5 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for LEAD ALL A15010 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.8 gpm
vs. EPAct 1992
-28.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,256 gal/yr
Annual Saved vs. Legacy
4,964 gal/person
Brand EPA Count
6 showerheads
Series / Variants
A15010 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does LEAD ALL A15010 Benchmark & Water Budget show?

Flow standing: LEAD ALL A15010 operates at 1.8 gpm (balanced WaterSense flow tier), #9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads (0.05 gpm higher-flow than the 1.75 gpm median), cutting 28.0% off EPAct 1992 (2.5 gpm).

Verify >=30 PSI static water pressure and pair this 1.8 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: LEAD ALL holds 6 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~14,892 gallons/yr—roughly $119/yr in low-tariff towns ($8/1k gal), $164/yr at national averages ($11/1k gal), or $268/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: 1858 EBD511TO (1.8 gpm) and Better Homes & Gardens BH27097026121TC (1.8 gpm).

How does LEAD ALL A15010 compare to EPAct 1992 and legacy gpm rates?

Tested at 1.80 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.5 gpm) and pre-1994 legacy units (3.5 gpm).

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): A15010: 1.80; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)A15010: 1.80A150101.80EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.8 gpm: 1.8 gpm (81st percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.8 gpm: 1.8 gpm (P81)

What floor flatness and flange clearances pair with LEAD ALL A15010?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which EPA WaterSense test specs apply to LEAD ALL A15010?

Certified EPA WaterSense records for LEAD ALL A15010 verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share LEAD ALL (6 certified) EPA WaterSense Partner
Model Number / Series A15010 Certified Series (1 finish variants)
Rated Consumption 1.8 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How much water and money can LEAD ALL A15010 save each year?

Household projections below calculate LEAD ALL A15010 annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for LEAD ALL A15010 (1.8 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,256 gal2,044 gal4,964 gal (~$55)
2 Occupants10,512 gal4,088 gal9,928 gal (~$109)
3 Occupants15,768 gal6,132 gal14,892 gal (~$119–$268)
4 Occupants21,024 gal8,176 gal19,856 gal (~$218)

Which EPA WaterSense fixtures match LEAD ALL A15010?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 EBD511TO 1.8 gpm (Same flow) Embellish
Better Homes & Gardens BH27097026121TC 1.8 gpm (Same flow) WaterSense
DANCO 12158 1.8 gpm (Same flow) WaterSense
Design House 547430 1.8 gpm (Same flow) Madison
For Living 063-6530-2 1.8 gpm (Same flow) WaterSense

How much does LEAD ALL A15010 save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

When does LEAD ALL A15010 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering LEAD ALL A15010.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Recommended when: Claiming utility rebates across 200 U.S. WaterSense programs
  • Target scenario: Lowering household draw to 5,256 gal/person/yr

What key rules and numbers govern LEAD ALL A15010?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting LEAD ALL A15010.

When can LEAD ALL A15010 (1.8 gpm) underperform in an older bathroom?

Skip LEAD ALL A15010 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat LEAD ALL A15010?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like LEAD ALL A15010, itemized purchase invoices, and residential installation addresses.

How does LEAD ALL A15010 perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.8 gpm, LEAD ALL A15010 sits equal to the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to LEAD ALL A15010?

At $11 per 1,000 gallons, a 3-person household conserving 19,272 gallons/yr with LEAD ALL A15010 trims roughly $212 annually off water and sewer utility bills.

What anti-scald valve standard pairs with LEAD ALL A15010?

Pairing LEAD ALL A15010 (1.8 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.8 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing LEAD ALL A15010 require a municipal plumbing permit?

Like-for-like swaps using LEAD ALL A15010 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does LEAD ALL A15010 achieve over older plumbing?

Testing at 1.8 gpm, LEAD ALL A15010 uses 55.0% less water than 4.0 gpm pre-1994 models (28.0% below 2.5 gpm EPAct), conserving 6,424 gallons per resident each year.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories