Skip to main content
Grant Estimator

Lokby LB-SH-HH-1.1 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Lokby (1 SKU)
Verified Specification Summary

Operating at 1.8 gpm, the Lokby LB-SH-HH-1.1 showerhead beats 1992 EPAct rules (2.5 gpm) by 28.0% (#9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads), saving a 3-resident home ~14,892 gallons annually compared to 3.5 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for Lokby LB-SH-HH-1.1 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.8 gpm
vs. EPAct 1992
-28.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,256 gal/yr
Annual Saved vs. Legacy
4,964 gal/person
Brand EPA Count
2 showerheads
Series / Variants
LB-SH-HH-1.1 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Lokby LB-SH-HH-1.1 Benchmark & Water Budget show?

WaterSense benchmark: Lokby series LB-SH-HH-1.1 verifies 1.8 gpm delivery, scoring 28.0% leaner than EPAct 1992 (2.5 gpm) at #9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads (0.05 gpm higher-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.8 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Lokby holds 2 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~14,892 gallons/yr—roughly $119/yr in low-tariff towns ($8/1k gal), $164/yr at national averages ($11/1k gal), or $268/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: 1858 EBD511TO (1.8 gpm) and Better Homes & Gardens BH27097026121TC (1.8 gpm).

How much leaner is Lokby LB-SH-HH-1.1 than pre-1994 3.5 gpm plumbing?

Flow distribution bars contrast Lokby LB-SH-HH-1.1 (1.80 gpm) directly with the 1.75 gpm WaterSense median and 3.5 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): LB-SH-HH-1.1: 1.80; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)LB-SH-HH-1.1: 1.80LB-SH-HH-1.11.80EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.8 gpm: 1.8 gpm (81st percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.8 gpm: 1.8 gpm (P81)

Which framing and flange tolerances matter before installing Lokby LB-SH-HH-1.1?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does Lokby LB-SH-HH-1.1 compare to WaterSense category caps?

Each specification row below documents Lokby LB-SH-HH-1.1 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Lokby (2 certified) EPA WaterSense Partner
Model Number / Series LB-SH-HH-1.1 Certified Series (1 finish variants)
Rated Consumption 1.8 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does Lokby LB-SH-HH-1.1 cut?

Calculated annual water budgets below quantify Lokby LB-SH-HH-1.1 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for Lokby LB-SH-HH-1.1 (1.8 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,256 gal2,044 gal4,964 gal (~$55)
2 Occupants10,512 gal4,088 gal9,928 gal (~$109)
3 Occupants15,768 gal6,132 gal14,892 gal (~$119–$268)
4 Occupants21,024 gal8,176 gal19,856 gal (~$218)

Which competing models share Lokby LB-SH-HH-1.1 flow tier?

Review five peer WaterSense units matching Lokby LB-SH-HH-1.1 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 EBD511TO 1.8 gpm (Same flow) Embellish
Better Homes & Gardens BH27097026121TC 1.8 gpm (Same flow) WaterSense
DANCO 12158 1.8 gpm (Same flow) WaterSense
Design House 547430 1.8 gpm (Same flow) Madison
For Living 063-6530-2 1.8 gpm (Same flow) WaterSense

Can you estimate Lokby LB-SH-HH-1.1 payback in your home?

Test how many gallons and dollars Lokby LB-SH-HH-1.1 saves each year by entering your household residents and local water-sewer rate below.

Which bath layouts should avoid specifying Lokby LB-SH-HH-1.1?

Match Lokby LB-SH-HH-1.1 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Best for: Upgrading 3.5 gpm fixtures for 48.6% water reduction
  • Optimal use: Matching Lokby SKU LB-SH-HH-1.1 certification on rebate forms

How do federal and code standards apply to Lokby LB-SH-HH-1.1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Lokby LB-SH-HH-1.1.

How does Lokby LB-SH-HH-1.1 cut household water draw versus 1992 federal rules?

Delivering 1.8 gpm, Lokby LB-SH-HH-1.1 trims 2,044 gal/person/yr below 2.5 gpm EPAct caps (28.0% reduction) and 6,424 gal/person/yr under 4.0 gpm legacy fixtures.

What supply pressure checks protect Lokby LB-SH-HH-1.1 spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.8 gpm trim.

Does Lokby LB-SH-HH-1.1 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Lokby LB-SH-HH-1.1 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does Lokby LB-SH-HH-1.1 rank against other certified showerheads?

Rated at 1.8 gpm, Lokby LB-SH-HH-1.1 measures equal to the 1.8 gpm WaterSense showerhead median across thousands of EPA-listed residential fixtures.

Does Lokby LB-SH-HH-1.1 cut utility costs noticeably for a 3-person household?

Yes: cutting 19,272 gallons/yr relative to 4.0 gpm hardware translates to ~$212/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with Lokby LB-SH-HH-1.1?

Pairing Lokby LB-SH-HH-1.1 (1.8 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.8 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Lokby LB-SH-HH-1.1 require a municipal plumbing permit?

Like-for-like swaps using Lokby LB-SH-HH-1.1 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories