Oysdmn 11872-CP WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Oysdmn (1 SKU)
Verified Specification Summary

Verified by EPA WaterSense at 1.75 gpm, Oysdmn 11872-CP sits 30.0% under federal 2.5 gpm ceilings (#3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads) and saves ~15,330 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for Oysdmn 11872-CP WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.75 gpm
vs. EPAct 1992
-30.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,110 gal/yr
Annual Saved vs. Legacy
5,110 gal/person
Brand EPA Count
3 showerheads
Series / Variants
11872-CP (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Oysdmn 11872-CP Benchmark & Water Budget show?

Under EPA WaterSense protocols, Oysdmn 11872-CP delivers 1.75 gpm (#3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads), beating the 2.5 gpm federal ceiling by 30.0%.

Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Oysdmn holds 3 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).

Where does Oysdmn 11872-CP rank among 18,544 certified showerheads?

Review how Oysdmn 11872-CP (1.75 gpm) places inside EPA WaterSense's 18,544-SKU showerhead registry alongside historical 3.5 gpm units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 11872-CP: 1.75; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)11872-CP: 1.7511872-CP1.75EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.75 gpm: 1.75 gpm (53rd percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.75 gpm: 1.75 gpm (P53)

What plumbing rough-in clearances prevent leaks around Oysdmn 11872-CP?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which certified attributes define Oysdmn 11872-CP performance?

Official U.S. EPA WaterSense registry entries below confirm Oysdmn 11872-CP rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Oysdmn (3 certified) EPA WaterSense Partner
Model Number / Series 11872-CP Certified Series (1 finish variants)
Rated Consumption 1.75 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How do Oysdmn 11872-CP savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to Oysdmn 11872-CP across different household sizes.

Computed annual water savings for Oysdmn 11872-CP (1.75 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,110 gal2,190 gal5,110 gal (~$56)
2 Occupants10,220 gal4,380 gal10,220 gal (~$112)
3 Occupants15,330 gal6,570 gal15,330 gal (~$123–$276)
4 Occupants20,440 gal8,760 gal20,440 gal (~$225)

Which peer fixtures deliver flow close to Oysdmn 11872-CP?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen+roth 5283486 1.75 gpm (Same flow) WaterSense
Axor 38442xx1 1.75 gpm (Same flow) Uno
COBBE KFSCA12102 1.75 gpm (Same flow) KFSCA12102
Current 01932-T 1.75 gpm (Same flow) WaterSense
DORNBRACHT 28.647.970-xx0010 1.75 gpm (Same flow) WaterSense

Does Oysdmn 11872-CP pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark Oysdmn 11872-CP annual savings immediately.

When does Oysdmn 11872-CP fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Oysdmn 11872-CP.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Recommended when: Upgrading 3.5 gpm fixtures for 50.0% water reduction
  • Target scenario: Matching Oysdmn SKU 11872-CP certification on rebate forms

Where do official rules set limits for Oysdmn 11872-CP?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Oysdmn 11872-CP.

How do 133 WaterSense rebate programs treat Oysdmn 11872-CP?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Oysdmn 11872-CP, itemized purchase invoices, and residential installation addresses.

How does Oysdmn 11872-CP perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.75 gpm, Oysdmn 11872-CP sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Oysdmn 11872-CP?

At $11 per 1,000 gallons, a 3-person household conserving 19,710 gallons/yr with Oysdmn 11872-CP trims roughly $217 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Oysdmn 11872-CP?

Pairing Oysdmn 11872-CP (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Oysdmn 11872-CP require a municipal plumbing permit?

Like-for-like swaps using Oysdmn 11872-CP on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does Oysdmn 11872-CP achieve over older plumbing?

Testing at 1.75 gpm, Oysdmn 11872-CP uses 56.2% less water than 4.0 gpm pre-1994 models (30.0% below 2.5 gpm EPAct), conserving 6,570 gallons per resident each year.

When can Oysdmn 11872-CP (1.75 gpm) underperform in an older bathroom?

Skip Oysdmn 11872-CP without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.