Skip to main content
Grant Estimator

Pegasus 577-568 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Pegasus (1 SKU)
Verified Specification Summary

Verified by EPA WaterSense at 2.0 gpm, Pegasus 577-568 sits 20.0% under federal 2.5 gpm ceilings (#14,982 of 18,544 certified showerheads; tied with 3,562 other certified showerheads at 2.00 gpm) and saves ~13,140 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for Pegasus 577-568 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
2.0 gpm
vs. EPAct 1992
-20.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,840 gal/yr
Annual Saved vs. Legacy
4,380 gal/person
Brand EPA Count
21 showerheads
Series / Variants
577-568 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Pegasus 577-568 Benchmark & Water Budget show?

Under EPA WaterSense protocols, Pegasus 577-568 delivers 2.0 gpm (#14,982 of 18,544 certified showerheads; tied with 3,562 other certified showerheads at 2.00 gpm (0.25 gpm higher-flow than the 1.75 gpm median)), beating the 2.5 gpm federal ceiling by 20.0%.

Verify >=30 PSI static water pressure and pair this 2.0 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Pegasus holds 21 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~13,140 gallons/yr—roughly $105/yr in low-tariff towns ($8/1k gal), $145/yr at national averages ($11/1k gal), or $237/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: Alsons 462PB (2.0 gpm) and Aquacubic AF5702-7 (2.0 gpm).

Where does Pegasus 577-568 rank among 18,544 certified showerheads?

Review how Pegasus 577-568 (2.00 gpm) places inside EPA WaterSense's 18,544-SKU showerhead registry alongside historical 3.5 gpm units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 577-568: 2.00; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)577-568: 2.00577-5682.00EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 2.0 gpm: 2 gpm (100th percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm2.0 gpm: 2 gpm (P100)

What plumbing rough-in clearances prevent leaks around Pegasus 577-568?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which certified attributes define Pegasus 577-568 performance?

Official U.S. EPA WaterSense registry entries below confirm Pegasus 577-568 rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Pegasus (21 certified) EPA WaterSense Partner
Model Number / Series 577-568 Certified Series (1 finish variants)
Rated Consumption 2.0 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How do Pegasus 577-568 savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to Pegasus 577-568 across different household sizes.

Computed annual water savings for Pegasus 577-568 (2.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,840 gal1,460 gal4,380 gal (~$48)
2 Occupants11,680 gal2,920 gal8,760 gal (~$96)
3 Occupants17,520 gal4,380 gal13,140 gal (~$105–$237)
4 Occupants23,360 gal5,840 gal17,520 gal (~$193)

Which peer fixtures deliver flow close to Pegasus 577-568?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
Alsons 462PB 2.0 gpm (Same flow) WaterSense
Aquacubic AF5702-7 2.0 gpm (Same flow) WaterSense
Aquacubic AF9113-2 2.0 gpm (Same flow) WaterSense
Aquasource 0799969 2.0 gpm (Same flow) AMARI
AquaSource 247101 2.0 gpm (Same flow) WaterSense

Does Pegasus 577-568 pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark Pegasus 577-568 annual savings immediately.

What plumbing or duct constraints rule out Pegasus 577-568?

Compare where Pegasus 577-568 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Homeowner profile: Upgrading 3.5 gpm fixtures for 42.9% water reduction
  • Suited to: Matching Pegasus SKU 577-568 certification on rebate forms

Where do official rules set limits for Pegasus 577-568?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Pegasus 577-568.

When can Pegasus 577-568 (2.0 gpm) underperform in an older bathroom?

Skip Pegasus 577-568 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Pegasus 577-568?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Pegasus 577-568, itemized purchase invoices, and residential installation addresses.

How does Pegasus 577-568 perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 2.0 gpm, Pegasus 577-568 sits slightly above the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Pegasus 577-568?

At $11 per 1,000 gallons, a 3-person household conserving 17,520 gallons/yr with Pegasus 577-568 trims roughly $193 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Pegasus 577-568?

Pairing Pegasus 577-568 (2.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 2.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Pegasus 577-568 require a municipal plumbing permit?

Like-for-like swaps using Pegasus 577-568 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 4.0 gpm fixture to Pegasus 577-568 at 2.0 gpm?

Swapping a 4.0 gpm unit for Pegasus 577-568 slashes water draw 50.0% (5,840 gal/person/yr), beating 2.5 gpm federal EPAct standards by 20.0%.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories