Perrin & Rowe 80126RS1 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Perrin & Rowe (1 SKU)
Verified Specification Summary

Operating at 1.75 gpm, the Perrin & Rowe 80126RS1 showerhead beats 1992 EPAct rules (2.5 gpm) by 30.0% (#3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads), saving a 3-resident home ~15,330 gallons annually compared to 3.5 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for Perrin & Rowe 80126RS1 WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.75 gpm
vs. EPAct 1992
-30.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,110 gal/yr
Annual Saved vs. Legacy
5,110 gal/person
Brand EPA Count
21 showerheads
Series / Variants
80126RS1 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Perrin & Rowe 80126RS1 Benchmark & Water Budget show?

WaterSense benchmark: Perrin & Rowe series 80126RS1 verifies 1.75 gpm delivery, scoring 30.0% leaner than EPAct 1992 (2.5 gpm) at #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads.

Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Perrin & Rowe holds 21 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).

How much leaner is Perrin & Rowe 80126RS1 than pre-1994 3.5 gpm plumbing?

Flow distribution bars contrast Perrin & Rowe 80126RS1 (1.75 gpm) directly with the 1.75 gpm WaterSense median and 3.5 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 80126RS1: 1.75; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)80126RS1: 1.7580126RS11.75EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.75 gpm: 1.75 gpm (53rd percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.75 gpm: 1.75 gpm (P53)

Which framing and flange tolerances matter before installing Perrin & Rowe 80126RS1?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does Perrin & Rowe 80126RS1 compare to WaterSense category caps?

Each specification row below documents Perrin & Rowe 80126RS1 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Perrin & Rowe (21 certified) EPA WaterSense Partner
Model Number / Series 80126RS1 Certified Series (1 finish variants)
Rated Consumption 1.75 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does Perrin & Rowe 80126RS1 cut?

Calculated annual water budgets below quantify Perrin & Rowe 80126RS1 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for Perrin & Rowe 80126RS1 (1.75 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,110 gal2,190 gal5,110 gal (~$56)
2 Occupants10,220 gal4,380 gal10,220 gal (~$112)
3 Occupants15,330 gal6,570 gal15,330 gal (~$123–$276)
4 Occupants20,440 gal8,760 gal20,440 gal (~$225)

Which competing models share Perrin & Rowe 80126RS1 flow tier?

Review five peer WaterSense units matching Perrin & Rowe 80126RS1 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen+roth 5283486 1.75 gpm (Same flow) WaterSense
Axor 38442xx1 1.75 gpm (Same flow) Uno
COBBE KFSCA12102 1.75 gpm (Same flow) KFSCA12102
Current 01932-T 1.75 gpm (Same flow) WaterSense
DORNBRACHT 28.647.970-xx0010 1.75 gpm (Same flow) WaterSense

Can you estimate Perrin & Rowe 80126RS1 payback in your home?

Test how many gallons and dollars Perrin & Rowe 80126RS1 saves each year by entering your household residents and local water-sewer rate below.

Where should contractors skip Perrin & Rowe 80126RS1 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Perrin & Rowe 80126RS1 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Choose this if: Upgrading 3.5 gpm fixtures for 50.0% water reduction
  • Works well for: Matching Perrin & Rowe SKU 80126RS1 certification on rebate forms

How do federal and code standards apply to Perrin & Rowe 80126RS1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Perrin & Rowe 80126RS1.

Is Perrin & Rowe 80126RS1 leaner than typical WaterSense showerhead models?

Compared with the 1.8 gpm WaterSense showerhead median, Perrin & Rowe 80126RS1's 1.75 gpm rating places it below category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with Perrin & Rowe 80126RS1?

Upgrading a 4.0 gpm legacy fixture to Perrin & Rowe 80126RS1 saves ~19,710 gallons yearly for three occupants, about $217/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with Perrin & Rowe 80126RS1?

Pairing Perrin & Rowe 80126RS1 (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Perrin & Rowe 80126RS1 require a municipal plumbing permit?

Like-for-like swaps using Perrin & Rowe 80126RS1 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How many gallons per person does Perrin & Rowe 80126RS1 save annually?

Each resident saves ~6,570 gallons yearly (56.2% drop) replacing a 4.0 gpm fixture with Perrin & Rowe 80126RS1 (1.75 gpm), or 2,190 gal/yr versus 2.5 gpm EPAct baselines.

Who should NOT install Perrin & Rowe 80126RS1 without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.75 gpm showerhead.

Can homeowners claim utility rebates when installing Perrin & Rowe 80126RS1?

Because Perrin & Rowe 80126RS1 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.