Skip to main content
Grant Estimator

PROFLO®, PFHS232 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · PROFLO®, (1 SKU)
Verified Specification Summary

Operating at 1.25 gpm, the PROFLO®, PFHS232 showerhead beats 1992 EPAct rules (2.5 gpm) by 50.0% (#56 of 18,544 certified showerheads; most water-efficient 3.0% of 18,544 certified showerheads, lower-flow than 97.0% of certified showerheads), saving a 3-resident home ~19,710 gallons annually compared to 3.5 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for PROFLO®, PFHS232 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.25 gpm
vs. EPAct 1992
-50.0% (2.5 gpm)
Annual Draw (1 Pers.)
3,650 gal/yr
Annual Saved vs. Legacy
6,570 gal/person
Brand EPA Count
3 showerheads
Series / Variants
PFHS232 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does PROFLO®, PFHS232 Benchmark & Water Budget show?

WaterSense benchmark: PROFLO®, series PFHS232 verifies 1.25 gpm delivery, scoring 50.0% leaner than EPAct 1992 (2.5 gpm) at #56 of 18,544 certified showerheads; most water-efficient 3.0% of 18,544 certified showerheads, lower-flow than 97.0% of certified showerheads (0.50 gpm lower-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.25 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: PROFLO®, holds 3 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~19,710 gallons/yr—roughly $158/yr in low-tariff towns ($8/1k gal), $217/yr at national averages ($11/1k gal), or $355/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: ECO-LOGICAL B125-CH (1.25 gpm) and ECO-LOGICAL B125-W (1.25 gpm).

How much leaner is PROFLO®, PFHS232 than pre-1994 3.5 gpm plumbing?

Flow distribution bars contrast PROFLO®, PFHS232 (1.25 gpm) directly with the 1.75 gpm WaterSense median and 3.5 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): PFHS232: 1.25; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)PFHS232: 1.25PFHS2321.25EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.25 gpm: 1.25 gpm (3rd percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.25 gpm: 1.25 gpm (P3)

Which framing and flange tolerances matter before installing PROFLO®, PFHS232?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does PROFLO®, PFHS232 compare to WaterSense category caps?

Each specification row below documents PROFLO®, PFHS232 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share PROFLO®, (3 certified) EPA WaterSense Partner
Model Number / Series PFHS232 Certified Series (1 finish variants)
Rated Consumption 1.25 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does PROFLO®, PFHS232 cut?

Calculated annual water budgets below quantify PROFLO®, PFHS232 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for PROFLO®, PFHS232 (1.25 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant3,650 gal3,650 gal6,570 gal (~$72)
2 Occupants7,300 gal7,300 gal13,140 gal (~$145)
3 Occupants10,950 gal10,950 gal19,710 gal (~$158–$355)
4 Occupants14,600 gal14,600 gal26,280 gal (~$289)

Which competing models share PROFLO®, PFHS232 flow tier?

Review five peer WaterSense units matching PROFLO®, PFHS232 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
ECO-LOGICAL B125-CH 1.25 gpm (Same flow) Showerhead
ECO-LOGICAL B125-W 1.25 gpm (Same flow) Showerhead
EVOLVE/AM EV3019-BN125-FB 1.25 gpm (Same flow) Showerhead
EVOLVE/AM EV3019-CP125-FB 1.25 gpm (Same flow) Showerhead
EVOLVE/AM EV3019-MB125-FB 1.25 gpm (Same flow) Showerhead

Can you estimate PROFLO®, PFHS232 payback in your home?

Test how many gallons and dollars PROFLO®, PFHS232 saves each year by entering your household residents and local water-sewer rate below.

Does PROFLO®, PFHS232 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying PROFLO®, PFHS232 for your remodel.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Strong scenario: Upgrading 3.5 gpm fixtures for 64.3% water reduction
  • Best application: Matching PROFLO®, SKU PFHS232 certification on rebate forms

How do federal and code standards apply to PROFLO®, PFHS232?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for PROFLO®, PFHS232.

Does PROFLO®, PFHS232 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes PROFLO®, PFHS232 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does PROFLO®, PFHS232 rank against other certified showerheads?

Rated at 1.25 gpm, PROFLO®, PFHS232 measures below the 1.8 gpm WaterSense showerhead median across thousands of EPA-listed residential fixtures.

Does PROFLO®, PFHS232 cut utility costs noticeably for a 3-person household?

Yes: cutting 24,090 gallons/yr relative to 4.0 gpm hardware translates to ~$265/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with PROFLO®, PFHS232?

Pairing PROFLO®, PFHS232 (1.25 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.25 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing PROFLO®, PFHS232 require a municipal plumbing permit?

Like-for-like swaps using PROFLO®, PFHS232 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What efficiency edge separates PROFLO®, PFHS232 from legacy and EPAct models?

Certified at 1.25 gpm, PROFLO®, PFHS232 achieves 50.0% savings against EPAct 1992 (2.5 gpm) and 68.8% savings against 4.0 gpm fixtures, 8,030 gallons per occupant yearly.

What supply pressure checks protect PROFLO®, PFHS232 spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.25 gpm trim.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories