Skip to main content
Grant Estimator

Project Source F201E521 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Rutland (2 SKUs)
Verified Specification Summary

The Project Source F201E521 is an EPA WaterSense showerhead certified at 1.75 gpm, 30.0% below EPAct 1992 (2.5 gpm) and #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads. A 3-person household saves ~15,330 gallons/yr replacing a 3.5 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for Project Source F201E521 WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.75 gpm
vs. EPAct 1992
-30.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,110 gal/yr
Annual Saved vs. Legacy
5,110 gal/person
Brand EPA Count
81 showerheads
Series / Variants
F201E521 (2)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Project Source F201E521 Benchmark & Water Budget show?

Flow standing: Project Source F201E521 (Rutland) operates at 1.75 gpm (balanced WaterSense flow tier), #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads, cutting 30.0% off EPAct 1992 (2.5 gpm).

Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Project Source holds 81 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).

How does Project Source F201E521 compare to EPAct 1992 and legacy gpm rates?

Tested at 1.75 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.5 gpm) and pre-1994 legacy units (3.5 gpm).

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): F201E521: 1.75; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)F201E521: 1.75F201E5211.75EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.75 gpm: 1.75 gpm (53rd percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.75 gpm: 1.75 gpm (P53)

What floor flatness and flange clearances pair with Project Source F201E521?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which EPA WaterSense test specs apply to Project Source F201E521?

Certified EPA WaterSense records for Project Source F201E521 verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Project Source (81 certified) EPA WaterSense Partner
Model Number / Series F201E521 Rutland (2 finish variants)
Rated Consumption 1.75 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 2 finish and trim SKUs share the Project Source F201E521 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 2 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Project Source F201E521 (2 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
F201E521**1.75 gpmRutland
F201E514**1.75 gpmRutland

How much water and money can Project Source F201E521 save each year?

Household projections below calculate Project Source F201E521 annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for Project Source F201E521 (1.75 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,110 gal2,190 gal5,110 gal (~$56)
2 Occupants10,220 gal4,380 gal10,220 gal (~$112)
3 Occupants15,330 gal6,570 gal15,330 gal (~$123–$276)
4 Occupants20,440 gal8,760 gal20,440 gal (~$225)

Which EPA WaterSense fixtures match Project Source F201E521?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen+roth 5283486 1.75 gpm (Same flow) WaterSense
Axor 38442xx1 1.75 gpm (Same flow) Uno
COBBE KFSCA12102 1.75 gpm (Same flow) KFSCA12102
Current 01932-T 1.75 gpm (Same flow) WaterSense
DORNBRACHT 28.647.970-xx0010 1.75 gpm (Same flow) WaterSense

How much does Project Source F201E521 save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

Which bath layouts should avoid specifying Project Source F201E521?

Match Project Source F201E521 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Best for: Claiming utility rebates across 200 U.S. WaterSense programs
  • Optimal use: Lowering household draw to 5,110 gal/person/yr

What key rules and numbers govern Project Source F201E521?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Project Source F201E521.

Does Project Source F201E521 cut utility costs noticeably for a 3-person household?

Yes: cutting 19,710 gallons/yr relative to 4.0 gpm hardware translates to ~$217/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with Project Source F201E521?

Pairing Project Source F201E521 (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Project Source F201E521 require a municipal plumbing permit?

Like-for-like swaps using Project Source F201E521 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How does Project Source F201E521 cut household water draw versus 1992 federal rules?

Delivering 1.75 gpm, Project Source F201E521 trims 2,190 gal/person/yr below 2.5 gpm EPAct caps (30.0% reduction) and 6,570 gal/person/yr under 4.0 gpm legacy fixtures.

What supply pressure checks protect Project Source F201E521 spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.75 gpm trim.

Does Project Source F201E521 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Project Source F201E521 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does Project Source F201E521 rank against other certified showerheads?

Rated at 1.75 gpm, Project Source F201E521 measures below the 1.8 gpm WaterSense showerhead median across thousands of EPA-listed residential fixtures.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories