Skip to main content
Grant Estimator

RICH FULL 02C WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · RICH FULL (1 SKU)
Verified Specification Summary

Listed in EPA WaterSense files at 1.75 gpm, RICH FULL 02C achieves #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads and lowers household water use ~15,330 gal/yr (3 residents) against pre-1994 3.5 gpm fixtures. Compare EPA WaterSense certified flow metrics for RICH FULL 02C WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.75 gpm
vs. EPAct 1992
-30.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,110 gal/yr
Annual Saved vs. Legacy
5,110 gal/person
Brand EPA Count
21 showerheads
Series / Variants
02C (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does RICH FULL 02C Benchmark & Water Budget show?

Certified discharge for RICH FULL 02C measures 1.75 gpm (balanced WaterSense flow tier), standing #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads against the 2.5 gpm standard.

Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: RICH FULL holds 21 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).

Does RICH FULL 02C beat the 1.75 gpm WaterSense showerhead median?

Certified at 1.75 gpm, RICH FULL 02C sits well under EPAct 1992 limits (2.5 gpm) across 18,544 EPA-registered showerheads.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 02C: 1.75; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)02C: 1.7502C1.75EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.75 gpm: 1.75 gpm (53rd percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.75 gpm: 1.75 gpm (P53)

Why check closet flange height and L/360 stiffness around RICH FULL 02C?

Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Where does RICH FULL 02C fit in EPA WaterSense files?

Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for RICH FULL 02C.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share RICH FULL (21 certified) EPA WaterSense Partner
Model Number / Series 02C Certified Series (1 finish variants)
Rated Consumption 1.75 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Does RICH FULL 02C lower water bills for larger households?

Review computed annual water totals for 1 to 4 residents comparing RICH FULL 02C certified consumption with older pre-1994 residential plumbing hardware.

Computed annual water savings for RICH FULL 02C (1.75 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,110 gal2,190 gal5,110 gal (~$56)
2 Occupants10,220 gal4,380 gal10,220 gal (~$112)
3 Occupants15,330 gal6,570 gal15,330 gal (~$123–$276)
4 Occupants20,440 gal8,760 gal20,440 gal (~$225)

How do similar WaterSense brands compare with RICH FULL 02C?

Comparable certified models listed below share RICH FULL 02C category standards while offering alternative brand warranties and rough-in configurations.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen+roth 5283486 1.75 gpm (Same flow) WaterSense
Axor 38442xx1 1.75 gpm (Same flow) Uno
COBBE KFSCA12102 1.75 gpm (Same flow) KFSCA12102
Current 01932-T 1.75 gpm (Same flow) WaterSense
DORNBRACHT 28.647.970-xx0010 1.75 gpm (Same flow) WaterSense

How do local water rates change RICH FULL 02C savings?

Use the local browser estimator below with your city water-sewer rate and household size to quantify RICH FULL 02C yearly utility impact.

Does RICH FULL 02C suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying RICH FULL 02C for your remodel.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Strong scenario: Claiming utility rebates across 200 U.S. WaterSense programs
  • Best application: Lowering household draw to 5,110 gal/person/yr

What should homeowners verify first about RICH FULL 02C?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to RICH FULL 02C.

What efficiency edge separates RICH FULL 02C from legacy and EPAct models?

Certified at 1.75 gpm, RICH FULL 02C achieves 30.0% savings against EPAct 1992 (2.5 gpm) and 56.2% savings against 4.0 gpm fixtures, 6,570 gallons per occupant yearly.

What supply pressure checks protect RICH FULL 02C spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.75 gpm trim.

Does RICH FULL 02C qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes RICH FULL 02C eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does RICH FULL 02C rank against other certified showerheads?

Rated at 1.75 gpm, RICH FULL 02C measures below the 1.8 gpm WaterSense showerhead median across thousands of EPA-listed residential fixtures.

Does RICH FULL 02C cut utility costs noticeably for a 3-person household?

Yes: cutting 19,710 gallons/yr relative to 4.0 gpm hardware translates to ~$217/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with RICH FULL 02C?

Pairing RICH FULL 02C (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing RICH FULL 02C require a municipal plumbing permit?

Like-for-like swaps using RICH FULL 02C on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories