Skip to main content
Grant Estimator

Sherle Wagner International 101WLMT WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Sherle Wagner International (1 SKU)
Verified Specification Summary

Homeowners upgrading older 3.5 gpm plumbing to Sherle Wagner International 101WLMT (1.5 gpm, #559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads) cut 57.1% off legacy draw, conserving ~17,520 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Sherle Wagner International 101WLMT WaterSense, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.5 gpm
vs. EPAct 1992
-40.0% (2.5 gpm)
Annual Draw (1 Pers.)
4,380 gal/yr
Annual Saved vs. Legacy
5,840 gal/person
Brand EPA Count
12 showerheads
Series / Variants
101WLMT (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Sherle Wagner International 101WLMT Benchmark & Water Budget show?

Laboratory testing places Sherle Wagner International 101WLMT at 1.5 gpm (aggressive sub-1.6 gpm conservation tier), saving 40.0% vs. EPAct 1992 (2.5 gpm) while ranking #559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads (0.25 gpm lower-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.5 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Sherle Wagner International holds 12 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~17,520 gallons/yr—roughly $140/yr in low-tariff towns ($8/1k gal), $193/yr at national averages ($11/1k gal), or $315/yr in high-rate cities ($18/1k gal). Regional utilities such as Liberty Utilities - Arizona (AZ) list active rebates among 200 U.S. programs. Closest alternatives: Acorn Controls CSH-WSC (1.5 gpm) and ACORN CSH-WSA (1.5 gpm).

How do federal gpm limits contrast with Sherle Wagner International 101WLMT tested flow?

Each bar isolates Sherle Wagner International 101WLMT (1.50 gpm) relative to the EPA cap, federal EPAct 1992 standard (2.5 gpm), and pre-1994 draw.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 101WLMT: 1.50; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)101WLMT: 1.50101WLMT1.50EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.5 gpm: 1.5 gpm (18th percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.5 gpm: 1.5 gpm (P18)

How does wet-zone tile prep interact with Sherle Wagner International 101WLMT rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What plumbing standards accompany Sherle Wagner International 101WLMT installation?

Verify Sherle Wagner International 101WLMT EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Sherle Wagner International (12 certified) EPA WaterSense Partner
Model Number / Series 101WLMT Certified Series (1 finish variants)
Rated Consumption 1.5 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

What household water budget fits Sherle Wagner International 101WLMT?

Annual consumption rows below translate Sherle Wagner International 101WLMT certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for Sherle Wagner International 101WLMT (1.5 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant4,380 gal2,920 gal5,840 gal (~$64)
2 Occupants8,760 gal5,840 gal11,680 gal (~$128)
3 Occupants13,140 gal8,760 gal17,520 gal (~$140–$315)
4 Occupants17,520 gal11,680 gal23,360 gal (~$257)

Where can buyers find alternatives to Sherle Wagner International 101WLMT?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
Acorn Controls CSH-WSC 1.5 gpm (Same flow) WaterSense
ACORN CSH-WSA 1.5 gpm (Same flow) WaterSense
Aquacubic ASH8469 1.5 gpm (Same flow) WaterSense
California Faucet SH-04T.15 1.5 gpm (Same flow) WaterSense
Chi Liu CL-01627-2 1.5 gpm (Same flow) WaterSense

What annual bill drop does Sherle Wagner International 101WLMT achieve for your family?

Calculate annual gallons conserved and dollar savings for Sherle Wagner International 101WLMT using your exact occupant count and utility tariff without submitting personal info.

When does Sherle Wagner International 101WLMT fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Sherle Wagner International 101WLMT.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Recommended when: Meeting 2.5 gpm federal & stricter WaterSense caps
  • Target scenario: Targeting ~$193/yr utility savings (3-person home)

Which code checks and cost facts matter for Sherle Wagner International 101WLMT?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Sherle Wagner International 101WLMT.

How much does a 3-resident family save yearly switching to Sherle Wagner International 101WLMT?

At $11 per 1,000 gallons, a 3-person household conserving 21,900 gallons/yr with Sherle Wagner International 101WLMT trims roughly $241 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Sherle Wagner International 101WLMT?

Pairing Sherle Wagner International 101WLMT (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Sherle Wagner International 101WLMT require a municipal plumbing permit?

Like-for-like swaps using Sherle Wagner International 101WLMT on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does Sherle Wagner International 101WLMT achieve over older plumbing?

Testing at 1.5 gpm, Sherle Wagner International 101WLMT uses 62.5% less water than 4.0 gpm pre-1994 models (40.0% below 2.5 gpm EPAct), conserving 7,300 gallons per resident each year.

When can Sherle Wagner International 101WLMT (1.5 gpm) underperform in an older bathroom?

Skip Sherle Wagner International 101WLMT without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Sherle Wagner International 101WLMT?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Sherle Wagner International 101WLMT, itemized purchase invoices, and residential installation addresses.

How does Sherle Wagner International 101WLMT perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.5 gpm, Sherle Wagner International 101WLMT sits below the category median while clearing federal WaterSense caps.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories