Skip to main content
Grant Estimator

Sloan Valve Company AC-460-1.8 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Act-O-Matic® (2 SKUs)
Verified Specification Summary

Operating at 1.8 gpm, the Sloan Valve Company AC-460-1.8 showerhead beats 1992 EPAct rules (2.5 gpm) by 28.0% (#9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads), saving a 3-resident home ~14,892 gallons annually compared to 3.5 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for Sloan Valve Company AC-460-1.8 WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.8 gpm
vs. EPAct 1992
-28.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,256 gal/yr
Annual Saved vs. Legacy
4,964 gal/person
Brand EPA Count
2 showerheads
Series / Variants
AC-460-1.8 (2)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Sloan Valve Company AC-460-1.8 Benchmark & Water Budget show?

WaterSense benchmark: Sloan Valve Company series AC-460-1.8 (Act-O-Matic®) verifies 1.8 gpm delivery, scoring 28.0% leaner than EPAct 1992 (2.5 gpm) at #9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads (0.05 gpm higher-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.8 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Sloan Valve Company holds 2 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~14,892 gallons/yr—roughly $119/yr in low-tariff towns ($8/1k gal), $164/yr at national averages ($11/1k gal), or $268/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 EBD511TO (1.8 gpm) and Better Homes & Gardens BH27097026121TC (1.8 gpm).

How much leaner is Sloan Valve Company AC-460-1.8 than pre-1994 3.5 gpm plumbing?

Flow distribution bars contrast Sloan Valve Company AC-460-1.8 (1.80 gpm) directly with the 1.75 gpm WaterSense median and 3.5 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): AC-460-1.8: 1.80; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)AC-460-1.8: 1.80AC-460-1.81.80EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.8 gpm: 1.8 gpm (81st percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.8 gpm: 1.8 gpm (P81)

Which framing and flange tolerances matter before installing Sloan Valve Company AC-460-1.8?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does Sloan Valve Company AC-460-1.8 compare to WaterSense category caps?

Each specification row below documents Sloan Valve Company AC-460-1.8 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Sloan Valve Company (2 certified) EPA WaterSense Partner
Model Number / Series AC-460-1.8 Act-O-Matic® (2 finish variants)
Rated Consumption 1.8 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 2 finish and trim SKUs share the Sloan Valve Company AC-460-1.8 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 2 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Sloan Valve Company AC-460-1.8 (2 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
AC-460-1.81.8 gpmAct-O-Matic®
AC-450-1.81.8 gpmAct-O-Matic®

How many gallons per year does Sloan Valve Company AC-460-1.8 cut?

Calculated annual water budgets below quantify Sloan Valve Company AC-460-1.8 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for Sloan Valve Company AC-460-1.8 (1.8 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,256 gal2,044 gal4,964 gal (~$55)
2 Occupants10,512 gal4,088 gal9,928 gal (~$109)
3 Occupants15,768 gal6,132 gal14,892 gal (~$119–$268)
4 Occupants21,024 gal8,176 gal19,856 gal (~$218)

Which competing models share Sloan Valve Company AC-460-1.8 flow tier?

Review five peer WaterSense units matching Sloan Valve Company AC-460-1.8 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 EBD511TO 1.8 gpm (Same flow) Embellish
Better Homes & Gardens BH27097026121TC 1.8 gpm (Same flow) WaterSense
DANCO 12158 1.8 gpm (Same flow) WaterSense
Design House 547430 1.8 gpm (Same flow) Madison
For Living 063-6530-2 1.8 gpm (Same flow) WaterSense

Can you estimate Sloan Valve Company AC-460-1.8 payback in your home?

Test how many gallons and dollars Sloan Valve Company AC-460-1.8 saves each year by entering your household residents and local water-sewer rate below.

Does Sloan Valve Company AC-460-1.8 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Sloan Valve Company AC-460-1.8 for your remodel.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Strong scenario: Upgrading 3.5 gpm fixtures for 48.6% water reduction
  • Best application: Matching Sloan Valve Company SKU AC-460-1.8 certification on rebate forms

How do federal and code standards apply to Sloan Valve Company AC-460-1.8?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Sloan Valve Company AC-460-1.8.

What efficiency edge separates Sloan Valve Company AC-460-1.8 from legacy and EPAct models?

Certified at 1.8 gpm, Sloan Valve Company AC-460-1.8 achieves 28.0% savings against EPAct 1992 (2.5 gpm) and 55.0% savings against 4.0 gpm fixtures, 6,424 gallons per occupant yearly.

What supply pressure checks protect Sloan Valve Company AC-460-1.8 spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.8 gpm trim.

Does Sloan Valve Company AC-460-1.8 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Sloan Valve Company AC-460-1.8 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does Sloan Valve Company AC-460-1.8 rank against other certified showerheads?

Rated at 1.8 gpm, Sloan Valve Company AC-460-1.8 measures equal to the 1.8 gpm WaterSense showerhead median across thousands of EPA-listed residential fixtures.

Does Sloan Valve Company AC-460-1.8 cut utility costs noticeably for a 3-person household?

Yes: cutting 19,272 gallons/yr relative to 4.0 gpm hardware translates to ~$212/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with Sloan Valve Company AC-460-1.8?

Pairing Sloan Valve Company AC-460-1.8 (1.8 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.8 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Sloan Valve Company AC-460-1.8 require a municipal plumbing permit?

Like-for-like swaps using Sloan Valve Company AC-460-1.8 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories