Skip to main content
Grant Estimator

SPARKPOD FSH-V2-BM WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · FILTERED SHOWER HEAD, Matte Black (1 SKU)
Verified Specification Summary

Certified under EPA WaterSense, SPARKPOD FSH-V2-BM tests at 1.8 gpm (#9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads), trimming 28.0% off the 2.5 gpm federal cap while cutting 3-person household draw by ~14,892 gal/yr versus 3.5 gpm fixtures. Compare EPA WaterSense certified flow metrics for SPARKPOD FSH-V2-BM WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.8 gpm
vs. EPAct 1992
-28.0% (2.5 gpm)
Annual Draw (1 Pers.)
5,256 gal/yr
Annual Saved vs. Legacy
4,964 gal/person
Brand EPA Count
11 showerheads
Series / Variants
FSH-V2-BM (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does SPARKPOD FSH-V2-BM Benchmark & Water Budget show?

Efficiency check: certified at 1.8 gpm, SPARKPOD FSH-V2-BM (FILTERED SHOWER HEAD, Matte Black) trims 28.0% under federal 2.5 gpm caps; #9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads (0.05 gpm higher-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.8 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: SPARKPOD holds 11 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~14,892 gallons/yr—roughly $119/yr in low-tariff towns ($8/1k gal), $164/yr at national averages ($11/1k gal), or $268/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: 1858 EBD511TO (1.8 gpm) and Better Homes & Gardens BH27097026121TC (1.8 gpm).

Where does SPARKPOD FSH-V2-BM sit on the EPA WaterSense showerhead flow curve?

Comparing SPARKPOD FSH-V2-BM (1.80 gpm) against federal EPAct (2.5 gpm) and legacy (3.5 gpm) baselines shows immediate per-use conservation.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): FSH-V2-BM: 1.80; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)FSH-V2-BM: 1.80FSH-V2-BM1.80EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.8 gpm: 1.8 gpm (81st percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.8 gpm: 1.8 gpm (P81)

How do subfloor levelness and rough-in height protect SPARKPOD FSH-V2-BM?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What official WaterSense figures verify SPARKPOD FSH-V2-BM?

Examine SPARKPOD FSH-V2-BM certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share SPARKPOD (11 certified) EPA WaterSense Partner
Model Number / Series FSH-V2-BM FILTERED SHOWER HEAD, Matte Black (1 finish variants)
Rated Consumption 1.8 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

What annual utility savings does SPARKPOD FSH-V2-BM deliver?

Compare 1-to-4-person household water use with SPARKPOD FSH-V2-BM against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for SPARKPOD FSH-V2-BM (1.8 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant5,256 gal2,044 gal4,964 gal (~$55)
2 Occupants10,512 gal4,088 gal9,928 gal (~$109)
3 Occupants15,768 gal6,132 gal14,892 gal (~$119–$268)
4 Occupants21,024 gal8,176 gal19,856 gal (~$218)

What alternative WaterSense models compare to SPARKPOD FSH-V2-BM?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 EBD511TO 1.8 gpm (Same flow) Embellish
Better Homes & Gardens BH27097026121TC 1.8 gpm (Same flow) WaterSense
DANCO 12158 1.8 gpm (Same flow) WaterSense
Design House 547430 1.8 gpm (Same flow) Madison
For Living 063-6530-2 1.8 gpm (Same flow) WaterSense

What will SPARKPOD FSH-V2-BM save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

When does SPARKPOD FSH-V2-BM fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering SPARKPOD FSH-V2-BM.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Recommended when: Meeting 2.5 gpm federal & stricter WaterSense caps
  • Target scenario: Targeting ~$164/yr utility savings (3-person home)

Which homeowner questions come up most for SPARKPOD FSH-V2-BM?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around SPARKPOD FSH-V2-BM.

How does SPARKPOD FSH-V2-BM perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.8 gpm, SPARKPOD FSH-V2-BM sits equal to the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to SPARKPOD FSH-V2-BM?

At $11 per 1,000 gallons, a 3-person household conserving 19,272 gallons/yr with SPARKPOD FSH-V2-BM trims roughly $212 annually off water and sewer utility bills.

What anti-scald valve standard pairs with SPARKPOD FSH-V2-BM?

Pairing SPARKPOD FSH-V2-BM (1.8 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.8 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing SPARKPOD FSH-V2-BM require a municipal plumbing permit?

Like-for-like swaps using SPARKPOD FSH-V2-BM on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does SPARKPOD FSH-V2-BM achieve over older plumbing?

Testing at 1.8 gpm, SPARKPOD FSH-V2-BM uses 55.0% less water than 4.0 gpm pre-1994 models (28.0% below 2.5 gpm EPAct), conserving 6,424 gallons per resident each year.

When can SPARKPOD FSH-V2-BM (1.8 gpm) underperform in an older bathroom?

Skip SPARKPOD FSH-V2-BM without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat SPARKPOD FSH-V2-BM?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like SPARKPOD FSH-V2-BM, itemized purchase invoices, and residential installation addresses.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories