Certified under EPA WaterSense, Symmons 0195-2W--1.5 tests at 1.5 gpm (#559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads), trimming 40.0% off the 2.5 gpm federal cap while cutting 3-person household draw by ~17,520 gal/yr versus 3.5 gpm fixtures. Compare EPA WaterSense certified flow metrics for Symmons 0195-2W--1.5 WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.5 gpm
- vs. EPAct 1992
- -40.0% (2.5 gpm)
- Annual Draw (1 Pers.)
- 4,380 gal/yr
- Annual Saved vs. Legacy
- 5,840 gal/person
- Brand EPA Count
- 511 showerheads
- Series / Variants
- 0195-2W--1.5 (2)

What does Symmons 0195-2W--1.5 Benchmark & Water Budget show?
Efficiency check: certified at 1.5 gpm, Symmons 0195-2W--1.5 (1 Mode Hand Shower Wand) trims 40.0% under federal 2.5 gpm caps; #559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads (0.25 gpm lower-flow than the 1.75 gpm median).
Verify >=30 PSI static water pressure and pair this 1.5 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.
Brand breadth: Symmons holds 511 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~17,520 gallons/yr—roughly $140/yr in low-tariff towns ($8/1k gal), $193/yr at national averages ($11/1k gal), or $315/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: Acorn Controls CSH-WSC (1.5 gpm) and ACORN CSH-WSA (1.5 gpm).
Where does Symmons 0195-2W--1.5 sit on the EPA WaterSense showerhead flow curve?
Comparing Symmons 0195-2W--1.5 (1.50 gpm) against federal EPAct (2.5 gpm) and legacy (3.5 gpm) baselines shows immediate per-use conservation.
How do subfloor levelness and rough-in height protect Symmons 0195-2W--1.5?
Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.
What official WaterSense figures verify Symmons 0195-2W--1.5?
Examine Symmons 0195-2W--1.5 certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Symmons (511 certified) | EPA WaterSense Partner |
| Model Number / Series | 0195-2W--1.5 | 1 Mode Hand Shower Wand (2 finish variants) |
| Rated Consumption | 1.5 gpm | Category median 1.75 gpm (n=18,544 rated) |
| Shower / Faucet Pairing | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |
Which 2 finish and trim SKUs share the Symmons 0195-2W--1.5 WaterSense spec?
Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 2 representative EPA SKU variations are consolidated below.
| Certified Finish SKU | Verified Flow | Series Designation |
|---|---|---|
| 0195-2W-*-1.5 | 1.5 gpm | 1 Mode Hand Shower Wand |
| EF-100-*-1.5 | 1.5 gpm | 1 Mode Hand Shower Wand |
What annual utility savings does Symmons 0195-2W--1.5 deliver?
Compare 1-to-4-person household water use with Symmons 0195-2W--1.5 against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 4,380 gal | 2,920 gal | 5,840 gal (~$64) |
| 2 Occupants | 8,760 gal | 5,840 gal | 11,680 gal (~$128) |
| 3 Occupants | 13,140 gal | 8,760 gal | 17,520 gal (~$140–$315) |
| 4 Occupants | 17,520 gal | 11,680 gal | 23,360 gal (~$257) |
What alternative WaterSense models compare to Symmons 0195-2W--1.5?
Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.
| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| Acorn Controls CSH-WSC | 1.5 gpm (Same flow) | WaterSense |
| ACORN CSH-WSA | 1.5 gpm (Same flow) | WaterSense |
| Aquacubic ASH8469 | 1.5 gpm (Same flow) | WaterSense |
| California Faucet SH-04T.15 | 1.5 gpm (Same flow) | WaterSense |
| Chi Liu CL-01627-2 | 1.5 gpm (Same flow) | WaterSense |
What will Symmons 0195-2W--1.5 save on your annual water bill?
Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.
When does Symmons 0195-2W--1.5 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Symmons 0195-2W--1.5.
Limitations & Who Should Skip
- Existing shower valve lacks ASSE 1016 pressure balancing
Best-Fit Homeowner Profiles
- Recommended when: Meeting 2.5 gpm federal & stricter WaterSense caps
- Target scenario: Targeting ~$193/yr utility savings (3-person home)
Which homeowner questions come up most for Symmons 0195-2W--1.5?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Symmons 0195-2W--1.5.
What annual gallon reduction does Symmons 0195-2W--1.5 achieve over older plumbing?
Testing at 1.5 gpm, Symmons 0195-2W--1.5 uses 62.5% less water than 4.0 gpm pre-1994 models (40.0% below 2.5 gpm EPAct), conserving 7,300 gallons per resident each year.
When can Symmons 0195-2W--1.5 (1.5 gpm) underperform in an older bathroom?
Skip Symmons 0195-2W--1.5 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.
How do 133 WaterSense rebate programs treat Symmons 0195-2W--1.5?
Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Symmons 0195-2W--1.5, itemized purchase invoices, and residential installation addresses.
How does Symmons 0195-2W--1.5 perform relative to the EPA WaterSense category median?
Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.5 gpm, Symmons 0195-2W--1.5 sits below the category median while clearing federal WaterSense caps.
How much does a 3-resident family save yearly switching to Symmons 0195-2W--1.5?
At $11 per 1,000 gallons, a 3-person household conserving 21,900 gallons/yr with Symmons 0195-2W--1.5 trims roughly $241 annually off water and sewer utility bills.
What anti-scald valve standard pairs with Symmons 0195-2W--1.5?
Pairing Symmons 0195-2W--1.5 (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.
How is EPA WaterSense performance tested beyond raw gpm flow caps?
EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.
Does installing Symmons 0195-2W--1.5 require a municipal plumbing permit?
Like-for-like swaps using Symmons 0195-2W--1.5 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)