Skip to main content
Grant Estimator

ZURN Z7000-S5-VP-1.25 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · ZURN (1 SKU)
Verified Specification Summary

Operating at 1.25 gpm, the ZURN Z7000-S5-VP-1.25 showerhead beats 1992 EPAct rules (2.5 gpm) by 50.0% (#56 of 18,544 certified showerheads; most water-efficient 3.0% of 18,544 certified showerheads, lower-flow than 97.0% of certified showerheads), saving a 3-resident home ~19,710 gallons annually compared to 3.5 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for ZURN Z7000-S5-VP-1.25 WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.25 gpm
vs. EPAct 1992
-50.0% (2.5 gpm)
Annual Draw (1 Pers.)
3,650 gal/yr
Annual Saved vs. Legacy
6,570 gal/person
Brand EPA Count
4 showerheads
Series / Variants
Z7000-S5-VP-1.25 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does ZURN Z7000-S5-VP-1.25 Benchmark & Water Budget show?

WaterSense benchmark: ZURN series Z7000-S5-VP-1.25 verifies 1.25 gpm delivery, scoring 50.0% leaner than EPAct 1992 (2.5 gpm) at #56 of 18,544 certified showerheads; most water-efficient 3.0% of 18,544 certified showerheads, lower-flow than 97.0% of certified showerheads (0.50 gpm lower-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.25 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: ZURN holds 4 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~19,710 gallons/yr—roughly $158/yr in low-tariff towns ($8/1k gal), $217/yr at national averages ($11/1k gal), or $355/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: ECO-LOGICAL B125-CH (1.25 gpm) and ECO-LOGICAL B125-W (1.25 gpm).

How much leaner is ZURN Z7000-S5-VP-1.25 than pre-1994 3.5 gpm plumbing?

Flow distribution bars contrast ZURN Z7000-S5-VP-1.25 (1.25 gpm) directly with the 1.75 gpm WaterSense median and 3.5 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): Z7000-S5-VP-1.25: 1.25; EPA Max Cap: 2.00; EPAct 1992: 2.50; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Z7000-S5-VP-1.25: 1.25Z7000-S5-VP-1.251.25EPA Max Cap: 2.00EPA Max Cap2.00EPAct 1992: 2.50EPAct 19922.50Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Showerhead)Histogram of 18544 items for Registry Flow Distribution (Showerhead). Min 1 gpm, median 1.75 gpm, max 2 gpm. Marker 1.25 gpm: 1.25 gpm (3rd percentile).Registry Flow Distribution (Showerhead)n=18544 · median 1.75 gpm0320964181 gpm to 1.1 gpm: 521.1 gpm to 1.2 gpm: 31.2 gpm to 1.3 gpm: 5001.3 gpm to 1.4 gpm: 31.4 gpm to 1.5 gpm: 01.5 gpm to 1.6 gpm: 27891.6 gpm to 1.7 gpm: 751.7 gpm to 1.8 gpm: 64181.8 gpm to 1.9 gpm: 51411.9 gpm to 2 gpm: 35631 gpm1.5 gpm2 gpm1.25 gpm: 1.25 gpm (P3)

Which framing and flange tolerances matter before installing ZURN Z7000-S5-VP-1.25?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does ZURN Z7000-S5-VP-1.25 compare to WaterSense category caps?

Each specification row below documents ZURN Z7000-S5-VP-1.25 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share ZURN (4 certified) EPA WaterSense Partner
Model Number / Series Z7000-S5-VP-1.25 Certified Series (1 finish variants)
Rated Consumption 1.25 gpm Category median 1.75 gpm (n=18,544 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does ZURN Z7000-S5-VP-1.25 cut?

Calculated annual water budgets below quantify ZURN Z7000-S5-VP-1.25 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for ZURN Z7000-S5-VP-1.25 (1.25 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant3,650 gal3,650 gal6,570 gal (~$72)
2 Occupants7,300 gal7,300 gal13,140 gal (~$145)
3 Occupants10,950 gal10,950 gal19,710 gal (~$158–$355)
4 Occupants14,600 gal14,600 gal26,280 gal (~$289)

Which competing models share ZURN Z7000-S5-VP-1.25 flow tier?

Review five peer WaterSense units matching ZURN Z7000-S5-VP-1.25 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer showerhead models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
ECO-LOGICAL B125-CH 1.25 gpm (Same flow) Showerhead
ECO-LOGICAL B125-W 1.25 gpm (Same flow) Showerhead
EVOLVE/AM EV3019-BN125-FB 1.25 gpm (Same flow) Showerhead
EVOLVE/AM EV3019-CP125-FB 1.25 gpm (Same flow) Showerhead
EVOLVE/AM EV3019-MB125-FB 1.25 gpm (Same flow) Showerhead

Can you estimate ZURN Z7000-S5-VP-1.25 payback in your home?

Test how many gallons and dollars ZURN Z7000-S5-VP-1.25 saves each year by entering your household residents and local water-sewer rate below.

Who should not install ZURN Z7000-S5-VP-1.25 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting ZURN Z7000-S5-VP-1.25 for residential use.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Ideal fit: Upgrading 3.5 gpm fixtures for 64.3% water reduction
  • Primary match: Matching ZURN SKU Z7000-S5-VP-1.25 certification on rebate forms

How do federal and code standards apply to ZURN Z7000-S5-VP-1.25?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for ZURN Z7000-S5-VP-1.25.

How much water does ZURN Z7000-S5-VP-1.25 save compared with EPAct 1992 and pre-1994 fixtures?

Rated at 1.25 gpm, ZURN Z7000-S5-VP-1.25 cuts 50.0% below the 2.5 gpm EPAct 1992 ceiling and 68.8% under 4.0 gpm legacy units, saving 8,030 gal/person/yr (3,650 vs EPAct).

Who should NOT install ZURN Z7000-S5-VP-1.25 without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.25 gpm showerhead.

Can homeowners claim utility rebates when installing ZURN Z7000-S5-VP-1.25?

Because ZURN Z7000-S5-VP-1.25 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is ZURN Z7000-S5-VP-1.25 leaner than typical WaterSense showerhead models?

Compared with the 1.8 gpm WaterSense showerhead median, ZURN Z7000-S5-VP-1.25's 1.25 gpm rating places it below category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with ZURN Z7000-S5-VP-1.25?

Upgrading a 4.0 gpm legacy fixture to ZURN Z7000-S5-VP-1.25 saves ~24,090 gallons yearly for three occupants, about $265/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with ZURN Z7000-S5-VP-1.25?

Pairing ZURN Z7000-S5-VP-1.25 (1.25 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.25 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing ZURN Z7000-S5-VP-1.25 require a municipal plumbing permit?

Like-for-like swaps using ZURN Z7000-S5-VP-1.25 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories