Skip to main content
Grant Estimator

American Standard 2548A100 WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · STUDIO S (1 SKU)
Verified Specification Summary

Verified by EPA WaterSense at 1.0 gpf, American Standard 2548A100 sits 37.5% under federal 1.6 gpf ceilings (#165 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 12.8% of 3,875 rated single-flush models, lower-flow than 87.2% of rated single-flush models) and saves ~13,689 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for American Standard 2548A100 WaterSense Toilet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpf
vs. EPAct 1992
-37.5% (1.6 gpf)
Annual Draw (1 Pers.)
1,825 gal/yr
Annual Saved vs. Legacy
4,563 gal/person
Brand EPA Count
403 toilets
Series / Variants
2548A100 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does American Standard 2548A100 Benchmark & Water Budget show?

Under EPA WaterSense protocols, American Standard 2548A100 (STUDIO S) delivers 1.0 gpf (#165 of 3,875 rated single-flush models; most water-efficient 12.8% of 3,875 rated single-flush models, lower-flow than 87.2% of rated single-flush models (0.28 gpf lower-flow than the 1.28 gpf median)), beating the 1.6 gpf federal ceiling by 37.5%.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.0 gpf bowl (Pressure Assist flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: American Standard holds 403 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~13,689 gallons/yr—roughly $110/yr in low-tariff towns ($8/1k gal), $151/yr at national averages ($11/1k gal), or $246/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: Abath KBF-TPT001 (1.0 gpf) and AXENT R60-E (1.0 gpf).

Where does American Standard 2548A100 rank among 6,793 certified toilets?

Review how American Standard 2548A100 (1.00 gpf) places inside EPA WaterSense's 6,793-SKU toilet registry alongside historical 3.5 gpf units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): 2548A100: 1.00; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)2548A100: 1.002548A1001.00EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.0 gpf: 1 gpf (13th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.0 gpf: 1 gpf (P13)

What plumbing rough-in clearances prevent leaks around American Standard 2548A100?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which certified attributes define American Standard 2548A100 performance?

Official U.S. EPA WaterSense registry entries below confirm American Standard 2548A100 rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share American Standard (403 certified) EPA WaterSense Partner
Model Number / Series 2548A100 STUDIO S (1 finish variants)
Rated Consumption 1.0 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Pressure Assist Verify rough-in & supply pressure

How do American Standard 2548A100 savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to American Standard 2548A100 across different household sizes.

Computed annual water savings for American Standard 2548A100 (1.0 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,825 gal1,095 gal4,563 gal (~$50)
2 Occupants3,650 gal2,190 gal9,126 gal (~$100)
3 Occupants5,475 gal3,285 gal13,689 gal (~$110–$246)
4 Occupants7,300 gal4,380 gal18,252 gal (~$201)

Which peer fixtures deliver flow close to American Standard 2548A100?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
Abath KBF-TPT001 1.0 gpf (Same flow) Single / Gravity
AXENT R60-E 1.0 gpf (Same flow) Single / Pressure Assist
Axent W376-123X-U1 1.0 gpf (Same flow) Single / Gravity
Bolina W8273+T8272 1.0 gpf (Same flow) Single / Gravity
Cabalo CZ59E16S22338 1.0 gpf (Same flow) Single / Gravity

Does American Standard 2548A100 pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark American Standard 2548A100 annual savings immediately.

What plumbing or duct constraints rule out American Standard 2548A100?

Compare where American Standard 2548A100 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Unvented branch drain causing slow bowl clear

Best-Fit Homeowner Profiles

  • Homeowner profile: Upgrading 3.5 gpf fixtures for 71.4% water reduction
  • Suited to: Matching American Standard SKU 2548A100 certification on rebate forms

Where do official rules set limits for American Standard 2548A100?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing American Standard 2548A100.

How does American Standard 2548A100 perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.0 gpf, American Standard 2548A100 sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to American Standard 2548A100?

At $11 per 1,000 gallons, a 3-person household conserving 13,686 gallons/yr with American Standard 2548A100 trims roughly $151 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to American Standard 2548A100?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.0 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing American Standard 2548A100 require a municipal plumbing permit?

Like-for-like swaps using American Standard 2548A100 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 3.5 gpf fixture to American Standard 2548A100 at 1.0 gpf?

Swapping a 3.5 gpf unit for American Standard 2548A100 slashes water draw 71.4% (4,562 gal/person/yr), beating 1.6 gpf federal EPAct standards by 37.5%.

When does switching to American Standard 2548A100 (1.0 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.0 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

How do 133 WaterSense rebate programs treat American Standard 2548A100?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like American Standard 2548A100, itemized purchase invoices, and residential installation addresses.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories