Homeowners upgrading older 3.5 gpf plumbing to American Standard 288CA114 (1.1 gpf, #530 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 14.9% of 3,875 rated single-flush models, lower-flow than 85.1% of rated single-flush models) cut 68.6% off legacy draw, conserving ~13,140 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for American Standard 288CA114 WaterSense Toilet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.1 gpf
- vs. EPAct 1992
- -31.2% (1.6 gpf)
- Annual Draw (1 Pers.)
- 2,008 gal/yr
- Annual Saved vs. Legacy
- 4,380 gal/person
- Brand EPA Count
- 403 toilets
- Series / Variants
- 288CA114 (1)

What does American Standard 288CA114 Benchmark & Water Budget show?
Laboratory testing places American Standard 288CA114 (H2Optimum UHET SF NHEL) at 1.1 gpf (ultra-low sub-1.1 gpf tier), saving 31.2% vs. EPAct 1992 (1.6 gpf) while ranking #530 of 3,875 rated single-flush models; most water-efficient 14.9% of 3,875 rated single-flush models, lower-flow than 85.1% of rated single-flush models (0.18 gpf lower-flow than the 1.28 gpf median). Bowl 3706216.XXX / Tank 4133A.114.XXX.
For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.1 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.
Brand breadth: American Standard holds 403 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~13,140 gallons/yr—roughly $105/yr in low-tariff towns ($8/1k gal), $145/yr at national averages ($11/1k gal), or $237/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: Axent AT5560-XX/AT5561 (1.1 gpf) and Axent AT5570-XX/AT5561 (1.1 gpf).
How do federal gpf limits contrast with American Standard 288CA114 tested flow?
Each bar isolates American Standard 288CA114 (1.10 gpf) relative to the EPA cap, federal EPAct 1992 standard (1.6 gpf), and pre-1994 draw.
How does wet-zone tile prep interact with American Standard 288CA114 rough-ins?
Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.
What plumbing standards accompany American Standard 288CA114 installation?
Verify American Standard 288CA114 EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | American Standard (403 certified) | EPA WaterSense Partner |
| Model Number / Series | 288CA114 | H2Optimum UHET SF NHEL (1 finish variants) |
| Rated Consumption | 1.1 gpf | Category median 1.28 gpf (n=3,875 rated) |
| Flush / Valve Architecture | Single / Gravity | Verify rough-in & supply pressure |
What household water budget fits American Standard 288CA114?
Annual consumption rows below translate American Standard 288CA114 certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 2,008 gal | 912 gal | 4,380 gal (~$48) |
| 2 Occupants | 4,016 gal | 1,824 gal | 8,760 gal (~$96) |
| 3 Occupants | 6,024 gal | 2,736 gal | 13,140 gal (~$105–$237) |
| 4 Occupants | 8,032 gal | 3,648 gal | 17,520 gal (~$193) |
Where can buyers find alternatives to American Standard 288CA114?
Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.
| Peer Brand & Model | Rated GPF (Delta) | Flush / Model Detail |
|---|---|---|
| Axent AT5560-XX/AT5561 | 1.1 gpf (Same flow) | Single / Pressure Assist |
| Axent AT5570-XX/AT5561 | 1.1 gpf (Same flow) | Single / Pressure Assist |
| Axent Z814-2020 | 1.1 gpf (Same flow) | Single / Pressure Assist |
| CATO J0001XXXXXX | 1.1 gpf (Same flow) | Single / Gravity |
| Gerber GEF21312 | 1.1 gpf (Same flow) | Single / Pressure Assist |
What annual bill drop does American Standard 288CA114 achieve for your family?
Calculate annual gallons conserved and dollar savings for American Standard 288CA114 using your exact occupant count and utility tariff without submitting personal info.
When does American Standard 288CA114 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering American Standard 288CA114.
Limitations & Who Should Skip
- Building drain lacks 1/4 in/ft slope for reduced flush carry
Best-Fit Homeowner Profiles
- Recommended when: Meeting 1.6 gpf federal & stricter WaterSense caps
- Target scenario: Targeting ~$145/yr utility savings (3-person home)
Which code checks and cost facts matter for American Standard 288CA114?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to American Standard 288CA114.
How do 133 WaterSense rebate programs treat American Standard 288CA114?
Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like American Standard 288CA114, itemized purchase invoices, and residential installation addresses.
How does American Standard 288CA114 perform relative to the EPA WaterSense category median?
Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.1 gpf, American Standard 288CA114 sits below the category median while clearing federal WaterSense caps.
How much does a 3-resident family save yearly switching to American Standard 288CA114?
At $11 per 1,000 gallons, a 3-person household conserving 13,140 gallons/yr with American Standard 288CA114 trims roughly $145 annually off water and sewer utility bills.
What closet flange and side-wall clearances apply to American Standard 288CA114?
IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).
How is EPA WaterSense performance tested beyond raw gpf flow caps?
EPA WaterSense certification pairs the 1.1 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.
Does installing American Standard 288CA114 require a municipal plumbing permit?
Like-for-like swaps using American Standard 288CA114 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
What annual gallon reduction does American Standard 288CA114 achieve over older plumbing?
Testing at 1.1 gpf, American Standard 288CA114 uses 68.6% less water than 3.5 gpf pre-1994 models (31.2% below 1.6 gpf EPAct), conserving 4,380 gallons per resident each year.
When does switching to American Standard 288CA114 (1.1 gpf) require a drain inspection?
Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.1 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)