Operating at 1.28 gpf, the CANTON 803-6392+803-6393 toilet beats 1992 EPAct rules (1.6 gpf) by 20.0% (#595 of 3,875 rated single-flush models (out of 6,793 certified toilets); tied with 3,280 other rated single-flush models at the 1.28 gpf median), saving a 3-resident home ~12,156 gallons annually compared to 3.5 gpf legacy hardware. Compare EPA WaterSense certified flow metrics for CANTON 803-6392+803-6393 WaterSense Toilet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.28 gpf
- vs. EPAct 1992
- -20.0% (1.6 gpf)
- Annual Draw (1 Pers.)
- 2,336 gal/yr
- Annual Saved vs. Legacy
- 4,052 gal/person
- Brand EPA Count
- 40 toilets
- Series / Variants
- 803-6392+803-6393 (1)

What does CANTON 803-6392+803-6393 Benchmark & Water Budget show?
WaterSense benchmark: CANTON series 803-6392+803-6393 verifies 1.28 gpf delivery, scoring 20.0% leaner than EPAct 1992 (1.6 gpf) at #595 of 3,875 rated single-flush models; tied with 3,280 other rated single-flush models at the 1.28 gpf median.
For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.28 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.
Brand breadth: CANTON holds 40 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~12,156 gallons/yr—roughly $97/yr in low-tariff towns ($8/1k gal), $134/yr at national averages ($11/1k gal), or $219/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Fairfield (CA) list active rebates among 200 U.S. programs. Closest alternatives: AIMLER W.C - AC-039 / TANK - AC-040 (1.28 gpf) and American Standard 2568128 (1.28 gpf).
How much leaner is CANTON 803-6392+803-6393 than pre-1994 3.5 gpf plumbing?
Flow distribution bars contrast CANTON 803-6392+803-6393 (1.28 gpf) directly with the 1.28 gpf WaterSense median and 3.5 gpf older fixtures.
Which framing and flange tolerances matter before installing CANTON 803-6392+803-6393?
Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.
How does CANTON 803-6392+803-6393 compare to WaterSense category caps?
Each specification row below documents CANTON 803-6392+803-6393 tested consumption against national EPA category medians and EPAct 1992 federal baselines.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | CANTON (40 certified) | EPA WaterSense Partner |
| Model Number / Series | 803-6392+803-6393 | Certified Series (1 finish variants) |
| Rated Consumption | 1.28 gpf | Category median 1.28 gpf (n=3,875 rated) |
| Flush / Valve Architecture | Single / Gravity | Verify rough-in & supply pressure |
How many gallons per year does CANTON 803-6392+803-6393 cut?
Calculated annual water budgets below quantify CANTON 803-6392+803-6393 savings per occupant and estimated combined water-sewer bill reductions across household sizes.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 2,336 gal | 584 gal | 4,052 gal (~$45) |
| 2 Occupants | 4,672 gal | 1,168 gal | 8,104 gal (~$89) |
| 3 Occupants | 7,008 gal | 1,752 gal | 12,156 gal (~$97–$219) |
| 4 Occupants | 9,344 gal | 2,336 gal | 16,208 gal (~$178) |
Which competing models share CANTON 803-6392+803-6393 flow tier?
Review five peer WaterSense units matching CANTON 803-6392+803-6393 conservation range so homeowners can verify contractor fixture swaps on written bids.
| Peer Brand & Model | Rated GPF (Delta) | Flush / Model Detail |
|---|---|---|
| AIMLER W.C - AC-039 / TANK... | 1.28 gpf (Same flow) | Single / Gravity |
| American Standard 2568128 | 1.28 gpf (Same flow) | Single / Gravity |
| American Standard 3332128DISP | 1.28 gpf (Same flow) | Single / Gravity |
| Aquasource 810485/T802M | 1.28 gpf (Same flow) | Single / Gravity |
| Bathroom Anywhere 42832 | 1.28 gpf (Same flow) | Single / Gravity |
Can you estimate CANTON 803-6392+803-6393 payback in your home?
Test how many gallons and dollars CANTON 803-6392+803-6393 saves each year by entering your household residents and local water-sewer rate below.
Does CANTON 803-6392+803-6393 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying CANTON 803-6392+803-6393 for your remodel.
Limitations & Who Should Skip
- Unvented branch drain causing slow bowl clear
Best-Fit Homeowner Profiles
- Strong scenario: Upgrading 3.5 gpf fixtures for 63.4% water reduction
- Best application: Matching CANTON SKU 803-6392+803-6393 certification on rebate forms
How do federal and code standards apply to CANTON 803-6392+803-6393?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for CANTON 803-6392+803-6393.
Does CANTON 803-6392+803-6393 qualify for municipal utility water rebates in 2026?
Yes, EPA WaterSense certification makes CANTON 803-6392+803-6393 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.
Where does CANTON 803-6392+803-6393 rank against other certified toilets?
Rated at 1.28 gpf, CANTON 803-6392+803-6393 measures equal to the 1.28 gpf WaterSense toilet median across thousands of EPA-listed residential fixtures.
Does CANTON 803-6392+803-6393 cut utility costs noticeably for a 3-person household?
Yes: cutting 12,153 gallons/yr relative to 3.5 gpf hardware translates to ~$134/yr in combined water/sewer savings at $11/1k gal.
What closet flange and side-wall clearances apply to CANTON 803-6392+803-6393?
IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).
How is EPA WaterSense performance tested beyond raw gpf flow caps?
EPA WaterSense certification pairs the 1.28 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.
Does installing CANTON 803-6392+803-6393 require a municipal plumbing permit?
Like-for-like swaps using CANTON 803-6392+803-6393 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
What efficiency edge separates CANTON 803-6392+803-6393 from legacy and EPAct models?
Certified at 1.28 gpf, CANTON 803-6392+803-6393 achieves 20.0% savings against EPAct 1992 (1.6 gpf) and 63.4% savings against 3.5 gpf fixtures, 4,051 gallons per occupant yearly.
Are older sewer lines safe for CANTON 803-6392+803-6393's 1.28 gpf flush volume?
Most copper/PVC lines handle 1.28 gpf cleanly, whereas sagging or scaled cast-iron laterals lacking 1/4 in/ft slope should be scoped prior to replacing 3.5 gpf bowls.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)