Skip to main content
Grant Estimator

Contrac 4710BSXU WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Wilton (1 SKU)
Verified Specification Summary

Verified by EPA WaterSense at 0.8 gpf, Contrac 4710BSXU sits 50.0% under federal 1.6 gpf ceilings (#4 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 3.2% of 3,875 rated single-flush models, lower-flow than 96.8% of rated single-flush models) and saves ~14,784 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for Contrac 4710BSXU WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
0.8 gpf
vs. EPAct 1992
-50.0% (1.6 gpf)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
4,928 gal/person
Brand EPA Count
116 toilets
Series / Variants
4710BSXU (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Contrac 4710BSXU Benchmark & Water Budget show?

Under EPA WaterSense protocols, Contrac 4710BSXU (Wilton) delivers 0.8 gpf (#4 of 3,875 rated single-flush models; most water-efficient 3.2% of 3,875 rated single-flush models, lower-flow than 96.8% of rated single-flush models (0.48 gpf lower-flow than the 1.28 gpf median)), beating the 1.6 gpf federal ceiling by 50.0%.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 0.8 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Contrac holds 116 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~14,784 gallons/yr—roughly $118/yr in low-tariff towns ($8/1k gal), $163/yr at national averages ($11/1k gal), or $266/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: Aflush/Waso A2001EP (0.8 gpf) and American Standard 250AA808 (0.8 gpf).

Where does Contrac 4710BSXU rank among 6,793 certified toilets?

Review how Contrac 4710BSXU (0.80 gpf) places inside EPA WaterSense's 6,793-SKU toilet registry alongside historical 3.5 gpf units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): 4710BSXU: 0.80; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)4710BSXU: 0.804710BSXU0.80EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 0.8 gpf: 0.8 gpf (3rd percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf0.8 gpf: 0.8 gpf (P3)

What plumbing rough-in clearances prevent leaks around Contrac 4710BSXU?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which certified attributes define Contrac 4710BSXU performance?

Official U.S. EPA WaterSense registry entries below confirm Contrac 4710BSXU rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Contrac (116 certified) EPA WaterSense Partner
Model Number / Series 4710BSXU Wilton (1 finish variants)
Rated Consumption 0.8 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

How do Contrac 4710BSXU savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to Contrac 4710BSXU across different household sizes.

Computed annual water savings for Contrac 4710BSXU (0.8 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,460 gal4,928 gal (~$54)
2 Occupants2,920 gal2,920 gal9,856 gal (~$108)
3 Occupants4,380 gal4,380 gal14,784 gal (~$118–$266)
4 Occupants5,840 gal5,840 gal19,712 gal (~$217)

Which peer fixtures deliver flow close to Contrac 4710BSXU?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
Aflush/Waso A2001EP 0.8 gpf (Same flow) Single / Gravity
American Standard 250AA808 0.8 gpf (Same flow) Single / Gravity
American Standard 250AA809 0.8 gpf (Same flow) Single / Gravity
American Standard 251AA808 0.8 gpf (Same flow) Single / Gravity
American Standard 251AA809 0.8 gpf (Same flow) Single / Gravity

Does Contrac 4710BSXU pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark Contrac 4710BSXU annual savings immediately.

What plumbing or duct constraints rule out Contrac 4710BSXU?

Compare where Contrac 4710BSXU excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Unvented branch drain causing slow bowl clear

Best-Fit Homeowner Profiles

  • Homeowner profile: Upgrading 3.5 gpf fixtures for 77.1% water reduction
  • Suited to: Matching Contrac SKU 4710BSXU certification on rebate forms

Where do official rules set limits for Contrac 4710BSXU?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Contrac 4710BSXU.

When does switching to Contrac 4710BSXU (0.8 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 0.8 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

How do 133 WaterSense rebate programs treat Contrac 4710BSXU?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Contrac 4710BSXU, itemized purchase invoices, and residential installation addresses.

How does Contrac 4710BSXU perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 0.8 gpf, Contrac 4710BSXU sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Contrac 4710BSXU?

At $11 per 1,000 gallons, a 3-person household conserving 14,784 gallons/yr with Contrac 4710BSXU trims roughly $163 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to Contrac 4710BSXU?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 0.8 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Contrac 4710BSXU require a municipal plumbing permit?

Like-for-like swaps using Contrac 4710BSXU on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 3.5 gpf fixture to Contrac 4710BSXU at 0.8 gpf?

Swapping a 3.5 gpf unit for Contrac 4710BSXU slashes water draw 77.1% (4,928 gal/person/yr), beating 1.6 gpf federal EPAct standards by 50.0%.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories