DXV D22010C.101-xxx WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Roycroft (1 SKU)
Verified Specification Summary

Certified under EPA WaterSense, DXV D22010C.101-xxx tests at 1.28 gpf (#595 of 3,875 rated single-flush models (out of 6,793 certified toilets); tied with 3,280 other rated single-flush models at the 1.28 gpf median), trimming 20.0% off the 1.6 gpf federal cap while cutting 3-person household draw by ~12,156 gal/yr versus 3.5 gpf fixtures. Compare EPA WaterSense certified flow metrics for DXV D22010C.101-xxx WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.28 gpf
vs. EPAct 1992
-20.0% (1.6 gpf)
Annual Draw (1 Pers.)
2,336 gal/yr
Annual Saved vs. Legacy
4,052 gal/person
Brand EPA Count
26 toilets
Series / Variants
D22010C.101-xxx (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does DXV D22010C.101-xxx Benchmark & Water Budget show?

Efficiency check: certified at 1.28 gpf, DXV D22010C.101-xxx (Roycroft) trims 20.0% under federal 1.6 gpf caps; #595 of 3,875 rated single-flush models; tied with 3,280 other rated single-flush models at the 1.28 gpf median.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.28 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: DXV holds 26 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~12,156 gallons/yr—roughly $97/yr in low-tariff towns ($8/1k gal), $134/yr at national averages ($11/1k gal), or $219/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: AIMLER W.C - AC-039 / TANK - AC-040 (1.28 gpf) and American Standard 2568128 (1.28 gpf).

Where does DXV D22010C.101-xxx sit on the EPA WaterSense toilet flow curve?

Comparing DXV D22010C.101-xxx (1.28 gpf) against federal EPAct (1.6 gpf) and legacy (3.5 gpf) baselines shows immediate per-use conservation.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): D22010C.101-xxx: 1.28; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)D22010C.101-xxx: 1.28D22010C.101-xxx1.28EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.28 gpf: 1.28 gpf (100th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.28 gpf: 1.28 gpf (P100)

How do subfloor levelness and rough-in height protect DXV D22010C.101-xxx?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What official WaterSense figures verify DXV D22010C.101-xxx?

Examine DXV D22010C.101-xxx certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share DXV (26 certified) EPA WaterSense Partner
Model Number / Series D22010C.101-xxx Roycroft (1 finish variants)
Rated Consumption 1.28 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

What annual utility savings does DXV D22010C.101-xxx deliver?

Compare 1-to-4-person household water use with DXV D22010C.101-xxx against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for DXV D22010C.101-xxx (1.28 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,336 gal584 gal4,052 gal (~$45)
2 Occupants4,672 gal1,168 gal8,104 gal (~$89)
3 Occupants7,008 gal1,752 gal12,156 gal (~$97–$219)
4 Occupants9,344 gal2,336 gal16,208 gal (~$178)

What alternative WaterSense models compare to DXV D22010C.101-xxx?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
AIMLER W.C - AC-039 / TANK... 1.28 gpf (Same flow) Single / Gravity
American Standard 2568128 1.28 gpf (Same flow) Single / Gravity
American Standard 3332128DISP 1.28 gpf (Same flow) Single / Gravity
Aquasource 810485/T802M 1.28 gpf (Same flow) Single / Gravity
Bathroom Anywhere 42832 1.28 gpf (Same flow) Single / Gravity

What will DXV D22010C.101-xxx save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

When does DXV D22010C.101-xxx fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering DXV D22010C.101-xxx.

Limitations & Who Should Skip

  • Building drain lacks 1/4 in/ft slope for reduced flush carry

Best-Fit Homeowner Profiles

  • Recommended when: Meeting 1.6 gpf federal & stricter WaterSense caps
  • Target scenario: Targeting ~$134/yr utility savings (3-person home)

Which homeowner questions come up most for DXV D22010C.101-xxx?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around DXV D22010C.101-xxx.

How do 133 WaterSense rebate programs treat DXV D22010C.101-xxx?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like DXV D22010C.101-xxx, itemized purchase invoices, and residential installation addresses.

How does DXV D22010C.101-xxx perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.28 gpf, DXV D22010C.101-xxx sits equal to the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to DXV D22010C.101-xxx?

At $11 per 1,000 gallons, a 3-person household conserving 12,153 gallons/yr with DXV D22010C.101-xxx trims roughly $134 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to DXV D22010C.101-xxx?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.28 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing DXV D22010C.101-xxx require a municipal plumbing permit?

Like-for-like swaps using DXV D22010C.101-xxx on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does DXV D22010C.101-xxx achieve over older plumbing?

Testing at 1.28 gpf, DXV D22010C.101-xxx uses 63.4% less water than 3.5 gpf pre-1994 models (20.0% below 1.6 gpf EPAct), conserving 4,051 gallons per resident each year.

When does switching to DXV D22010C.101-xxx (1.28 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.28 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories