Skip to main content
Grant Estimator

Icera C-2620 WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Vista II (1 SKU)
Verified Specification Summary

Operating at 1.28 gpf, the Icera C-2620 toilet beats 1992 EPAct rules (1.6 gpf) by 20.0% (#595 of 3,875 rated single-flush models (out of 6,793 certified toilets); tied with 3,280 other rated single-flush models at the 1.28 gpf median), saving a 3-resident home ~12,156 gallons annually compared to 3.5 gpf legacy hardware. Compare EPA WaterSense certified flow metrics for Icera C-2620 WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.28 gpf
vs. EPAct 1992
-20.0% (1.6 gpf)
Annual Draw (1 Pers.)
2,336 gal/yr
Annual Saved vs. Legacy
4,052 gal/person
Brand EPA Count
12 toilets
Series / Variants
C-2620 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Icera C-2620 Benchmark & Water Budget show?

WaterSense benchmark: Icera series C-2620 (Vista II) verifies 1.28 gpf delivery, scoring 20.0% leaner than EPAct 1992 (1.6 gpf) at #595 of 3,875 rated single-flush models; tied with 3,280 other rated single-flush models at the 1.28 gpf median.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.28 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Icera holds 12 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~12,156 gallons/yr—roughly $97/yr in low-tariff towns ($8/1k gal), $134/yr at national averages ($11/1k gal), or $219/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: AIMLER W.C - AC-039 / TANK - AC-040 (1.28 gpf) and American Standard 2568128 (1.28 gpf).

How much leaner is Icera C-2620 than pre-1994 3.5 gpf plumbing?

Flow distribution bars contrast Icera C-2620 (1.28 gpf) directly with the 1.28 gpf WaterSense median and 3.5 gpf older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): C-2620: 1.28; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)C-2620: 1.28C-26201.28EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.28 gpf: 1.28 gpf (100th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.28 gpf: 1.28 gpf (P100)

Which framing and flange tolerances matter before installing Icera C-2620?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does Icera C-2620 compare to WaterSense category caps?

Each specification row below documents Icera C-2620 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Icera (12 certified) EPA WaterSense Partner
Model Number / Series C-2620 Vista II (1 finish variants)
Rated Consumption 1.28 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

How many gallons per year does Icera C-2620 cut?

Calculated annual water budgets below quantify Icera C-2620 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for Icera C-2620 (1.28 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,336 gal584 gal4,052 gal (~$45)
2 Occupants4,672 gal1,168 gal8,104 gal (~$89)
3 Occupants7,008 gal1,752 gal12,156 gal (~$97–$219)
4 Occupants9,344 gal2,336 gal16,208 gal (~$178)

Which competing models share Icera C-2620 flow tier?

Review five peer WaterSense units matching Icera C-2620 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
AIMLER W.C - AC-039 / TANK... 1.28 gpf (Same flow) Single / Gravity
American Standard 2568128 1.28 gpf (Same flow) Single / Gravity
American Standard 3332128DISP 1.28 gpf (Same flow) Single / Gravity
Aquasource 810485/T802M 1.28 gpf (Same flow) Single / Gravity
Bathroom Anywhere 42832 1.28 gpf (Same flow) Single / Gravity

Can you estimate Icera C-2620 payback in your home?

Test how many gallons and dollars Icera C-2620 saves each year by entering your household residents and local water-sewer rate below.

When does Icera C-2620 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Icera C-2620.

Limitations & Who Should Skip

  • Unvented branch drain causing slow bowl clear

Best-Fit Homeowner Profiles

  • Recommended when: Upgrading 3.5 gpf fixtures for 63.4% water reduction
  • Target scenario: Matching Icera SKU C-2620 certification on rebate forms

How do federal and code standards apply to Icera C-2620?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Icera C-2620.

How do 133 WaterSense rebate programs treat Icera C-2620?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Icera C-2620, itemized purchase invoices, and residential installation addresses.

How does Icera C-2620 perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.28 gpf, Icera C-2620 sits equal to the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Icera C-2620?

At $11 per 1,000 gallons, a 3-person household conserving 12,153 gallons/yr with Icera C-2620 trims roughly $134 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to Icera C-2620?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.28 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Icera C-2620 require a municipal plumbing permit?

Like-for-like swaps using Icera C-2620 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does Icera C-2620 achieve over older plumbing?

Testing at 1.28 gpf, Icera C-2620 uses 63.4% less water than 3.5 gpf pre-1994 models (20.0% below 1.6 gpf EPAct), conserving 4,051 gallons per resident each year.

When does switching to Icera C-2620 (1.28 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.28 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories