Skip to main content
Grant Estimator

KEORH I6B WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · KEORH (1 SKU)
Verified Specification Summary

Operating at 1.28 gpf, the KEORH I6B toilet beats 1992 EPAct rules (1.6 gpf) by 20.0% (#595 of 3,875 rated single-flush models (out of 6,793 certified toilets); tied with 3,280 other rated single-flush models at the 1.28 gpf median), saving a 3-resident home ~12,156 gallons annually compared to 3.5 gpf legacy hardware. Compare EPA WaterSense certified flow metrics for KEORH I6B WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.28 gpf
vs. EPAct 1992
-20.0% (1.6 gpf)
Annual Draw (1 Pers.)
2,336 gal/yr
Annual Saved vs. Legacy
4,052 gal/person
Brand EPA Count
12 toilets
Series / Variants
I6B (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does KEORH I6B Benchmark & Water Budget show?

WaterSense benchmark: KEORH series I6B verifies 1.28 gpf delivery, scoring 20.0% leaner than EPAct 1992 (1.6 gpf) at #595 of 3,875 rated single-flush models; tied with 3,280 other rated single-flush models at the 1.28 gpf median.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.28 gpf bowl (Pressure Assist flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: KEORH holds 12 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~12,156 gallons/yr—roughly $97/yr in low-tariff towns ($8/1k gal), $134/yr at national averages ($11/1k gal), or $219/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: AIMLER W.C - AC-039 / TANK - AC-040 (1.28 gpf) and American Standard 2568128 (1.28 gpf).

How much leaner is KEORH I6B than pre-1994 3.5 gpf plumbing?

Flow distribution bars contrast KEORH I6B (1.28 gpf) directly with the 1.28 gpf WaterSense median and 3.5 gpf older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): I6B: 1.28; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)I6B: 1.28I6B1.28EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.28 gpf: 1.28 gpf (100th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.28 gpf: 1.28 gpf (P100)

Which framing and flange tolerances matter before installing KEORH I6B?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does KEORH I6B compare to WaterSense category caps?

Each specification row below documents KEORH I6B tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share KEORH (12 certified) EPA WaterSense Partner
Model Number / Series I6B Certified Series (1 finish variants)
Rated Consumption 1.28 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Pressure Assist Verify rough-in & supply pressure

How many gallons per year does KEORH I6B cut?

Calculated annual water budgets below quantify KEORH I6B savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for KEORH I6B (1.28 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,336 gal584 gal4,052 gal (~$45)
2 Occupants4,672 gal1,168 gal8,104 gal (~$89)
3 Occupants7,008 gal1,752 gal12,156 gal (~$97–$219)
4 Occupants9,344 gal2,336 gal16,208 gal (~$178)

Which competing models share KEORH I6B flow tier?

Review five peer WaterSense units matching KEORH I6B conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
AIMLER W.C - AC-039 / TANK... 1.28 gpf (Same flow) Single / Gravity
American Standard 2568128 1.28 gpf (Same flow) Single / Gravity
American Standard 3332128DISP 1.28 gpf (Same flow) Single / Gravity
Aquasource 810485/T802M 1.28 gpf (Same flow) Single / Gravity
Bathroom Anywhere 42832 1.28 gpf (Same flow) Single / Gravity

Can you estimate KEORH I6B payback in your home?

Test how many gallons and dollars KEORH I6B saves each year by entering your household residents and local water-sewer rate below.

Where should contractors skip KEORH I6B on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for KEORH I6B carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Unvented branch drain causing slow bowl clear

Best-Fit Homeowner Profiles

  • Choose this if: Upgrading 3.5 gpf fixtures for 63.4% water reduction
  • Works well for: Matching KEORH SKU I6B certification on rebate forms

How do federal and code standards apply to KEORH I6B?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for KEORH I6B.

How many gallons per person does KEORH I6B save annually?

Each resident saves ~4,051 gallons yearly (63.4% drop) replacing a 3.5 gpf fixture with KEORH I6B (1.28 gpf), or 584 gal/yr versus 1.6 gpf EPAct baselines.

Who should NOT install KEORH I6B without checking house plumbing first?

Homes with aging cast-iron drains, flat slopes under 1/4 in/ft, or pipe bellies should camera-check waste carry before dropping from 3.5 gpf bowls to 1.28 gpf high-efficiency flushing.

Can homeowners claim utility rebates when installing KEORH I6B?

Because KEORH I6B holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is KEORH I6B leaner than typical WaterSense toilet models?

Compared with the 1.28 gpf WaterSense toilet median, KEORH I6B's 1.28 gpf rating places it equal to category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with KEORH I6B?

Upgrading a 3.5 gpf legacy fixture to KEORH I6B saves ~12,153 gallons yearly for three occupants, about $134/yr at $11 per 1,000 gallons combined water and sewer.

What closet flange and side-wall clearances apply to KEORH I6B?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.28 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing KEORH I6B require a municipal plumbing permit?

Like-for-like swaps using KEORH I6B on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories