Homeowners upgrading older 3.5 gpf plumbing to KEORH V12D (1.28 gpf, #595 of 3,875 rated single-flush models (out of 6,793 certified toilets); tied with 3,280 other rated single-flush models at the 1.28 gpf median) cut 63.4% off legacy draw, conserving ~12,156 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for KEORH V12D WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.28 gpf
- vs. EPAct 1992
- -20.0% (1.6 gpf)
- Annual Draw (1 Pers.)
- 2,336 gal/yr
- Annual Saved vs. Legacy
- 4,052 gal/person
- Brand EPA Count
- 12 toilets
- Series / Variants
- V12D (1)

What does KEORH V12D Benchmark & Water Budget show?
Laboratory testing places KEORH V12D at 1.28 gpf (standard 1.28 gpf WaterSense tier), saving 20.0% vs. EPAct 1992 (1.6 gpf) while ranking #595 of 3,875 rated single-flush models; tied with 3,280 other rated single-flush models at the 1.28 gpf median.
For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.28 gpf bowl (Pressure Assist flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.
Brand breadth: KEORH holds 12 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~12,156 gallons/yr—roughly $97/yr in low-tariff towns ($8/1k gal), $134/yr at national averages ($11/1k gal), or $219/yr in high-rate cities ($18/1k gal). Regional utilities such as Liberty Utilities - Arizona (AZ) list active rebates among 200 U.S. programs. Closest alternatives: AIMLER W.C - AC-039 / TANK - AC-040 (1.28 gpf) and American Standard 2568128 (1.28 gpf).
How do federal gpf limits contrast with KEORH V12D tested flow?
Each bar isolates KEORH V12D (1.28 gpf) relative to the EPA cap, federal EPAct 1992 standard (1.6 gpf), and pre-1994 draw.
How does wet-zone tile prep interact with KEORH V12D rough-ins?
Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.
What plumbing standards accompany KEORH V12D installation?
Verify KEORH V12D EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | KEORH (12 certified) | EPA WaterSense Partner |
| Model Number / Series | V12D | Certified Series (1 finish variants) |
| Rated Consumption | 1.28 gpf | Category median 1.28 gpf (n=3,875 rated) |
| Flush / Valve Architecture | Single / Pressure Assist | Verify rough-in & supply pressure |
What household water budget fits KEORH V12D?
Annual consumption rows below translate KEORH V12D certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 2,336 gal | 584 gal | 4,052 gal (~$45) |
| 2 Occupants | 4,672 gal | 1,168 gal | 8,104 gal (~$89) |
| 3 Occupants | 7,008 gal | 1,752 gal | 12,156 gal (~$97–$219) |
| 4 Occupants | 9,344 gal | 2,336 gal | 16,208 gal (~$178) |
Where can buyers find alternatives to KEORH V12D?
Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.
| Peer Brand & Model | Rated GPF (Delta) | Flush / Model Detail |
|---|---|---|
| AIMLER W.C - AC-039 / TANK... | 1.28 gpf (Same flow) | Single / Gravity |
| American Standard 2568128 | 1.28 gpf (Same flow) | Single / Gravity |
| American Standard 3332128DISP | 1.28 gpf (Same flow) | Single / Gravity |
| Aquasource 810485/T802M | 1.28 gpf (Same flow) | Single / Gravity |
| Bathroom Anywhere 42832 | 1.28 gpf (Same flow) | Single / Gravity |
What annual bill drop does KEORH V12D achieve for your family?
Calculate annual gallons conserved and dollar savings for KEORH V12D using your exact occupant count and utility tariff without submitting personal info.
When does KEORH V12D fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering KEORH V12D.
Limitations & Who Should Skip
- Building drain lacks 1/4 in/ft slope for reduced flush carry
Best-Fit Homeowner Profiles
- Recommended when: Meeting 1.6 gpf federal & stricter WaterSense caps
- Target scenario: Targeting ~$134/yr utility savings (3-person home)
Which code checks and cost facts matter for KEORH V12D?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to KEORH V12D.
What annual gallon reduction does KEORH V12D achieve over older plumbing?
Testing at 1.28 gpf, KEORH V12D uses 63.4% less water than 3.5 gpf pre-1994 models (20.0% below 1.6 gpf EPAct), conserving 4,051 gallons per resident each year.
When does switching to KEORH V12D (1.28 gpf) require a drain inspection?
Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.28 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.
How do 133 WaterSense rebate programs treat KEORH V12D?
Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like KEORH V12D, itemized purchase invoices, and residential installation addresses.
How does KEORH V12D perform relative to the EPA WaterSense category median?
Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.28 gpf, KEORH V12D sits equal to the category median while clearing federal WaterSense caps.
How much does a 3-resident family save yearly switching to KEORH V12D?
At $11 per 1,000 gallons, a 3-person household conserving 12,153 gallons/yr with KEORH V12D trims roughly $134 annually off water and sewer utility bills.
What closet flange and side-wall clearances apply to KEORH V12D?
IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).
How is EPA WaterSense performance tested beyond raw gpf flow caps?
EPA WaterSense certification pairs the 1.28 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.
Does installing KEORH V12D require a municipal plumbing permit?
Like-for-like swaps using KEORH V12D on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)