The KEORH V6D is an EPA WaterSense toilet certified at 1.28 gpf, 20.0% below EPAct 1992 (1.6 gpf) and #595 of 3,875 rated single-flush models (out of 6,793 certified toilets); tied with 3,280 other rated single-flush models at the 1.28 gpf median. A 3-person household saves ~12,156 gallons/yr replacing a 3.5 gpf legacy fixture. Compare EPA WaterSense certified flow metrics for KEORH V6D WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.28 gpf
- vs. EPAct 1992
- -20.0% (1.6 gpf)
- Annual Draw (1 Pers.)
- 2,336 gal/yr
- Annual Saved vs. Legacy
- 4,052 gal/person
- Brand EPA Count
- 12 toilets
- Series / Variants
- V6D (1)

What does KEORH V6D Benchmark & Water Budget show?
Flow standing: KEORH V6D operates at 1.28 gpf (standard 1.28 gpf WaterSense tier), #595 of 3,875 rated single-flush models; tied with 3,280 other rated single-flush models at the 1.28 gpf median, cutting 20.0% off EPAct 1992 (1.6 gpf).
For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.28 gpf bowl (Pressure Assist flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.
Brand breadth: KEORH holds 12 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~12,156 gallons/yr—roughly $97/yr in low-tariff towns ($8/1k gal), $134/yr at national averages ($11/1k gal), or $219/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: AIMLER W.C - AC-039 / TANK - AC-040 (1.28 gpf) and American Standard 2568128 (1.28 gpf).
How does KEORH V6D compare to EPAct 1992 and legacy gpf rates?
Tested at 1.28 gpf, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (1.6 gpf) and pre-1994 legacy units (3.5 gpf).
What floor flatness and flange clearances pair with KEORH V6D?
Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.
Which EPA WaterSense test specs apply to KEORH V6D?
Certified EPA WaterSense records for KEORH V6D verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | KEORH (12 certified) | EPA WaterSense Partner |
| Model Number / Series | V6D | Certified Series (1 finish variants) |
| Rated Consumption | 1.28 gpf | Category median 1.28 gpf (n=3,875 rated) |
| Flush / Valve Architecture | Single / Pressure Assist | Verify rough-in & supply pressure |
How much water and money can KEORH V6D save each year?
Household projections below calculate KEORH V6D annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 2,336 gal | 584 gal | 4,052 gal (~$45) |
| 2 Occupants | 4,672 gal | 1,168 gal | 8,104 gal (~$89) |
| 3 Occupants | 7,008 gal | 1,752 gal | 12,156 gal (~$97–$219) |
| 4 Occupants | 9,344 gal | 2,336 gal | 16,208 gal (~$178) |
Which EPA WaterSense fixtures match KEORH V6D?
Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.
| Peer Brand & Model | Rated GPF (Delta) | Flush / Model Detail |
|---|---|---|
| AIMLER W.C - AC-039 / TANK... | 1.28 gpf (Same flow) | Single / Gravity |
| American Standard 2568128 | 1.28 gpf (Same flow) | Single / Gravity |
| American Standard 3332128DISP | 1.28 gpf (Same flow) | Single / Gravity |
| Aquasource 810485/T802M | 1.28 gpf (Same flow) | Single / Gravity |
| Bathroom Anywhere 42832 | 1.28 gpf (Same flow) | Single / Gravity |
How much does KEORH V6D save at your local water rate?
Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.
When does KEORH V6D fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering KEORH V6D.
Limitations & Who Should Skip
- Legacy cast-iron drain has reverse slope (camera scope before <1.28 gpf drop)
Best-Fit Homeowner Profiles
- Recommended when: Claiming utility rebates across 200 U.S. WaterSense programs
- Target scenario: Lowering household draw to 2,336 gal/person/yr
What key rules and numbers govern KEORH V6D?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting KEORH V6D.
When does switching to KEORH V6D (1.28 gpf) require a drain inspection?
Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.28 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.
How do 133 WaterSense rebate programs treat KEORH V6D?
Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like KEORH V6D, itemized purchase invoices, and residential installation addresses.
How does KEORH V6D perform relative to the EPA WaterSense category median?
Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.28 gpf, KEORH V6D sits equal to the category median while clearing federal WaterSense caps.
How much does a 3-resident family save yearly switching to KEORH V6D?
At $11 per 1,000 gallons, a 3-person household conserving 12,153 gallons/yr with KEORH V6D trims roughly $134 annually off water and sewer utility bills.
What closet flange and side-wall clearances apply to KEORH V6D?
IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).
How is EPA WaterSense performance tested beyond raw gpf flow caps?
EPA WaterSense certification pairs the 1.28 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.
Does installing KEORH V6D require a municipal plumbing permit?
Like-for-like swaps using KEORH V6D on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
What annual gallon reduction does KEORH V6D achieve over older plumbing?
Testing at 1.28 gpf, KEORH V6D uses 63.4% less water than 3.5 gpf pre-1994 models (20.0% below 1.6 gpf EPAct), conserving 4,051 gallons per resident each year.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)