Skip to main content
Grant Estimator

KEORH V9B WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · KEORH (1 SKU)
Verified Specification Summary

Operating at 1.28 gpf, the KEORH V9B toilet beats 1992 EPAct rules (1.6 gpf) by 20.0% (#595 of 3,875 rated single-flush models (out of 6,793 certified toilets); tied with 3,280 other rated single-flush models at the 1.28 gpf median), saving a 3-resident home ~12,156 gallons annually compared to 3.5 gpf legacy hardware. Compare EPA WaterSense certified flow metrics for KEORH V9B WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.28 gpf
vs. EPAct 1992
-20.0% (1.6 gpf)
Annual Draw (1 Pers.)
2,336 gal/yr
Annual Saved vs. Legacy
4,052 gal/person
Brand EPA Count
12 toilets
Series / Variants
V9B (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does KEORH V9B Benchmark & Water Budget show?

WaterSense benchmark: KEORH series V9B verifies 1.28 gpf delivery, scoring 20.0% leaner than EPAct 1992 (1.6 gpf) at #595 of 3,875 rated single-flush models; tied with 3,280 other rated single-flush models at the 1.28 gpf median.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.28 gpf bowl (Pressure Assist flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: KEORH holds 12 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~12,156 gallons/yr—roughly $97/yr in low-tariff towns ($8/1k gal), $134/yr at national averages ($11/1k gal), or $219/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: AIMLER W.C - AC-039 / TANK - AC-040 (1.28 gpf) and American Standard 2568128 (1.28 gpf).

How much leaner is KEORH V9B than pre-1994 3.5 gpf plumbing?

Flow distribution bars contrast KEORH V9B (1.28 gpf) directly with the 1.28 gpf WaterSense median and 3.5 gpf older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): V9B: 1.28; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)V9B: 1.28V9B1.28EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.28 gpf: 1.28 gpf (100th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.28 gpf: 1.28 gpf (P100)

Which framing and flange tolerances matter before installing KEORH V9B?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does KEORH V9B compare to WaterSense category caps?

Each specification row below documents KEORH V9B tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share KEORH (12 certified) EPA WaterSense Partner
Model Number / Series V9B Certified Series (1 finish variants)
Rated Consumption 1.28 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Pressure Assist Verify rough-in & supply pressure

How many gallons per year does KEORH V9B cut?

Calculated annual water budgets below quantify KEORH V9B savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for KEORH V9B (1.28 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,336 gal584 gal4,052 gal (~$45)
2 Occupants4,672 gal1,168 gal8,104 gal (~$89)
3 Occupants7,008 gal1,752 gal12,156 gal (~$97–$219)
4 Occupants9,344 gal2,336 gal16,208 gal (~$178)

Which competing models share KEORH V9B flow tier?

Review five peer WaterSense units matching KEORH V9B conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
AIMLER W.C - AC-039 / TANK... 1.28 gpf (Same flow) Single / Gravity
American Standard 2568128 1.28 gpf (Same flow) Single / Gravity
American Standard 3332128DISP 1.28 gpf (Same flow) Single / Gravity
Aquasource 810485/T802M 1.28 gpf (Same flow) Single / Gravity
Bathroom Anywhere 42832 1.28 gpf (Same flow) Single / Gravity

Can you estimate KEORH V9B payback in your home?

Test how many gallons and dollars KEORH V9B saves each year by entering your household residents and local water-sewer rate below.

When does KEORH V9B fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering KEORH V9B.

Limitations & Who Should Skip

  • Unvented branch drain causing slow bowl clear

Best-Fit Homeowner Profiles

  • Recommended when: Upgrading 3.5 gpf fixtures for 63.4% water reduction
  • Target scenario: Matching KEORH SKU V9B certification on rebate forms

How do federal and code standards apply to KEORH V9B?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for KEORH V9B.

How do 133 WaterSense rebate programs treat KEORH V9B?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like KEORH V9B, itemized purchase invoices, and residential installation addresses.

How does KEORH V9B perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.28 gpf, KEORH V9B sits equal to the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to KEORH V9B?

At $11 per 1,000 gallons, a 3-person household conserving 12,153 gallons/yr with KEORH V9B trims roughly $134 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to KEORH V9B?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.28 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing KEORH V9B require a municipal plumbing permit?

Like-for-like swaps using KEORH V9B on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does KEORH V9B achieve over older plumbing?

Testing at 1.28 gpf, KEORH V9B uses 63.4% less water than 3.5 gpf pre-1994 models (20.0% below 1.6 gpf EPAct), conserving 4,051 gallons per resident each year.

When does switching to KEORH V9B (1.28 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.28 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories