Skip to main content
Grant Estimator

Mansfield 5388CTK WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Summit Rd (1 SKU)
Verified Specification Summary

Homeowners upgrading older 3.5 gpf plumbing to Mansfield 5388CTK (1.28 gpf, #595 of 3,875 rated single-flush models (out of 6,793 certified toilets); tied with 3,280 other rated single-flush models at the 1.28 gpf median) cut 63.4% off legacy draw, conserving ~12,156 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Mansfield 5388CTK WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.28 gpf
vs. EPAct 1992
-20.0% (1.6 gpf)
Annual Draw (1 Pers.)
2,336 gal/yr
Annual Saved vs. Legacy
4,052 gal/person
Brand EPA Count
74 toilets
Series / Variants
5388CTK (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Mansfield 5388CTK Benchmark & Water Budget show?

Laboratory testing places Mansfield 5388CTK (Summit Rd) at 1.28 gpf (standard 1.28 gpf WaterSense tier), saving 20.0% vs. EPAct 1992 (1.6 gpf) while ranking #595 of 3,875 rated single-flush models; tied with 3,280 other rated single-flush models at the 1.28 gpf median. Bowl 388 / Tank 387.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.28 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Mansfield holds 74 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~12,156 gallons/yr—roughly $97/yr in low-tariff towns ($8/1k gal), $134/yr at national averages ($11/1k gal), or $219/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: AIMLER W.C - AC-039 / TANK - AC-040 (1.28 gpf) and American Standard 2568128 (1.28 gpf).

How do federal gpf limits contrast with Mansfield 5388CTK tested flow?

Each bar isolates Mansfield 5388CTK (1.28 gpf) relative to the EPA cap, federal EPAct 1992 standard (1.6 gpf), and pre-1994 draw.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): 5388CTK: 1.28; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)5388CTK: 1.285388CTK1.28EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.28 gpf: 1.28 gpf (100th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.28 gpf: 1.28 gpf (P100)

How does wet-zone tile prep interact with Mansfield 5388CTK rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What plumbing standards accompany Mansfield 5388CTK installation?

Verify Mansfield 5388CTK EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Mansfield (74 certified) EPA WaterSense Partner
Model Number / Series 5388CTK Summit Rd (1 finish variants)
Rated Consumption 1.28 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

What household water budget fits Mansfield 5388CTK?

Annual consumption rows below translate Mansfield 5388CTK certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for Mansfield 5388CTK (1.28 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,336 gal584 gal4,052 gal (~$45)
2 Occupants4,672 gal1,168 gal8,104 gal (~$89)
3 Occupants7,008 gal1,752 gal12,156 gal (~$97–$219)
4 Occupants9,344 gal2,336 gal16,208 gal (~$178)

Where can buyers find alternatives to Mansfield 5388CTK?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
AIMLER W.C - AC-039 / TANK... 1.28 gpf (Same flow) Single / Gravity
American Standard 2568128 1.28 gpf (Same flow) Single / Gravity
American Standard 3332128DISP 1.28 gpf (Same flow) Single / Gravity
Aquasource 810485/T802M 1.28 gpf (Same flow) Single / Gravity
Bathroom Anywhere 42832 1.28 gpf (Same flow) Single / Gravity

What annual bill drop does Mansfield 5388CTK achieve for your family?

Calculate annual gallons conserved and dollar savings for Mansfield 5388CTK using your exact occupant count and utility tariff without submitting personal info.

What plumbing or duct constraints rule out Mansfield 5388CTK?

Compare where Mansfield 5388CTK excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Building drain lacks 1/4 in/ft slope for reduced flush carry

Best-Fit Homeowner Profiles

  • Homeowner profile: Meeting 1.6 gpf federal & stricter WaterSense caps
  • Suited to: Targeting ~$134/yr utility savings (3-person home)

Which code checks and cost facts matter for Mansfield 5388CTK?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Mansfield 5388CTK.

When does switching to Mansfield 5388CTK (1.28 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.28 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

How do 133 WaterSense rebate programs treat Mansfield 5388CTK?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Mansfield 5388CTK, itemized purchase invoices, and residential installation addresses.

How does Mansfield 5388CTK perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.28 gpf, Mansfield 5388CTK sits equal to the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Mansfield 5388CTK?

At $11 per 1,000 gallons, a 3-person household conserving 12,153 gallons/yr with Mansfield 5388CTK trims roughly $134 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to Mansfield 5388CTK?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.28 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Mansfield 5388CTK require a municipal plumbing permit?

Like-for-like swaps using Mansfield 5388CTK on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 3.5 gpf fixture to Mansfield 5388CTK at 1.28 gpf?

Swapping a 3.5 gpf unit for Mansfield 5388CTK slashes water draw 63.4% (4,051 gal/person/yr), beating 1.6 gpf federal EPAct standards by 20.0%.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories