Skip to main content
Grant Estimator

Niagara N2310 WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Power-One TM (1 SKU)
Verified Specification Summary

Listed in EPA WaterSense files at 1.28 gpf, Niagara N2310 achieves #595 of 3,875 rated single-flush models (out of 6,793 certified toilets); tied with 3,280 other rated single-flush models at the 1.28 gpf median and lowers household water use ~12,156 gal/yr (3 residents) against pre-1994 3.5 gpf fixtures. Compare EPA WaterSense certified flow metrics for Niagara N2310 WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.28 gpf
vs. EPAct 1992
-20.0% (1.6 gpf)
Annual Draw (1 Pers.)
2,336 gal/yr
Annual Saved vs. Legacy
4,052 gal/person
Brand EPA Count
160 toilets
Series / Variants
N2310 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Niagara N2310 Benchmark & Water Budget show?

Certified discharge for Niagara N2310 (Power-One TM) measures 1.28 gpf (standard 1.28 gpf WaterSense tier), standing #595 of 3,875 rated single-flush models; tied with 3,280 other rated single-flush models at the 1.28 gpf median against the 1.6 gpf standard. Bowl N2310B / Tank N2310T.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.28 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Niagara holds 160 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~12,156 gallons/yr—roughly $97/yr in low-tariff towns ($8/1k gal), $134/yr at national averages ($11/1k gal), or $219/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Tucson - Tucson Water (AZ) list active rebates among 200 U.S. programs. Closest alternatives: AIMLER W.C - AC-039 / TANK - AC-040 (1.28 gpf) and American Standard 2568128 (1.28 gpf).

Does Niagara N2310 beat the 1.28 gpf WaterSense toilet median?

Certified at 1.28 gpf, Niagara N2310 sits well under EPAct 1992 limits (1.6 gpf) across 6,793 EPA-registered toilets.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): N2310: 1.28; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)N2310: 1.28N23101.28EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.28 gpf: 1.28 gpf (100th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.28 gpf: 1.28 gpf (P100)

Why check closet flange height and L/360 stiffness around Niagara N2310?

Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Where does Niagara N2310 fit in EPA WaterSense files?

Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for Niagara N2310.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Niagara (160 certified) EPA WaterSense Partner
Model Number / Series N2310 Power-One TM (1 finish variants)
Rated Consumption 1.28 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

Does Niagara N2310 lower water bills for larger households?

Review computed annual water totals for 1 to 4 residents comparing Niagara N2310 certified consumption with older pre-1994 residential plumbing hardware.

Computed annual water savings for Niagara N2310 (1.28 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,336 gal584 gal4,052 gal (~$45)
2 Occupants4,672 gal1,168 gal8,104 gal (~$89)
3 Occupants7,008 gal1,752 gal12,156 gal (~$97–$219)
4 Occupants9,344 gal2,336 gal16,208 gal (~$178)

How do similar WaterSense brands compare with Niagara N2310?

Comparable certified models listed below share Niagara N2310 category standards while offering alternative brand warranties and rough-in configurations.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
AIMLER W.C - AC-039 / TANK... 1.28 gpf (Same flow) Single / Gravity
American Standard 2568128 1.28 gpf (Same flow) Single / Gravity
American Standard 3332128DISP 1.28 gpf (Same flow) Single / Gravity
Aquasource 810485/T802M 1.28 gpf (Same flow) Single / Gravity
Bathroom Anywhere 42832 1.28 gpf (Same flow) Single / Gravity

How do local water rates change Niagara N2310 savings?

Use the local browser estimator below with your city water-sewer rate and household size to quantify Niagara N2310 yearly utility impact.

Who should not install Niagara N2310 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Niagara N2310 for residential use.

Limitations & Who Should Skip

  • Legacy cast-iron drain has reverse slope (camera scope before <1.28 gpf drop)

Best-Fit Homeowner Profiles

  • Ideal fit: Claiming utility rebates across 200 U.S. WaterSense programs
  • Primary match: Lowering household draw to 2,336 gal/person/yr

What should homeowners verify first about Niagara N2310?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Niagara N2310.

Is Niagara N2310 leaner than typical WaterSense toilet models?

Compared with the 1.28 gpf WaterSense toilet median, Niagara N2310's 1.28 gpf rating places it equal to category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with Niagara N2310?

Upgrading a 3.5 gpf legacy fixture to Niagara N2310 saves ~12,153 gallons yearly for three occupants, about $134/yr at $11 per 1,000 gallons combined water and sewer.

What closet flange and side-wall clearances apply to Niagara N2310?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.28 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Niagara N2310 require a municipal plumbing permit?

Like-for-like swaps using Niagara N2310 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How much water does Niagara N2310 save compared with EPAct 1992 and pre-1994 fixtures?

Rated at 1.28 gpf, Niagara N2310 cuts 20.0% below the 1.6 gpf EPAct 1992 ceiling and 63.4% under 3.5 gpf legacy units, saving 4,051 gal/person/yr (584 vs EPAct).

Who should NOT install Niagara N2310 without checking house plumbing first?

Homes with aging cast-iron drains, flat slopes under 1/4 in/ft, or pipe bellies should camera-check waste carry before dropping from 3.5 gpf bowls to 1.28 gpf high-efficiency flushing.

Can homeowners claim utility rebates when installing Niagara N2310?

Because Niagara N2310 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories