Skip to main content
Grant Estimator

Niagara N7716R-17 WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Niagara (1 SKU)
Verified Specification Summary

Homeowners upgrading older 3.5 gpf plumbing to Niagara N7716R-17 (0.8 gpf, #4 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 3.2% of 3,875 rated single-flush models, lower-flow than 96.8% of rated single-flush models) cut 77.1% off legacy draw, conserving ~14,784 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Niagara N7716R-17 WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
0.8 gpf
vs. EPAct 1992
-50.0% (1.6 gpf)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
4,928 gal/person
Brand EPA Count
160 toilets
Series / Variants
N7716R-17 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Niagara N7716R-17 Benchmark & Water Budget show?

Laboratory testing places Niagara N7716R-17 at 0.8 gpf (ultra-low sub-1.1 gpf tier), saving 50.0% vs. EPAct 1992 (1.6 gpf) while ranking #4 of 3,875 rated single-flush models; most water-efficient 3.2% of 3,875 rated single-flush models, lower-flow than 96.8% of rated single-flush models (0.48 gpf lower-flow than the 1.28 gpf median). Bowl N7716RB-17 / Tank N7714T.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 0.8 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Niagara holds 160 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~14,784 gallons/yr—roughly $118/yr in low-tariff towns ($8/1k gal), $163/yr at national averages ($11/1k gal), or $266/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: Aflush/Waso A2001EP (0.8 gpf) and American Standard 250AA808 (0.8 gpf).

How do federal gpf limits contrast with Niagara N7716R-17 tested flow?

Each bar isolates Niagara N7716R-17 (0.80 gpf) relative to the EPA cap, federal EPAct 1992 standard (1.6 gpf), and pre-1994 draw.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): N7716R-17: 0.80; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)N7716R-17: 0.80N7716R-170.80EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 0.8 gpf: 0.8 gpf (3rd percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf0.8 gpf: 0.8 gpf (P3)

How does wet-zone tile prep interact with Niagara N7716R-17 rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What plumbing standards accompany Niagara N7716R-17 installation?

Verify Niagara N7716R-17 EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Niagara (160 certified) EPA WaterSense Partner
Model Number / Series N7716R-17 Certified Series (1 finish variants)
Rated Consumption 0.8 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

What household water budget fits Niagara N7716R-17?

Annual consumption rows below translate Niagara N7716R-17 certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for Niagara N7716R-17 (0.8 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,460 gal4,928 gal (~$54)
2 Occupants2,920 gal2,920 gal9,856 gal (~$108)
3 Occupants4,380 gal4,380 gal14,784 gal (~$118–$266)
4 Occupants5,840 gal5,840 gal19,712 gal (~$217)

Where can buyers find alternatives to Niagara N7716R-17?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
Aflush/Waso A2001EP 0.8 gpf (Same flow) Single / Gravity
American Standard 250AA808 0.8 gpf (Same flow) Single / Gravity
American Standard 250AA809 0.8 gpf (Same flow) Single / Gravity
American Standard 251AA808 0.8 gpf (Same flow) Single / Gravity
American Standard 251AA809 0.8 gpf (Same flow) Single / Gravity

What annual bill drop does Niagara N7716R-17 achieve for your family?

Calculate annual gallons conserved and dollar savings for Niagara N7716R-17 using your exact occupant count and utility tariff without submitting personal info.

Where should contractors skip Niagara N7716R-17 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Niagara N7716R-17 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Building drain lacks 1/4 in/ft slope for reduced flush carry

Best-Fit Homeowner Profiles

  • Choose this if: Meeting 1.6 gpf federal & stricter WaterSense caps
  • Works well for: Targeting ~$163/yr utility savings (3-person home)

Which code checks and cost facts matter for Niagara N7716R-17?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Niagara N7716R-17.

What annual dollar savings can a 3-person home expect with Niagara N7716R-17?

Upgrading a 3.5 gpf legacy fixture to Niagara N7716R-17 saves ~14,784 gallons yearly for three occupants, about $163/yr at $11 per 1,000 gallons combined water and sewer.

What closet flange and side-wall clearances apply to Niagara N7716R-17?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 0.8 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Niagara N7716R-17 require a municipal plumbing permit?

Like-for-like swaps using Niagara N7716R-17 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How many gallons per person does Niagara N7716R-17 save annually?

Each resident saves ~4,928 gallons yearly (77.1% drop) replacing a 3.5 gpf fixture with Niagara N7716R-17 (0.8 gpf), or 1,460 gal/yr versus 1.6 gpf EPAct baselines.

Who should NOT install Niagara N7716R-17 without checking house plumbing first?

Homes with aging cast-iron drains, flat slopes under 1/4 in/ft, or pipe bellies should camera-check waste carry before dropping from 3.5 gpf bowls to 0.8 gpf high-efficiency flushing.

Can homeowners claim utility rebates when installing Niagara N7716R-17?

Because Niagara N7716R-17 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is Niagara N7716R-17 leaner than typical WaterSense toilet models?

Compared with the 1.28 gpf WaterSense toilet median, Niagara N7716R-17's 0.8 gpf rating places it below category norms inside EPA conservation limits.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories