Skip to main content
Grant Estimator

Niagara N772715E WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Stealth (8 SKUs)
Verified Specification Summary

Operating at 0.8 gpf, the Niagara N772715E toilet beats 1992 EPAct rules (1.6 gpf) by 50.0% (#4 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 3.2% of 3,875 rated single-flush models, lower-flow than 96.8% of rated single-flush models), saving a 3-resident home ~14,784 gallons annually compared to 3.5 gpf legacy hardware. Compare EPA WaterSense certified flow metrics for Niagara N772715E WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
0.8 gpf
vs. EPAct 1992
-50.0% (1.6 gpf)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
4,928 gal/person
Brand EPA Count
160 toilets
Series / Variants
N772715E (8)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Niagara N772715E Benchmark & Water Budget show?

WaterSense benchmark: Niagara series N772715E (Stealth) verifies 0.8 gpf delivery, scoring 50.0% leaner than EPAct 1992 (1.6 gpf) at #4 of 3,875 rated single-flush models; most water-efficient 3.2% of 3,875 rated single-flush models, lower-flow than 96.8% of rated single-flush models (0.48 gpf lower-flow than the 1.28 gpf median). Bowl N7727EB / Tank N7715T.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 0.8 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Niagara holds 160 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~14,784 gallons/yr—roughly $118/yr in low-tariff towns ($8/1k gal), $163/yr at national averages ($11/1k gal), or $266/yr in high-rate cities ($18/1k gal). Regional utilities such as Liberty Utilities - Arizona (AZ) list active rebates among 200 U.S. programs. Closest alternatives: Aflush/Waso A2001EP (0.8 gpf) and American Standard 250AA808 (0.8 gpf).

How much leaner is Niagara N772715E than pre-1994 3.5 gpf plumbing?

Flow distribution bars contrast Niagara N772715E (0.80 gpf) directly with the 1.28 gpf WaterSense median and 3.5 gpf older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): N772715E: 0.80; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)N772715E: 0.80N772715E0.80EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 0.8 gpf: 0.8 gpf (3rd percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf0.8 gpf: 0.8 gpf (P3)

Which framing and flange tolerances matter before installing Niagara N772715E?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does Niagara N772715E compare to WaterSense category caps?

Each specification row below documents Niagara N772715E tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Niagara (160 certified) EPA WaterSense Partner
Model Number / Series N772715E Stealth (8 finish variants)
Rated Consumption 0.8 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

Which 8 finish and trim SKUs share the Niagara N772715E WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 8 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Niagara N772715E (8 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
N772715E0.8 gpfStealth
N772614R0.8 gpfStealth
N772615R0.8 gpfStealth
N77160.8 gpfStealth
N77170.8 gpfStealth
77001RWHAI10.8 gpfStealth
77001WHCO10.8 gpfStealth
77000WHAI10.8 gpfStealth

How many gallons per year does Niagara N772715E cut?

Calculated annual water budgets below quantify Niagara N772715E savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for Niagara N772715E (0.8 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,460 gal4,928 gal (~$54)
2 Occupants2,920 gal2,920 gal9,856 gal (~$108)
3 Occupants4,380 gal4,380 gal14,784 gal (~$118–$266)
4 Occupants5,840 gal5,840 gal19,712 gal (~$217)

Which competing models share Niagara N772715E flow tier?

Review five peer WaterSense units matching Niagara N772715E conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
Aflush/Waso A2001EP 0.8 gpf (Same flow) Single / Gravity
American Standard 250AA808 0.8 gpf (Same flow) Single / Gravity
American Standard 250AA809 0.8 gpf (Same flow) Single / Gravity
American Standard 251AA808 0.8 gpf (Same flow) Single / Gravity
American Standard 251AA809 0.8 gpf (Same flow) Single / Gravity

Can you estimate Niagara N772715E payback in your home?

Test how many gallons and dollars Niagara N772715E saves each year by entering your household residents and local water-sewer rate below.

What plumbing or duct constraints rule out Niagara N772715E?

Compare where Niagara N772715E excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Unvented branch drain causing slow bowl clear

Best-Fit Homeowner Profiles

  • Homeowner profile: Upgrading 3.5 gpf fixtures for 77.1% water reduction
  • Suited to: Matching Niagara SKU N772715E certification on rebate forms

How do federal and code standards apply to Niagara N772715E?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Niagara N772715E.

Why upgrade a 3.5 gpf fixture to Niagara N772715E at 0.8 gpf?

Swapping a 3.5 gpf unit for Niagara N772715E slashes water draw 77.1% (4,928 gal/person/yr), beating 1.6 gpf federal EPAct standards by 50.0%.

When does switching to Niagara N772715E (0.8 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 0.8 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

How do 133 WaterSense rebate programs treat Niagara N772715E?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Niagara N772715E, itemized purchase invoices, and residential installation addresses.

How does Niagara N772715E perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 0.8 gpf, Niagara N772715E sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Niagara N772715E?

At $11 per 1,000 gallons, a 3-person household conserving 14,784 gallons/yr with Niagara N772715E trims roughly $163 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to Niagara N772715E?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 0.8 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Niagara N772715E require a municipal plumbing permit?

Like-for-like swaps using Niagara N772715E on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories