Skip to main content
Grant Estimator

Niagara N7799 WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Niagara (1 SKU)
Verified Specification Summary

The Niagara N7799 is an EPA WaterSense toilet certified at 0.95 gpf, 40.6% below EPAct 1992 (1.6 gpf) and #163 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 4.2% of 3,875 rated single-flush models, lower-flow than 95.8% of rated single-flush models. A 3-person household saves ~13,962 gallons/yr replacing a 3.5 gpf legacy fixture.

Certified Flow
0.95 gpf
vs. EPAct 1992
-40.6% (1.6 gpf)
Annual Draw (1 Pers.)
1,734 gal/yr
Annual Saved vs. Legacy
4,654 gal/person
Brand EPA Count
160 toilets
Series / Variants
N7799 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Niagara N7799 Benchmark & Water Budget show?

Flow standing: Niagara N7799 operates at 0.95 gpf (ultra-low sub-1.1 gpf tier), #163 of 3,875 rated single-flush models; most water-efficient 4.2% of 3,875 rated single-flush models, lower-flow than 95.8% of rated single-flush models (0.33 gpf lower-flow than the 1.28 gpf median), cutting 40.6% off EPAct 1992 (1.6 gpf). Bowl N7799 / Tank N7799T.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 0.95 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Niagara holds 160 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~13,962 gallons/yr—roughly $112/yr in low-tariff towns ($8/1k gal), $154/yr at national averages ($11/1k gal), or $251/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: Hennessy & Hinchcliffe N7799-HH (0.95 gpf) and Contrac 4710BOXU (0.92 gpf).

How does Niagara N7799 compare to EPAct 1992 and legacy gpf rates?

Tested at 0.95 gpf, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (1.6 gpf) and pre-1994 legacy units (3.5 gpf).

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): N7799: 0.95; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)N7799: 0.95N77990.95EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 0.95 gpf: 0.95 gpf (4th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf0.95 gpf: 0.95 gpf (P4)

What floor flatness and flange clearances pair with Niagara N7799?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which EPA WaterSense test specs apply to Niagara N7799?

Certified EPA WaterSense records for Niagara N7799 verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Niagara (160 certified) EPA WaterSense Partner
Model Number / Series N7799 Certified Series (1 finish variants)
Rated Consumption 0.95 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

How much water and money can Niagara N7799 save each year?

Household projections below calculate Niagara N7799 annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for Niagara N7799 (0.95 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,734 gal1,186 gal4,654 gal (~$51)
2 Occupants3,468 gal2,372 gal9,308 gal (~$102)
3 Occupants5,202 gal3,558 gal13,962 gal (~$112–$251)
4 Occupants6,936 gal4,744 gal18,616 gal (~$205)

Which EPA WaterSense fixtures match Niagara N7799?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
Hennessy & Hinchcliffe N7799-HH 0.95 gpf (Same flow) Single / Gravity
Contrac 4710BOXU 0.92 gpf (-0.03) Single / Gravity
PERSN GF-A016S 0.92 gpf (-0.03) Single / Gravity
PERSN GF-A018S 0.92 gpf (-0.03) Single / Gravity
PERSN GF-T0102S 0.92 gpf (-0.03) Single / Gravity

How much does Niagara N7799 save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

When does Niagara N7799 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Niagara N7799.

Limitations & Who Should Skip

  • Legacy cast-iron drain has reverse slope (camera scope before <1.28 gpf drop)

Best-Fit Homeowner Profiles

  • Recommended when: Claiming utility rebates across 200 U.S. WaterSense programs
  • Target scenario: Lowering household draw to 1,734 gal/person/yr

What key rules and numbers govern Niagara N7799?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Niagara N7799.

How do 133 WaterSense rebate programs treat Niagara N7799?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Niagara N7799, itemized purchase invoices, and residential installation addresses.

How does Niagara N7799 perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 0.95 gpf, Niagara N7799 sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Niagara N7799?

At $11 per 1,000 gallons, a 3-person household conserving 13,962 gallons/yr with Niagara N7799 trims roughly $154 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to Niagara N7799?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 0.95 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Niagara N7799 require a municipal plumbing permit?

Like-for-like swaps using Niagara N7799 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does Niagara N7799 achieve over older plumbing?

Testing at 0.95 gpf, Niagara N7799 uses 72.9% less water than 3.5 gpf pre-1994 models (40.6% below 1.6 gpf EPAct), conserving 4,654 gallons per resident each year.

When does switching to Niagara N7799 (0.95 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 0.95 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories