Skip to main content
Grant Estimator

Sterling 402311 WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Valton (3 SKUs)
Verified Specification Summary

Homeowners upgrading older 3.5 gpf plumbing to Sterling 402311 (1.28 gpf, #595 of 3,875 rated single-flush models (out of 6,793 certified toilets); tied with 3,280 other rated single-flush models at the 1.28 gpf median) cut 63.4% off legacy draw, conserving ~12,156 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Sterling 402311 WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.28 gpf
vs. EPAct 1992
-20.0% (1.6 gpf)
Annual Draw (1 Pers.)
2,336 gal/yr
Annual Saved vs. Legacy
4,052 gal/person
Brand EPA Count
31 toilets
Series / Variants
402311 (3)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Sterling 402311 Benchmark & Water Budget show?

Laboratory testing places Sterling 402311 (Valton) at 1.28 gpf (standard 1.28 gpf WaterSense tier), saving 20.0% vs. EPAct 1992 (1.6 gpf) while ranking #595 of 3,875 rated single-flush models; tied with 3,280 other rated single-flush models at the 1.28 gpf median. Bowl 403377 / Tank 404501.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.28 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Sterling holds 31 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~12,156 gallons/yr—roughly $97/yr in low-tariff towns ($8/1k gal), $134/yr at national averages ($11/1k gal), or $219/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: AIMLER W.C - AC-039 / TANK - AC-040 (1.28 gpf) and American Standard 2568128 (1.28 gpf).

How do federal gpf limits contrast with Sterling 402311 tested flow?

Each bar isolates Sterling 402311 (1.28 gpf) relative to the EPA cap, federal EPAct 1992 standard (1.6 gpf), and pre-1994 draw.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): 402311: 1.28; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)402311: 1.284023111.28EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.28 gpf: 1.28 gpf (100th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.28 gpf: 1.28 gpf (P100)

How does wet-zone tile prep interact with Sterling 402311 rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What plumbing standards accompany Sterling 402311 installation?

Verify Sterling 402311 EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Sterling (31 certified) EPA WaterSense Partner
Model Number / Series 402311 Valton (3 finish variants)
Rated Consumption 1.28 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

Which 3 finish and trim SKUs share the Sterling 402311 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 3 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Sterling 402311 (3 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
402311-xxyyy-**1.28 gpfValton
402313-xxyyy-**1.28 gpfValton
402312-xxyyy-**1.28 gpfValton

What household water budget fits Sterling 402311?

Annual consumption rows below translate Sterling 402311 certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for Sterling 402311 (1.28 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,336 gal584 gal4,052 gal (~$45)
2 Occupants4,672 gal1,168 gal8,104 gal (~$89)
3 Occupants7,008 gal1,752 gal12,156 gal (~$97–$219)
4 Occupants9,344 gal2,336 gal16,208 gal (~$178)

Where can buyers find alternatives to Sterling 402311?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
AIMLER W.C - AC-039 / TANK... 1.28 gpf (Same flow) Single / Gravity
American Standard 2568128 1.28 gpf (Same flow) Single / Gravity
American Standard 3332128DISP 1.28 gpf (Same flow) Single / Gravity
Aquasource 810485/T802M 1.28 gpf (Same flow) Single / Gravity
Bathroom Anywhere 42832 1.28 gpf (Same flow) Single / Gravity

What annual bill drop does Sterling 402311 achieve for your family?

Calculate annual gallons conserved and dollar savings for Sterling 402311 using your exact occupant count and utility tariff without submitting personal info.

What plumbing or duct constraints rule out Sterling 402311?

Compare where Sterling 402311 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Building drain lacks 1/4 in/ft slope for reduced flush carry

Best-Fit Homeowner Profiles

  • Homeowner profile: Meeting 1.6 gpf federal & stricter WaterSense caps
  • Suited to: Targeting ~$134/yr utility savings (3-person home)

Which code checks and cost facts matter for Sterling 402311?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Sterling 402311.

How much does a 3-resident family save yearly switching to Sterling 402311?

At $11 per 1,000 gallons, a 3-person household conserving 12,153 gallons/yr with Sterling 402311 trims roughly $134 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to Sterling 402311?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.28 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Sterling 402311 require a municipal plumbing permit?

Like-for-like swaps using Sterling 402311 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 3.5 gpf fixture to Sterling 402311 at 1.28 gpf?

Swapping a 3.5 gpf unit for Sterling 402311 slashes water draw 63.4% (4,051 gal/person/yr), beating 1.6 gpf federal EPAct standards by 20.0%.

When does switching to Sterling 402311 (1.28 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.28 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

How do 133 WaterSense rebate programs treat Sterling 402311?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Sterling 402311, itemized purchase invoices, and residential installation addresses.

How does Sterling 402311 perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.28 gpf, Sterling 402311 sits equal to the category median while clearing federal WaterSense caps.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories